Construct validity testing of a laparoscopic surgical simulator

被引:121
|
作者
McDougall, EM [1 ]
Corica, FA [1 ]
Boker, JR [1 ]
Sala, LG [1 ]
Stoliar, G [1 ]
Borin, JF [1 ]
T Chu, F [1 ]
Clayman, RV [1 ]
机构
[1] Univ Calif Irvine, Med Ctr, Dept Urol & Family Med, Orange, CA 92868 USA
关键词
D O I
10.1016/j.jamcollsurg.2006.01.004
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: We present initial data on the construct, content, and face validity of the LAPMentor (Simbionix), virtual reality laparoscopic surgical simulator. STUDY DESIGN: Medical students (MS), residents and fellows (R/F), and experienced laparoscopic surgeons (ES), with > 30 laparoscopic cases per year (ES < 30) and those with > 30 laparoscopic cases per year (ES > 30), were tested on 9 basic skill tasks (SK) Including manipulation of 0-degree and 30-degree cameras (SKI, SK2), eye-hand coordination (SK3), clipping (SK4), grasping and clipping (SK5), two-handed maneuvers (SK6), Cutting (SK7), fulguration (SK8), and object-translocation (SK9). RESULTS: Mean MS (n = 23), R/F (n = 24), ES < 30 (n = 26), and ES > 30 (n = 30) ages were 26 years (range 21 to 32 years), 31 years (range 27 to 39 years), 49 years (range 31 to 70 years) and 47 years (range 34 to 69 years), respectively. In the lower level skill tasks (SK3, SK4, SK5, and SK6) the ES > 30, ES < 30, and R/F had similar scores, but were all substantially better than the MS scores. In the higher level skill tasks (SK7, SK8, and SK9), the ES > 30 scores tended to be better than the R/F and ES < 30, which were similar, and these, in turn, were markedly better than the MS. The ES > 30 had notably higher SK8 scores than the R/F and ES < 30, who had similar scores, and these had notably better scores than the MS. CONCLUSIONS: The noncamera skills (SK3 to 9) of the LAPMentor surgical simulator can distinguish between laparoscopically naive and ES. SK8 showed the highest level of construct validity, by accurately differentiating among the MS, R/F, ES < 30 and ES > 30.
引用
收藏
页码:779 / 787
页数:9
相关论文
共 50 条
  • [41] Construct validity of individual and summary performance metrics associated with a computer-based laparoscopic simulator
    Rivard, Justin D.
    Vergis, Ashley S.
    Unger, Bertram J.
    Hardy, Krista M.
    Andrew, Chris G.
    Gillman, Lawrence M.
    Park, Jason
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2014, 28 (06): : 1921 - 1928
  • [42] Face, content, and construct validity of the virtual immersive operating room simulator for training laparoscopic procedures
    Perez-Escamirosa, Fernando
    Areli Garcia-Cabra, Damaris
    Ricardo Ortiz-Hernandez, Jose
    Montoya-Alvarez, Salvador
    Alfredo Ruiz-Vereo, Eduardo
    Manuel Ordorica-Flores, Ricardo
    Minor-Martinez, Arturo
    Tapia-Jurado, Jesus
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (04): : 2885 - 2896
  • [43] Construct validity of individual and summary performance metrics associated with a computer-based laparoscopic simulator
    Justin D. Rivard
    Ashley S. Vergis
    Bertram J. Unger
    Krista M. Hardy
    Chris G. Andrew
    Lawrence M. Gillman
    Jason Park
    [J]. Surgical Endoscopy, 2014, 28 : 1921 - 1928
  • [44] Testing the Construct Validity of a New Laparoscopic Simulation Task for Developing Muscle Memory
    Alammari, Roa
    Kirton, Donald E.
    [J]. OBSTETRICS AND GYNECOLOGY, 2015, 126 : 44S - 44S
  • [45] RELIABILTY, FACE, CONTENT AND CONSTRUCT VALIDATION OF THE COMPUTER ASSISTED LAPAROSCOPIC SURGICAL SIMULATOR UROBOX
    Petrut, Bogdan
    Laslo, Ioana
    Tintila, Bogdan
    Codreanu, Claudiu
    Nechita, Florin
    [J]. JOURNAL OF ENDOUROLOGY, 2011, 25 : A286 - A286
  • [46] Construct validity of a physical model colonoscopy simulator
    Ooi, S. Y.
    Plooy, A. M.
    Cresp, A.
    Horswill, M. S.
    Hill, A.
    Riek, S. P.
    Burgess-Limerick, R.
    Zupanc, C.
    Wallis, G. M.
    Watson, M. O.
    Hewett, D. G.
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2010, 25 : A59 - A59
  • [47] CONSTRUCT VALIDITY AND PSYCHOLOGICAL TESTING
    RUIZ, R
    [J]. ACTA CIENTIFICA VENEZOLANA, 1970, 21 : 72 - &
  • [48] Construct validity of a simulator for myringotomy with ventilation tube insertion
    Volsky, Peter G.
    Hughley, Brian B.
    Peirce, Shayn M.
    Kesser, Bradley W.
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2009, 141 (05) : 603 - 608
  • [49] Assessment of construct validity of the endoscopic sinus surgery simulator
    Arora, H
    Uribe, J
    Ralph, W
    Zeltsan, M
    Cuellar, H
    Gallagher, A
    Fried, MP
    [J]. ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2005, 131 (03) : 217 - 221
  • [50] Face and construct validity of a novel mechanical ERCP simulator
    van der Wiel, Sophia E.
    Koch, Arjun D.
    Bruno, Marco J.