Model for the depolarizing retarder in Mueller matrix polarimetry

被引:3
|
作者
Ossikovski, Razvigor [1 ]
Arteaga, Oriol [2 ]
Garcia-Caurel, Enrique [1 ]
Hingerl, Kurt [3 ]
机构
[1] Ecole Polytech, Inst Polytech Paris, CNRS, LPICM, F-91128 Palaiseau, France
[2] Univ Barcelona, Feman Grp, IN2UB, Dept Fis Aplicada, C Marti & Franques 1, Barcelona 08030, Spain
[3] Johannes Kepler Univ Linz, Ctr Surface & Nanoanalyt, A-4040 Linz, Austria
关键词
PARTIAL COHERENCE; TURBID MEDIA; POLARIZATION; BIREFRINGENCE; DECOMPOSITION; DEPENDENCE; COMPONENTS; FORMALISM;
D O I
10.1364/JOSAA.451106
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We advance an analytical model describing the polarimetric response of a depolarizing retarder whose retardance varies spatially in magnitude or in orientation. The variation of the retarder parameters may be either of deterministic or of random nature. The model provides both the mean values and the uncertainties of the parameters. Its application is illustrated on two experimental examples, respectively covering the deterministic and the random cases. ?? 2022 Optica Publishing Group
引用
收藏
页码:873 / 882
页数:10
相关论文
共 50 条
  • [41] Characterization of cervical tissue using Mueller matrix polarimetry
    Khan, Sumera
    Qadir, Mehwish
    Khalid, Amna
    Ashraf, Sumara
    Ahmad, Iftikhar
    LASERS IN MEDICAL SCIENCE, 2023, 38 (01)
  • [42] Theoretical research of retarder phase deviation in channeled Mueller matrix spectropolarimeters
    Dai, Hu
    Li, Detian
    Yang, Bin
    Li, Yali
    OPTICS EXPRESS, 2020, 28 (09): : 13625 - 13637
  • [43] Conversion of 3 x 3 Mueller matrix to 4 x 4 Mueller matrix for non-depolarizing samples
    Swami, M. K.
    Patel, H. S.
    Gupta, P. K.
    OPTICS COMMUNICATIONS, 2013, 286 : 18 - 22
  • [44] Differential Mueller Matrix Polarimetry for Low Concentration of Glucose Sensing
    Quoc-Hung Phan
    Lo, Yu-Lung
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2017, 10251
  • [45] Mueller matrix polarimetry for characterization of skin tissue samples: A review
    Ahmad, Iftikhar
    Khaliq, Ahmar
    Iqbal, Muaz
    Khan, Shamim
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 30
  • [46] Stokes-Mueller matrix polarimetry system for glucose sensing
    Quoc-Hung Phan
    Lo, Yu-Lung
    OPTICS AND LASERS IN ENGINEERING, 2017, 92 : 120 - 128
  • [47] Hyperspectroscopic Mueller-matrix polarimeter based on channeled polarimetry
    Oka, Kazuhiko
    Sayama, Kodai
    Michida, Hiroshi
    POLARIZATION SCIENCE AND REMOTE SENSING VIII, 2017, 10407
  • [48] Mueller Coherency matrix method for contrast image in tissue polarimetry
    Arce-Diego, J. L.
    Fanjul-Velez, F.
    Samperio-Garcia, D.
    Pereda-Cubian, D.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES III, 2007, 6627
  • [49] Measurement configuration optimization for grating reconstruction by Mueller matrix polarimetry
    Chen, Xiuguo
    Liu, Shiyuan
    Zhang, Chuanwei
    Jiang, Hao
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXVII, 2013, 8681
  • [50] Mueller matrix imaging polarimetry technique for dengue fever detection
    Huy-Mai Le
    Thanh Hai Le
    Quoc Hung Phan
    Thi-Thu-Hien Pham
    OPTICS COMMUNICATIONS, 2022, 502