Determination of ammonium by using a flow system with a diffusion cell coupled to an ammonium ion-selective sensor

被引:0
|
作者
Liu, RM
Sun, BT
机构
[1] CSIRO,DIV LAND & WATER RES,CANBERRA LAB,CANBERRA,ACT 2601,AUSTRALIA
[2] LIAOCHENG TEACHERS COLL,DEPT CHEM,SHANDONG,PEOPLES R CHINA
关键词
ammonium determination; potentiometry; ammonium electrode; gas diffusion;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a flow potentiometric method for determination of ammonium at low levels. A new diffusion cell coupled to an ammonium ion electrode was used as the potentiometric detector. This method eliminates interference to the ammonium ion electrode. When the stopped-flow method is employed for the acceptor stream, ammonium ions can be accumulated in the acceptor solution in the diffusion cell, giving high selectivity and sensitivity. The lower linear value of the proposed method can reach 1 x 10(-6) mol L-1 with an accumulation time of 5 min. The method is simple, sensitive and suitable for online determination of ammonium in water samples. It has been applied to the determination of ammonium in rain water and river water, and recoveries of 95-104% were obtained. The relative standard deviation of seven replicate analyses for all samples was 1.1-2.7%.
引用
收藏
页码:1255 / 1265
页数:11
相关论文
共 50 条
  • [21] ANALYTICAL APPLICATIONS OF QUATERNARY AMMONIUM HALIDES USING ION-SELECTIVE ELECTRODES - A REVIEW
    SELIG, W
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 312 (05): : 419 - 427
  • [22] STUDIES OF QUATERNARY AMMONIUM ION INTERFERENCE ON POTASSIUM ION-SELECTIVE ELECTRODES
    LEWENSTAM, A
    ERKOLA, E
    LEHMENKUHLER, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9): : 577 - 579
  • [23] Ion-selective paper-based chromogenic strip and electrochemical sensor for the detection of ammonium ions
    Rai, Pawankumar
    Singh, Ashish K.
    Mehrotra, Srishti
    Sharma, Sandeep K.
    ELECTROCHEMISTRY COMMUNICATIONS, 2024, 165
  • [24] Ion-selective electrodes for quick on-farm determination of ammonium and potassium concentrations in pig slurry
    Piepel, Max-Frederik
    Dittert, Klaus
    Olfs, Hans-Werner
    JOURNAL OF PLANT NUTRITION AND SOIL SCIENCE, 2023, 186 (03) : 266 - 275
  • [25] DETERMINATION OF POTASSIUM IN THE PRESENCE OF AMMONIUM IN COMPLEX MINERAL FERTILIZERS USING A K+ ION-SELECTIVE ELECTRODE (EXCHANGE OF EXPERIENCE)
    LUSHCHIK, YF
    EGOROV, VV
    YAROSHENYA, NI
    INDUSTRIAL LABORATORY, 1992, 58 (04): : 325 - 327
  • [26] Determination of ammonium by potentiometry in injection in flow, coupled to a new micro device of gaseous diffusion
    Mancilla-Gamboa, Juan-Claudio
    Torres-Silva, Hector
    DYNA, 2019, 94 (03): : 313 - 317
  • [27] Synthesis of an ammonium ionophore and its application in a planar ion-selective electrode
    Benco, JS
    Nienaber, HA
    McGimpsey, WG
    ANALYTICAL CHEMISTRY, 2003, 75 (01) : 152 - 156
  • [28] A STUDY ON THE CHEMISTRY OF DODECYLAMINE HYDROCHLORIDE AQUEOUS-SOLUTIONS USING THE AMMONIUM ION-SELECTIVE ELECTRODE
    CASTRO, SH
    LASKOWSKI, JS
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1986, 63 (04) : 414 - 414
  • [29] In Situ Ammonium Profiling Using Solid-Contact Ion-Selective Electrodes in Eutrophic Lakes
    Athavale, Rohini
    Kokorite, Ilga
    Dinkel, Christian
    Bakker, Eric
    Wehrli, Bernhard
    Crespo, Gaston A.
    Brand, Andreas
    ANALYTICAL CHEMISTRY, 2015, 87 (24) : 11990 - 11997
  • [30] POTENTIOMETRIC TITRATION OF QUATERNARY AMMONIUM-SALTS BY SODIUM TETRAPHENYLBORATE USING ION-SELECTIVE ELECTRODES
    STUPIN, DY
    STRATIVNAYA, OS
    FILIPPOV, SY
    CHERNOVA, ZD
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1988, 43 (08): : 1226 - 1229