Virtual Monochromatic Dual-Energy Aortoiliac CT Angiography With Reduced Iodine Dose: A Prospective Randomized Study

被引:44
|
作者
Patina, Manuel [1 ]
Parakh, Anushri [1 ]
Lo, Grace C. [1 ]
Agrawal, Mukta [1 ]
Kambadakone, Avinash R. [1 ]
Oliveira, George R. [1 ]
Sahani, Dushyant, V [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Div Abdominal Imaging, 55 Fruit St, Boston, MA 02114 USA
关键词
abdominal aortic aneurysm; contrast medium; CT angiography; iodine; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ABDOMINAL AORTIC-ANEURYSM; DNA RADIATION-DAMAGE; ENDOVASCULAR REPAIR; ENDOLEAK DETECTION; CONTRAST AGENT; IMAGE-QUALITY; PULMONARY ANGIOGRAPHY; OPTIMIZING CONTRAST; MULTIDETECTOR CT;
D O I
10.2214/AJR.18.19935
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to assess the feasibility of performing abdominopelvic aortoiliac CT angiography (CTA) with 16.0 g of iodine contrast medium acquired with low-energy (40 and 50 keV) virtual monochromatic (VMC) images with rapid-kilovoltage-switching dual-energy CT. SUBJECTS AND METHODS. A total of 52 adults with abdominal aortoiliac aneurysm and prior 120-kVp single-energy CTA (SECTA) with 33 g iodine (standard dose) underwent follow-up dual-energy CTA (DECTA) with a 52% reduced iodine dose. Subjects were randomly assigned to a contrast medium protocol for DECTA examinations: one group (n = 26) received 16.2 g (270 mg I/mL) and the other (n = 26) received 16.0 g (320 mg I/mL). Two readers independently assessed SECTA and VMC DECTA datasets for image quality using a 5-point scale. Aortoiliac intravascular attenuation was measured, and ANOVA was used to compare measurements between VMC DECTA and SECTA images. In a subset of patients with DECTA after endovascular aortic repair, endoleak detection was evaluated on VMC images. Volume CT dose index, dose-length product, and size-specific dose estimate were compared between DECTA and SECTA. RESULTS. All DECTA examinations (n = 52) were rated diagnostic with image quality scores comparable to those of 120-kVp single-energy CTA (40 keV, 4.2-4.4; 50 keV, 4.6-4.8; SECTA, 4.4-4.5). Intravascular attenuation was uniform in all reduced-iodine DECTA examinations and was significantly higher on 40- and 50-keV images than on standard-iodine-dose SECTA images (720 +/- 125 HU and 482 +/- 82 HU vs 303 +/- 65 HU) (p < 0.01). There was no difference in intravascular attenuation between the 16.2-g and the 16.0-g doses (p = 0.82). Sensitivity and specificity for endoleak detection were 78.9-94.7% and 100%. Total dose-length product was lower for DECTA (788 +/- 166 mGy.cm) than for SECTA (1114 +/- 468 mGy.cm). CONCLUSION. Low-energy VMC DECTA images (40 and 50 keV) acquired with two contrast protocols at approximately 50% reduced iodine dose (16.0 and 16.2 g) provide adequate intravascular attenuation and diagnostic quality for aortoiliac evaluation.
引用
收藏
页码:467 / 474
页数:8
相关论文
共 50 条
  • [21] Measurement of Vascular Diameter in Computed Tomography Angiography With Reduced Iodine Load: Comparison of Virtual Monochromatic Imaging in Dual-Energy Computed Tomography and Conventional Polychromatic Scan In Vitro
    Sugawara, Haruto
    Suzuki, Shigeru
    Katada, Yoshiaki
    Ishikawa, Takuya
    Fukui, Rika
    Yamamoto, Yuzo
    Abe, Osamu
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 919 - 924
  • [22] Influence of virtual monochromatic spectral image at different energy levels on motion artifact correction in dual-energy spectral coronary CT angiography
    Yongjun Jia
    Bingying Zhai
    Taiping He
    Yong Yu
    Nan Yu
    Haifeng Duan
    Chuangbo Yang
    Xirong Zhang
    Japanese Journal of Radiology, 2019, 37 : 636 - 641
  • [23] Spectral Optimization of Chest CT Angiography with Reduced Iodine Load: Experience in 80 Patients Evaluated with Dual-Source, Dual-Energy CT
    Delesalle, Marie-Aurelie
    Pontana, Francois
    Duhamel, Alain
    Faivre, Jean-Baptiste
    Flohr, Thomas
    Tacelli, Nunzia
    Remy, Jacques
    Remy-Jardin, Martine
    RADIOLOGY, 2013, 267 (01) : 256 - 266
  • [24] Dual-Energy Chest CT: The Effects of Virtual Monochromatic Reconstructions On Texture Analysis Features
    Sorensen, J.
    Duran, C.
    Stingo, F.
    Wei, W.
    Rao, A.
    Zhang, L.
    Court, L.
    Erasmus, J.
    Godoy, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3214 - 3214
  • [25] HU to electron density conversion with virtual monochromatic images generated by dual-energy CT
    Gonzalez-Perez, V.
    Bartres, A.
    Arana, E.
    Crispin, V.
    De los Dolores, V.
    Campo, V.
    Oliver, L.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S862 - S862
  • [26] Dual-Energy CT-Based Monochromatic Imaging
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S9 - S15
  • [27] Virtual monochromatic imaging in dual-source and dual-energy CT for visualization of acute ischemic stroke
    Hidetake Hara
    Hiroshi Muraishi
    Hiroki Matsuzawa
    Toshiyuki Inoue
    Yasuo Nakajima
    Hitoshi Satoh
    Shinji Abe
    Journal of the Korean Physical Society, 2015, 67 : 103 - 107
  • [28] Virtual Monochromatic Imaging in Dual-source and Dual-energy CT for Visualization of Acute Ischemic Stroke
    Hara, Hidetake
    Muraishi, Hiroshi
    Matsuzawa, Hiroki
    Inoue, Toshiyuki
    Nakajima, Yasuo
    Satoh, Hitoshi
    Abe, Shinji
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 103 - 107
  • [29] Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction
    Noda, Yoshifumi
    Nakamura, Fumihiko
    Yasuda, Noriyuki
    Miyoshi, Toshiharu
    Kawai, Nobuyuki
    Kawada, Hiroshi
    Hyodo, Fuminori
    Matsuo, Masayuki
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1121):
  • [30] Iodine Beam Hardening Correction for Single KVp CT and Quantification Accuracy Relative to Dual-Energy Monochromatic CT
    Yadava, G.
    Imai, Y.
    Hsieh, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 452 - 452