Ex vivo comparison of radiographic and electronic root canal length measurements in primary molars

被引:0
|
作者
Topaloglu-Ak, A. [1 ]
Yetkiner, A. Aykut [1 ]
Baksi, B. Guniz [2 ]
Eronat, C. [1 ]
机构
[1] Ege Univ, Sch Dent, Dept Pedodont, Izmir, Turkey
[2] Ege Univ, Sch Dent, Dept Oral Radiol, Izmir, Turkey
关键词
Digital radiography; Electronic apex locator; Primary molars; Root canal lengt; ELEMENTS DIAGNOSTIC UNIT; APEX LOCATOR; PRIMARY TEETH; ZX; ACCURACY; PROPEX;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of the study was to evaluate the accuracy of root canal length measurements of primary teeth using an electronic apex locator (EAL) and digital radiography in comparison to stereomicroscopic measurement as gold standard. Materials and methods After preparation of access cavities of twenty extracted primary molars, the teeth were embedded in alginate blocks. Endodontic files were inserted in the root canals and the length was measured using ProPex II (Dentsply, Maillefer). When the reading was stable for 5s a silicone stop was used for reference. The true.lengths of the files were then measured using a micrometer. The gold standard was determined by observing the tip of the file at the apical foramen under a stereomicroscope. For radiographic measurements standard images were obtained at 30 cm source-to-object distance, and zero degrees vertical and horizontal angulations. Radiographic images of each experimental tooth were obtained with the Digora Storage Phosphor Plates (SPP) (Soredex, Orion Corporation, Helsinki, Finland) with the x-ray unit operating at 65 kVp and 10 mA for 0.16 seconds (Trophy Radiologie, Vincennes, France). The radiographic root lengths were measured with the measurement tool of the Digora for Windows software. The mean measurements of both methods were compared to the gold standard measurements using Repeated Measure ANOVA test with Bonferroni adjustments to identify the pair-wise differences (p=0.05). Results The mean measurements obtained with the EAL (14.06 +/- 1.89 mm) were significantly lower than measurements done with SPP images (14.24 +/- 1.98 mm) (p<0.05). However, when both root canal length measurement techniques were compared to stereomicroscopic measurements (gold standard), no statistically significant difference was found. Conclusions The EAL might be safer than digital radiography for the measurement of root canal length in primary teeth.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [31] Effects of CBCT acquisition protocol and additional superimposed computerized optical impressions on the accuracy of root canal length measurements: an ex vivo study
    Tchorz, Joerg Philipp
    Gierl, Valentina
    Piasecki, Lucila
    Frank, Wilhelm
    Wrbas, Karl-Thomas
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2023, 26 (02) : 117 - 124
  • [32] Octenidine in root canal and dentine disinfection ex vivo
    Tandjung, L.
    Waltimo, T.
    Hauser, I.
    Heide, P.
    Decker, E.-M.
    Weiger, R.
    INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (11) : 845 - 851
  • [33] COMPARISON OF CORONAL LEAKAGE OF DIFFERENT ROOT CANAL FILLING TECHNIQUES: AN EX VIVO STUDY
    Libonati, A.
    Di Taranto, V.
    D'Agostini, C.
    Santoro, M. M.
    Di Carlo, D.
    Ombres, D.
    Gallusi, G.
    Favalli, C.
    Marzo, G.
    Campanella, V.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2018, 32 (02): : 397 - 405
  • [34] A comparison of two root canal preparation techniques for molars.
    Pham, VK
    Bui, QD
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1324 - 1324
  • [35] An ex vivo comparison of working length determination by 3 electronic apex locators
    Pascon, Elizeu Alvaro
    Marrelli, Massimo
    Congi, Orsola
    Ciancio, Rosetta
    Miceli, Federica
    Versiani, Marco Aurelio
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (03): : E147 - E151
  • [36] Comparative evaluation of the remaining dentin volume following instrumentation with rotary, reciprocating, and hand files during root canal treatment in primary molars: An ex vivo study
    Eren, Irem
    Sezer, Berkant
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (04) : 2126 - 2134
  • [37] Accuracy of the iPex multi-frequency electronic apex locator in primary molars: an ex vivo study
    Nelson-Filho, P.
    Romualdo, P. C.
    Bonifacio, K. C.
    Leonardo, M. R.
    Silva, R. A. B.
    Silva, L. A. B.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (04) : 303 - 306
  • [38] Biocompatibility of various root canal filling materials ex vivo
    Scotti, R.
    Tiozzo, R.
    Parisi, C.
    Croce, M. A.
    Baldissara, P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2008, 41 (08) : 651 - 657
  • [39] Root Canal Morphology and Configuration of 118 Mandibular First Molars by Means of Micro-Computed Tomography: An Ex Vivo Study
    Wolf, Thomas Gerhard
    Paque, Frank
    Zeller, Maximilian
    Willershausen, Brita
    Briseno-Marroquin, Benjamin
    JOURNAL OF ENDODONTICS, 2016, 42 (04) : 610 - 614
  • [40] Characterization of an Ex Vivo Model for the Assessment of Root Canal Disinfection
    Villette, Gaelle
    Manek, Sheela
    Legner, Milos
    Fillery, Edward D.
    Torneck, Calvin D.
    Basrani, Bettina R.
    Friedman, Shimon
    JOURNAL OF ENDODONTICS, 2008, 34 (12) : 1490 - 1496