First application close measurements applying the new hybrid integrated MEMS spectrometer

被引:0
|
作者
Grueger, Heinrich [1 ]
Puegner, Tino [1 ]
Knobbe, Jens [1 ]
Schenk, Harald [1 ]
机构
[1] Fraunhofer IPMS, D-01109 Dresden, Germany
关键词
nearinfrared spectroscopy; scanning grating; MEMS; hybrid integration; integrated device; food analysis; materials analysis; environmental monitoring;
D O I
10.1117/12.2016085
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Grating spectrometers have been designed in many different configurations. Now potential high volume applications ask for extremely miniaturized and low cost systems. By the use of integrated MEMS (micro electro mechanical systems) scanning grating devices a less expensive single detector can be used in the NIR instead of the array detectors required for fixed grating systems. Meanwhile the design of a hybrid integrated MEMS scanning grating spectrometer has been drawn. The MEMS device was fabricated in the Fraunhofer IPMS own clean room facility. This chip is mounted on a small circuit board together with the detector and then stacked with spacer and mirror substrate. The spectrometer has been realized by stacking several planar substrates by sophisticated mounting technologies. The spectrometer has been designed for the 950nm-1900nm spectral range and 9nm spectral resolution with organic matter analysis in mind. First applications are considered in the food quality analysis and food processing technology. As example for the use of a spectrometer with this performance the grill process of steak was analyzed. Similar measurement would be possible on dairy products, vegetables or fruit. The idea is a mobile spectrometer for in situ and on site analysis applications in or attached to a host system providing processing, data access and input-output capabilities, disregarding this would be a laptop, tablet, smart phone or embedded platform.
引用
收藏
页数:9
相关论文
共 29 条
  • [21] New planar lightwave circuit (PLC) platform eliminating Si terraces and its application to opto-electronic hybrid integrated modules
    Yamada, T
    Hashimoto, T
    Ohyama, T
    Akahori, Y
    Kaneko, A
    Kato, K
    Kasahara, R
    Ito, M
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2001, E84B (05) : 1311 - 1318
  • [22] The hybrid integrated planar/NRD-guide technology: A new concept for low-cost application of microwave and millimeter-wave circuits
    Wu, K
    Han, L
    1996 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 1996, : 91 - 94
  • [23] Application of a hybrid ion trap/time-of-flight mass spectrometer in metabolite characterization studies: Structural identification of the metabolism profile of antofloxacin in rats rapidly using MSn information and accurate mass measurements
    Liang, Yan
    Liu, Li
    Lu, Shousi
    Xie, Lin
    Kang, An
    Xie, Tong
    Xie, Yuan
    Sheng, Longsheng
    Liu, Xiaodong
    Wang, Guang-ji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 1022 - 1025
  • [24] Implementation of a zero-field spin-echo option at the three-axis spectrometer IN3 (ILL, Grenoble) and first application for measurements of phonon line widths in superfluid 4He
    Klimko, S
    Stadler, C
    Böni, P
    Currat, R
    Demmel, F
    Fåk, B
    Gähler, R
    Mezei, F
    Toperverg, B
    PHYSICA B-CONDENSED MATTER, 2003, 335 (1-4) : 188 - 192
  • [25] Application of cooperation search-based I-PD controller with new cost function for frequency control of distributed energy integrated hybrid power system
    Chinta D.P.
    Veeranna G.
    Pothula J.
    Kumar K.K.
    Azamira S.S.N.
    Journal of Ambient Intelligence and Humanized Computing, 2024, 15 (01) : 725 - 738
  • [26] New application of reflected GPS signals L1/L2 observation techniques with an integrated GPS receiver for remote measurements and digital terrain elevation mapping
    Shen, L. C.
    Juang, J. C.
    Tseng, C. L.
    Tsai, C. L.
    Chang, C. C.
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 863 - 868
  • [27] APPLICATION OF ION STORAGE IN ELECTRON SPACE-CHARGE FIELDS TO DESIGN OF A UHV GAUGE AND MASS-SPECTROMETER ION-SOURCE .1. DESIGN OF A NEW EXTRACTOR GAUGE FOR UHV PRESSURE MEASUREMENTS
    PITTAWAY, LG
    PHILIPS RESEARCH REPORTS, 1974, 29 (03): : 261 - 282
  • [28] Development of new hybrid model of discrete wavelet decomposition and autoregressive integrated moving average (ARIMA) models in application to one month forecast the casualties cases of COVID-19
    Singh, Sarbjit
    Parmar, Kulwinder Singh
    Kumar, Jatinder
    Makkhan, Sidhu Jitendra Singh
    CHAOS SOLITONS & FRACTALS, 2020, 135
  • [29] Application of a New Hybrid Model with Seasonal Auto-Regressive Integrated Moving Average (ARIMA) and Nonlinear Auto-Regressive Neural Network (NARNN) in Forecasting Incidence Cases of HFMD in Shenzhen, China
    Yu, Lijing
    Zhou, Lingling
    Tan, Li
    Jiang, Hongbo
    Wang, Ying
    Wei, Sheng
    Nie, Shaofa
    PLOS ONE, 2014, 9 (06):