Analysis of 18 perfluorinated compounds in river waters: Comparison of high performance liquid chromatography-tandem mass spectrometry, ultra-high-performance liquid chromatography-tandem mass spectrometry and capillary liquid chromatography-mass spectrometry

被引:47
|
作者
Onghena, Matthias [1 ]
Moliner-Martinez, Y. [2 ]
Pico, Yolanda [1 ]
Campins-Falco, P. [2 ]
Barcelo, Damia [3 ,4 ]
机构
[1] Univ Valencia, Fac Pharm, Food & Environm Safety Res Grp, E-46100 Valencia, Spain
[2] Univ Valencia, Fac Chem, Dept Analyt Chem, E-46100 Valencia, Spain
[3] IDAEA CSIC, Inst Environm Assessment & Water Res, Dept Environm Chem, Barcelona 08034, Spain
[4] Univ Girona, Catalan Inst Water Res ICRA, Girona 17003, Spain
关键词
Perfluorinated compounds; HPLC-MS/MS; UHPLC-MS/MS and CLC-MS; Water samples; SCREENING ANALYSIS; COASTAL AREAS; SAMPLES; EXPOSURE; ACID; DERIVATIZATION; PERSISTENT; CHEMICALS; SEDIMENT; LIVER;
D O I
10.1016/j.chroma.2012.04.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, the performance of ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and capillary liquid chromatography-mass spectrometry (CLC-MS) has been studied for the analysis of eighteen perfluorinated compounds in water samples. UHPLC-MS/MS and CLC-MS analysis were carried out using a Zorbax C-18 column (50 mm x 2.1 mm, 1.8 mu m) and a Zorbax SB-C18 column (150 mm x 0.5 mm, 3.5 mu m), respectively, in gradient elution mode with a mobile phase of ammonium formate and methanol. Both techniques were compared with conventional LC-MS/MS in terms of speed, sensitivity, selectivity and resolution. Water samples were extracted by solid phase extraction (SPE). Mean absolute recoveries at two concentration levels, 6 and 60 ng L-1, calculated from the eighteen compounds were: 77 +/- 12(s) and 82 +/- 12(s), respectively. Relative standard deviation (RSD) was lower than 16% for each perfluorinated compound. The results obtained showed that UHPLC-MS/MS and CLC-MS allow the determination of perfluorinated compounds in water samples with satisfactory sensitivity and resolution and reduced analysis time. Therefore, both techniques were employed for the analysis of water samples to determine the target analytes at low concentration levels and with lower analysis times than using HPLC-MS/MS. Similar statistical values were obtained from both techniques at 95% confidence level. Several compounds have been detected, but perfluorooctanoic acid (PFOA) (171 ng L-1 and 148 ng L-1 by UHPLC-MS/MS and CLC-MS, respectively) showed the highest concentration. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:88 / 97
页数:10
相关论文
共 50 条
  • [21] Analysis of isothiazolinone biocides in paper for food packaging by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Lin, Q. -B.
    Wang, T. -J.
    Song, H.
    Li, B.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2010, 27 (12): : 1775 - 1781
  • [22] Ultra performance liquid chromatography-tandem mass spectrometry determination of tryptophan metabolites
    Wang, L.
    de Palma, G.
    Pearce, J. A.
    Bercik, P.
    Potter, M. A.
    CLINICAL BIOCHEMISTRY, 2012, 45 (13-14) : 1122 - 1123
  • [23] Analysis for higenamine in urine by means of ultra-high-performance liquid chromatography-tandem mass spectrometry: Interpretation of results
    Grucza, Krzysztof
    Kwiatkowska, Dorota
    Kowalczyk, Katarzyna
    Wicka, Mariola
    Szutowski, Miroslaw
    Cholbinski, Piotr
    DRUG TESTING AND ANALYSIS, 2018, 10 (06) : 1017 - 1024
  • [24] Determination of patulin in juice by ultra performance liquid chromatography-tandem mass spectrometry
    Niu Hua
    Feng Lei
    Niu Zhirui
    Zhu Na
    Zhu Hongkun
    Wang Yaqin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (09) : 957 - 961
  • [25] Survey of perfluorinated compounds in consumer products by liquid chromatography-tandem mass spectrometry
    Lee, Minjin
    Kim, Daewoo
    Park, Young-Kwon
    ENERGY & ENVIRONMENT, 2020, 31 (04) : 713 - 729
  • [26] Comparison of supercritical fluid chromatography-tandem mass spectrometry and liquid chromatography-tandem mass spectrometry for the stereoselective analysis of chlorfenvinphos and dimethylvinphos in tobacco
    Yang, Fei
    Cui, Haozhe
    Wang, Chunqiong
    Wang, Ying
    Zhu, Wenjing
    Deng, Huimin
    Liu, Shanshan
    Bian, Zhaoyang
    Lu, Junli
    Tang, Gangling
    Ji, Yuan
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (19)
  • [27] Determination of trihexyphenidyl in human plasma by ultra high performance liquid chromatography-tandem mass spectrometry
    Yang Yufei
    Xia Yunyan
    Wu Sha
    Zou Qiaogen
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (12) : 1291 - 1296
  • [28] Differentiation of regioisomeric fluoroamphetamine analogs by gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry
    Nakazono, Yukiko
    Tsujikawa, Kenji
    Kuwayama, Kenji
    Kanamori, Tatsuyuki
    Iwata, Yuko T.
    Miyamoto, Kazuna
    Kasuya, Fumiyo
    Inoue, Hiroyuki
    FORENSIC TOXICOLOGY, 2013, 31 (02) : 241 - 250
  • [29] DETERMINATION OF GINGEROLS IN GINGER BY ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Ashraf, Kamran
    Mujeeb, Mohd
    Ahmad, Altaf
    Ahmad, Sayeed
    Ahmad, Niyaz
    Amir, Mohd
    ANALYTICAL LETTERS, 2014, 47 (12) : 2120 - 2128
  • [30] Liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry determination of N-methylpyrrolidinone in riverine biofilms
    Headley, JV
    Peru, KM
    Friesen, DA
    Neu, T
    JOURNAL OF CHROMATOGRAPHY A, 2001, 917 (1-2) : 159 - 165