Analysis of 18 perfluorinated compounds in river waters: Comparison of high performance liquid chromatography-tandem mass spectrometry, ultra-high-performance liquid chromatography-tandem mass spectrometry and capillary liquid chromatography-mass spectrometry

被引:47
|
作者
Onghena, Matthias [1 ]
Moliner-Martinez, Y. [2 ]
Pico, Yolanda [1 ]
Campins-Falco, P. [2 ]
Barcelo, Damia [3 ,4 ]
机构
[1] Univ Valencia, Fac Pharm, Food & Environm Safety Res Grp, E-46100 Valencia, Spain
[2] Univ Valencia, Fac Chem, Dept Analyt Chem, E-46100 Valencia, Spain
[3] IDAEA CSIC, Inst Environm Assessment & Water Res, Dept Environm Chem, Barcelona 08034, Spain
[4] Univ Girona, Catalan Inst Water Res ICRA, Girona 17003, Spain
关键词
Perfluorinated compounds; HPLC-MS/MS; UHPLC-MS/MS and CLC-MS; Water samples; SCREENING ANALYSIS; COASTAL AREAS; SAMPLES; EXPOSURE; ACID; DERIVATIZATION; PERSISTENT; CHEMICALS; SEDIMENT; LIVER;
D O I
10.1016/j.chroma.2012.04.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, the performance of ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and capillary liquid chromatography-mass spectrometry (CLC-MS) has been studied for the analysis of eighteen perfluorinated compounds in water samples. UHPLC-MS/MS and CLC-MS analysis were carried out using a Zorbax C-18 column (50 mm x 2.1 mm, 1.8 mu m) and a Zorbax SB-C18 column (150 mm x 0.5 mm, 3.5 mu m), respectively, in gradient elution mode with a mobile phase of ammonium formate and methanol. Both techniques were compared with conventional LC-MS/MS in terms of speed, sensitivity, selectivity and resolution. Water samples were extracted by solid phase extraction (SPE). Mean absolute recoveries at two concentration levels, 6 and 60 ng L-1, calculated from the eighteen compounds were: 77 +/- 12(s) and 82 +/- 12(s), respectively. Relative standard deviation (RSD) was lower than 16% for each perfluorinated compound. The results obtained showed that UHPLC-MS/MS and CLC-MS allow the determination of perfluorinated compounds in water samples with satisfactory sensitivity and resolution and reduced analysis time. Therefore, both techniques were employed for the analysis of water samples to determine the target analytes at low concentration levels and with lower analysis times than using HPLC-MS/MS. Similar statistical values were obtained from both techniques at 95% confidence level. Several compounds have been detected, but perfluorooctanoic acid (PFOA) (171 ng L-1 and 148 ng L-1 by UHPLC-MS/MS and CLC-MS, respectively) showed the highest concentration. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:88 / 97
页数:10
相关论文
共 50 条
  • [1] Analysis of perfluorinated compounds in sludge by liquid extraction and high performance liquid chromatography-tandem mass spectrometry
    Zhang Tao
    Sun Hongwen
    Alder, Alfredo C.
    Gerecke, Andreas C.
    Muller, Claudia
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (05) : 498 - 502
  • [2] Ultra-high-performance liquid chromatography-tandem mass spectrometry for pharmacokinetics of bakuchiol in rats
    Zhang, Shuang-Qing
    Fan, Yu-Ming
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (03) : 433 - 438
  • [3] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [4] Gas chromatography-mass spectrometry and high-performance liquid chromatography-tandem mass spectrometry in quantifying fatty acids
    Wei, Gao-Ling
    Zeng, Eddy Y.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (09) : 1429 - 1436
  • [5] Residues in Drinks by High Performance Liquid Chromatography-Tandem Mass Spectrometry
    XU Dun-ming
    Zheng Xiang-Hua
    Yang Li-Zhong
    Fang En-Hua
    Chen Lu-Ping
    Lin Li-Yi
    Zhou Yu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (02) : 304 - 308
  • [6] Determination of Tranquilizers in Swine Urine by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Wang, Yingyu
    Li, Xiaowei
    Ke, Yuebin
    Wang, Chengfei
    Zhang, Yuan
    Ye, Dongyang
    Hu, Xue
    Zhou, Lan
    Xia, Xi
    MOLECULES, 2018, 23 (12):
  • [7] Determination of glucocorticoids in sewage and river waters by ultra-high performance liquid chromatography-tandem mass spectrometry
    Herrero, P.
    Borrull, F.
    Pocurull, E.
    Marce, R. M.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1224 : 19 - 26
  • [8] Determination of congo red in beef by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry
    Lin Hui
    Xu Chunxiang
    Yan Chunrong
    Zhang Zheng
    Wang Suilou
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (09) : 914 - 919
  • [9] Determination of aflatoxins in cashew by high performance liquid chromatography-tandem mass spectrometry
    Bi Ruifeng
    Fan Zhixian
    Fu Meng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (12) : 1155 - 1159
  • [10] Measurement of urinary oxypurinol by high performance liquid chromatography-tandem mass spectrometry
    Stocker, Sophie L.
    Franklin, Michael E.
    Anderson, Jacqueline M.
    Pillans, Peter I.
    Williams, Kenneth M.
    McLachlan, Andrew J.
    Day, Richard O.
    Taylor, Paul J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (25): : 2363 - 2368