Lineshape Estimation in In Vivo MR Spectroscopy without using a Reference Signal

被引:0
|
作者
Popa, E. [1 ]
Graveron-Demilly, D. [1 ]
Capobianco, E. [2 ]
de Beer, R. [3 ]
van Ormondt, D. [3 ]
机构
[1] Univ Lyon 1, INSERM, CNRS, CREATIS RMN,UMR 5220,INSA Lyon, F-69622 Villeurbanne, France
[2] CRS4 Bioinformat Lab, Cagliari, Italy
[3] Delft Univ Technol, Dept Appl Phys, Delft, Netherlands
关键词
metabolomics; MR Spectroscopy; in vivo; asymmetric lineshape; estimation error; simulations;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Metabolites can serve as biomarkers. Estimation of metabolite concentrations from an in vivo MRS signal often uses a reference signal from water for correction of the spectral line-shape. When no reference signal is available, other methods must be applied. The present work concerns semi-parametric estimation of the perturbed line-shape from simulated signals of the metabolites themselves. Errors are obtained from a Monte-Carlo calculation. The method can be useful when the water signal has not been acquired or is distorted, or when measuring on, e.g., C-13 or P-31.
引用
收藏
页码:313 / +
页数:3
相关论文
共 50 条
  • [21] Area-selective signal parameter estimation for two-dimensional MR spectroscopy data
    Sandgren, Niclas
    Stoica, Petre
    Frigo, Frederick J.
    JOURNAL OF MAGNETIC RESONANCE, 2006, 183 (01) : 50 - 59
  • [22] Reduction of lipid contamination in MR spectroscopy imaging using signal space projection
    Tsai, Shang-Yueh
    Lin, Yi-Ru
    Lin, Hsin-Yu
    Lin, Fa-Hsuan
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1486 - 1498
  • [23] Quantitative In Vivo Magnetic Resonance Spectroscopy Using Synthetic Signal Injection
    Marro, Kenneth I.
    Lee, Donghoon
    Shankland, Eric G.
    Mathis, C. Mark
    Hayes, Cecil E.
    Friedman, Seth D.
    Kushmerick, Martin J.
    PLOS ONE, 2010, 5 (12):
  • [24] In-vivo temperature measurements in brain tumors using proton MR spectroscopy
    Jayasundar, R
    Singh, VP
    NEUROLOGY INDIA, 2002, 50 (04) : 436 - 439
  • [25] Multiphase estimation without a reference mode
    Goldberg, Aaron Z.
    Gianani, Ilaria
    Barbieri, Marco
    Sciarrino, Fabio
    Steinberg, Aephraim M.
    Spagnolo, Nicolo
    PHYSICAL REVIEW A, 2020, 102 (02)
  • [26] Estimation of in vivo nonspecific binding in positron emission tomography studies without requiring a reference region
    Ogden, R. Todd
    Zanderigo, Francesca
    Parsey, Ramin V.
    NEUROIMAGE, 2015, 108 : 234 - 242
  • [27] In vivo proton MR spectroscopy of the human brain
    Barker, Peter B.
    Lin, Doris D. M.
    PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2006, 49 (02) : 99 - 128
  • [28] Future prospects for in-vivo MR spectroscopy
    Maudsley, Andrew A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1999, 9 (03) : 164 - 166
  • [29] In Vivo Proton MR Spectroscopy in Uterine Abscesses
    Takeuchi, Mayumi
    Matsuzaki, Kenji
    Harada, Masafumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (04) : 955 - 957
  • [30] Future prospects for in-vivo MR spectroscopy
    Andrew A. Maudsley
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1999, 9 (3) : 164 - 166