Lineshape Estimation in In Vivo MR Spectroscopy without using a Reference Signal

被引:0
|
作者
Popa, E. [1 ]
Graveron-Demilly, D. [1 ]
Capobianco, E. [2 ]
de Beer, R. [3 ]
van Ormondt, D. [3 ]
机构
[1] Univ Lyon 1, INSERM, CNRS, CREATIS RMN,UMR 5220,INSA Lyon, F-69622 Villeurbanne, France
[2] CRS4 Bioinformat Lab, Cagliari, Italy
[3] Delft Univ Technol, Dept Appl Phys, Delft, Netherlands
关键词
metabolomics; MR Spectroscopy; in vivo; asymmetric lineshape; estimation error; simulations;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Metabolites can serve as biomarkers. Estimation of metabolite concentrations from an in vivo MRS signal often uses a reference signal from water for correction of the spectral line-shape. When no reference signal is available, other methods must be applied. The present work concerns semi-parametric estimation of the perturbed line-shape from simulated signals of the metabolites themselves. Errors are obtained from a Monte-Carlo calculation. The method can be useful when the water signal has not been acquired or is distorted, or when measuring on, e.g., C-13 or P-31.
引用
收藏
页码:313 / +
页数:3
相关论文
共 50 条
  • [1] Quantification of in vivo 1H magnetic resonance spectroscopy signals with baseline and lineshape estimation
    Osorio-Garcia, M. I.
    Sima, D. M.
    Nielsen, F. U.
    Dresselaers, T.
    Van Leuven, F.
    Himmelreich, U.
    Van Huffel, S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (11)
  • [2] Estimation of direction of arrival based on MSWF without reference signal
    Liu, Hong-Ming
    He, Zi-Shu
    Xia, Wei
    Cheng, Ting
    Li, Jun
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2010, 38 (09): : 1979 - 1983
  • [3] In vivo detection of teriflunomide-derived fluorine signal during neuroinflammation using fluorine MR spectroscopy
    Prinz, Christian
    Starke, Ludger
    Millward, Jason M.
    Fillmer, Ariane
    Delgado, Paula Ramos
    Waiczies, Helmar
    Pohlmann, Andreas
    Rothe, Michael
    Nazare, Marc
    Paul, Friedemann
    Niendorf, Thoralf
    Waiczies, Sonia
    THERANOSTICS, 2021, 11 (06): : 2490 - 2504
  • [4] Quantification of magnetic resonance spectroscopy signals with lineshape estimation
    Osorio-Garcia, M. I.
    Sima, D. M.
    Nielsen, F. U.
    Himmelreich, U.
    Van Huffel, S.
    JOURNAL OF CHEMOMETRICS, 2011, 25 (04) : 183 - 192
  • [5] Laser Reference Sensor Alignment Estimation Using Reference Signal Observations
    Smith, Noah H.
    Bae, Sungkoo
    Webb, Charles E.
    Schutz, Bob E.
    JOURNAL OF SPACECRAFT AND ROCKETS, 2014, 51 (01) : 48 - 56
  • [6] On Model Order Estimation in Distributed Passive Radar without Reference Signal
    Elgayar, Saad
    2016 IEEE RADAR CONFERENCE (RADARCONF), 2016, : 764 - 768
  • [7] LINESHAPE OF SIGNAL IN POLARIZATION COHERENT ACTIVE ROMAN SPECTROSCOPY (CARS)
    BUNKIN, AF
    KARIMOV, MG
    KOROTEEV, NI
    VESTNIK MOSKOVSKOGO UNIVERSITETA SERIYA 3 FIZIKA ASTRONOMIYA, 1978, 19 (01): : 3 - 8
  • [8] REFERENCE LINESHAPE ADJUSTED DIFFERENCE NMR-SPECTROSCOPY .1. THEORY
    WOUTERS, JM
    PETERSSON, GA
    JOURNAL OF MAGNETIC RESONANCE, 1977, 28 (01) : 81 - 91
  • [9] Characterization of tumefactive demyelinating lesions using MR imaging and in-vivo proton MR spectroscopy
    Malhotra, H. S.
    Jain, K. K.
    Agarwal, A.
    Singh, M. K.
    Yadav, S. K.
    Husain, M.
    Krishnani, N.
    Gupta, R. K.
    MULTIPLE SCLEROSIS JOURNAL, 2009, 15 (02) : 193 - 203
  • [10] In vivo MR imaging and spectroscopy using hyperpolarized Xe-129
    Wagshul, ME
    Button, TM
    Li, HFF
    Liang, ZR
    Springer, CS
    Zhong, K
    Wishnia, A
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 183 - 191