Efficacy of percutaneous fibrin sheath stripping in restoring patency of tunneled hemodialysis catheters

被引:33
|
作者
Brady, PS [1 ]
Spence, LD [1 ]
Levitin, A [1 ]
Mickolich, CT [1 ]
Dolmatch, BL [1 ]
机构
[1] Cleveland Clin Fdn, Dept Radiol, Hosp HB6, Cleveland, OH 44195 USA
关键词
D O I
10.2214/ajr.173.4.10511171
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our objective was to determine the effectiveness of percutaneous fibrin sheath stripping as a method of restoring function to failing tunneled hemodialysis catheters. SUBJECTS AND METHODS. A total of 131 percutaneous fibrin sheath stripping procedures were performed on 100 failing tunneled hemodialysis catheters in 91 patients. Only the initial stripping procedure of the first catheter inserted in each patient was included fur analysis. Patients were excluded if an additional cause of catheter failure was noted at the time of percutaneous fibrin stripping. Failure of the hemodialysis catheter was defined as inability to sustain an average blood flow rate of 250 ml/min or more in a hemodialysis session. Patients were followed up until the time of catheter failure, catheter removal, or a second stripping. Poststripping primary patency and complication rates were determined. RESULTS. The technical success of the procedure was 95.6%. Median follow-up was 16 weeks (range, 0-128 weeks). The overall median duration of primary patency after the first stripping was 89 days (3 months). No statistically significant difference in primary patency rates was seen between patients who underwent fibrin sheath demonstration by contrast injection and those who did not (p = .71). Female patients were statistically more likely to have catheter failure after catheter stripping than were male patients (p = .02). The route of catheter insertion did not significantly influence poststripping patency rates. No complications were associated with the procedure. CONCLUSION. Percutaneous fibrin sheath stripping is a safe, effective method of restoring patency to ailing hemodialysis catheters when the failure is due to fibrin sheath formation and other causes are excluded.
引用
收藏
页码:1023 / 1027
页数:5
相关论文
共 46 条
  • [31] Effectiveness of sutureless percutaneous placement of cuffed tunneled hemodialysis catheters applying StatLock attachment devices
    Teichgraeber, Ulf Karl-Martin
    de Bucourt, Maximilian
    Gebauer, Bernhard
    Streitparth, Florian
    Hamm, Bernd
    Enzweiler, Christian
    JOURNAL OF VASCULAR ACCESS, 2011, 12 (01): : 17 - 20
  • [32] INFECTIOUS OUTCOMES OF FIBRIN SHEATH DISRUPTION IN TUNNELED DIALYSIS CATHETERS: A MARKOV MULTI-STATE MODEL OF A RETROSPECTIVE COHORT
    Waters, Mara
    Huszti, Ella
    Lok, Charmaine
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2020, 75 (04) : 650 - 651
  • [33] Percutaneous, non-surgical placement of tunneled, cuffed, external jugular hemodialysis catheters: a case report
    Yevzlin, A. S.
    Chan, M. R.
    Wolff, M. R.
    JOURNAL OF VASCULAR ACCESS, 2007, 8 (02): : 126 - 128
  • [34] Efficacy of urokinase lock to treat thrombotic dysfunction of tunneled hemodialysis catheters: A retrospective cohort study
    Van Hulle, Freya
    Bonkain, Florence
    De Clerck, Dieter
    Aerden, Dimitri
    Vanwijn, Isabelle
    Tielemans, Christian
    Wissing, Karl Martin
    JOURNAL OF VASCULAR ACCESS, 2019, 20 (01): : 60 - 69
  • [35] EFFICACY AND SAFETY OF A 4% SODIUM CITRATE LOCKING SOLUTION IN CUFFED TUNNELED HEMODIALYSIS CATHETERS COMPARED WITH HEPARIN
    Kankanala, Sucharitha
    Smith, Kathy
    Henner, David E.
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2012, 59 (04) : A45 - A45
  • [36] Safety and Efficacy of Bedside Insertion of Tunneled Hemodialysis Catheters in Critically Ill Patients with COVID-19
    Sohail, Mohammad A.
    Hanane, Tarik
    Lane, James E.
    Vachharajani, Tushar J.
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 767 - 767
  • [37] Ultrasound guided percutaneous sharp recanalization for restoring patency from peripheral chronic total occlusions of hemodialysis accesses
    Ho, Pei
    Lu, Mingxi
    Meng, Lingyan
    Hongsakul, Keerati
    JOURNAL OF VASCULAR ACCESS, 2024,
  • [38] TO STUDY THE EFFICACY OF INTRALUMINAL 70% ETHANOL VS HEPARIN LOCK PRIOR TO HEMODIALYSIS IN PREVENTION OF INFECTIONS IN NON-TUNNELED HEMODIALYSIS CATHETERS: A RANDOMISED STUDY
    Sishir, Gang
    Bhupeshkumar, Kaware
    Umapati, Hegde
    Kalpesh, Gohel
    Mohan, Rajapurkar
    NEPHROLOGY, 2014, 19 : 181 - 182
  • [39] Patency rates of dysfunctional central hemodialysis venous catheter: Comparison between catheter exchange alone and catheter exchange with fibrin sheath angioplasty
    Maldonado-Carceles, A. B.
    Garcia-Medina, J.
    Garcia-Alfonso, J. J.
    Arense-Gonzalo, J. J.
    Torres-Cantero, A. M.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2019, 100 (03) : 157 - 162
  • [40] Percutaneous Placement and Management of High-flow Catheter for Hemodialysis: The Case for DualCath, Two-tunneled, Single-lumen Silicone Catheters
    Canaud, Bernard
    Leray-Moragues, Helene
    Klouche, Kada
    Morena, Marion
    Chenine, Leila
    Miller, George
    Cristol, Jean-Paul
    Canaud, Ludovic
    INDIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2023, 10 (04) : 270 - 275