Experimental Study and Implementation of a Novel Digital Closed-Loop Control System for Coriolis Mass Flowmeter

被引:6
|
作者
Hu, Chun [1 ]
Zheng, Dezhi
Fan, Shangchun
机构
[1] Beihang Univ, Sci & Technol Inertial Lab, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Coriolis mass flowmeter; digital close-loop system; multiplying digital to analog converter; pre-tuned parameter PI controller; FLOW METER;
D O I
10.1109/JSEN.2013.2260859
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Closed-loop control system undertakes the foundational task of maintaining the permanent vibration of the measuring tube for Coriolis Mass Flowmeter (CMF). In order to overcome the disadvantages of bad anti-jamming, slow response speed and high zero drift existing in conventional analog closed-loop system, a novel digital closed-loop control system is proposed in which the Multiplying Digital to Analog Converter is introduced to track the vibration signal of CMF in real time, together with the non-linear amplitude control method to vary the amplitude gain of the excitation signal, so that the measuring tube can be adjusted to vibrate with stable amplitude promptly. The real flow calibration experimental result shows that the maximum steady state relative error and repeatability are 0.147% and 0.039%, respectively. In addition, the start-up time of measuring tube can reach to 2.75 s.
引用
收藏
页码:3032 / 3038
页数:7
相关论文
共 50 条
  • [1] Design and realization of all digital closed-loop system of Coriolis mass flowmeter
    Wang, Shuai
    Zheng, Dezhi
    Fan, Shangchun
    Tian, Jing
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2011, 37 (07): : 844 - 848
  • [2] Digital closed loop system of Coriolis mass flowmeter
    Xing, Weiwei
    Fan, Shangchun
    Zheng, Dezhi
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2006, 27 (05): : 461 - 465
  • [3] Research and Implementation of Digital Detection System for Closed-Loop FOG
    Ge, Shengmin
    Han, Junliang
    Shen, Yi
    Bian, Zhiqiang
    Wang, Hui
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 6739 - 6744
  • [4] METHOD OF CLOSED-LOOP DIGITAL CONTROL
    MONTGOMERIE, GA
    KEELING, GW
    MAY, D
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1969, 116 (08): : 1445 - +
  • [5] Digital Implementation of Retuning Fractional Controllers for an Existing Closed-loop Magnetic Levitation Control System
    Tepljakov, Aleksei
    Petlenkov, Eduard
    Belikov, Juri
    2016 39TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2016, : 630 - 633
  • [6] Application of novel method of digital to frequency conversion in Coriolis mass flowmeter
    Zheng, Dezhi
    Fan, Shangchun
    Xing, Weiwei
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2006, 32 (01): : 50 - 52
  • [7] Implementation of optimal closed-loop control strategy
    Balashevich, NV
    2002 IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER AIDED CONTROL SYSTEM DESIGN PROCEEDINGS, 2002, : 181 - 186
  • [8] A novel closed-loop system to administer propofolcomparison with manual control
    Thomas Hemmerling
    Samer Charabati
    Benjamin Dubois
    David Bracco
    Pierre Mathieu
    Canadian Journal of Anaesthesia, 2008, 55 (Suppl 1) : 4738721 - 4738722
  • [9] CLOSED-LOOP DIGITAL CONTROL OF A NUCLEAR REACTOR
    GREENE, PJ
    LENNOX, CG
    WELLS, NS
    IEEE SPECTRUM, 1965, 2 (03) : 70 - &
  • [10] Digital twin - Macro closed-loop control
    Lydon, Bill
    InTech, 2020, 67 (7-8)