Bulk and surface effects in segmented high purity germanium detectors

被引:0
|
作者
Abt, I. [1 ]
Caldwell, A. [1 ]
Doenmez, B. [1 ]
Irlbeck, S. [1 ]
Majorovits, B. [1 ]
Volynets, O. [1 ]
机构
[1] Max Planck Inst Phys & Astrophys, D-80805 Munich, Germany
关键词
Segmentation; Germanium detectors; Anisotropy; Mirror pulses; BEGe;
D O I
10.1016/j.nima.2012.11.114
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Segmented high-purity germanium detectors have been developed for a variety of experiments. The segmentation is used to augment the excellent energy resolution of such a device with spatial information to disentangle event topologies. Several performance aspects of true-coaxial segmented detectors are presented, especially the effects due to the crystallographic axes and the problem of events close to the surfaces of the detector. A test stand and Monte Carlo tools developed to study such effects are introduced. The simulation tools can also be used to design novel detectors, such as segmented point-contact detectors. A particular design is presented and discussed. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:533 / 534
页数:2
相关论文
共 50 条
  • [21] Solar proton damage in high-purity germanium detectors
    Pirard, B.
    Cabrera, J.
    d'Uston, C.
    Thocaven, J. J.
    Gasnault, O.
    Leleux, P.
    Brueckner, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (02): : 698 - 707
  • [22] EVALUATION OF HIGH-PURITY GERMANIUM BY PULSE MEASUREMENTS ON DETECTORS
    HALLER, EE
    GOULDING, FS
    HANSEN, WL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (03) : 271 - &
  • [23] TCAD simulations of internal amplification in high purity germanium detectors
    Maneuski, D.
    Gostilo, V.
    APPLIED RADIATION AND ISOTOPES, 2024, 204
  • [24] PLANAR AND COAXIAL HIGH-PURITY GERMANIUM RADIATION DETECTORS
    LLACER, J
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (02): : 259 - +
  • [25] Characteristics of GRIFFIN high-purity germanium clover detectors
    Rizwan, U.
    Garnsworthy, A. B.
    Andreoiu, C.
    Ball, G. C.
    Chester, A.
    Domingo, T.
    Dunlop, R.
    Hackman, G.
    Rand, E. T.
    Smith, J. K.
    Starosta, K.
    Svensson, C. E.
    Voss, P.
    Williams, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 820 : 126 - 131
  • [26] FURTHER STUDIES ON IMPLANTED HIGH-PURITY GERMANIUM DETECTORS
    PONPON, JP
    STUCK, R
    SIFFER, P
    KALBITZER, S
    HERZER, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (03) : 281 - +
  • [27] Characterization of high-purity germanium detectors with amorphous germanium contacts in cryogenic liquids
    Panth, R.
    Liu, J.
    Abt, I.
    Liu, X.
    Schulz, O.
    Wei, W. -Z.
    Mei, H.
    Mei, D. -M.
    Wang, G. -J.
    EUROPEAN PHYSICAL JOURNAL C, 2020, 80 (07):
  • [28] Characterization of high-purity germanium detectors with amorphous germanium contacts in cryogenic liquids
    R. Panth
    J. Liu
    I. Abt
    X. Liu
    O. Schulz
    W.-Z. Wei
    H. Mei
    D.-M. Mei
    G.-J. Wang
    The European Physical Journal C, 2020, 80
  • [29] Effects of neutron damage on the performance of large volume segmented germanium detectors
    Descovich, M
    Lee, IY
    Luke, PN
    Clark, RM
    Cromaz, M
    Deleplanque, MA
    Diamond, RM
    Fallon, P
    Macchiavelli, AO
    Rodriguez-Vieitez, E
    Stephens, FS
    Ward, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (1-2): : 199 - 209
  • [30] NEUTRON DAMAGE AND ANNEALING IN HIGH-PURITY GERMANIUM RADIATION DETECTORS
    LLACER, J
    KRANER, HW
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (03): : 467 - &