Repair of descending thoracic aortic aneurysms with Ankura Thoracic Stent Graft

被引:7
|
作者
Kratimenos, Theodoros [1 ]
Antonopoulos, Constantine N. [2 ]
Tomais, Dimitrios [1 ]
Dedeilias, Panagiotis [2 ]
Patris, Vasileios [2 ]
Samiotis, Ilias [2 ]
Kokotsakis, John [2 ]
Farsaris, Dimosthenis [1 ]
Argiriou, Michalis [2 ]
机构
[1] Evangelismos Gen Hosp Athens, Intervent Radiol Unit, Dept Radiol, Athens, Greece
[2] Evangelismos Gen Hosp Athens, Dept Cardiothorac & Vasc Surg, 45-47 Ipsilantou St, Athens 10551, Greece
关键词
Ankura; Thoracic; Aneurysm; Results; ENDOVASCULAR TREATMENT; TRIAL;
D O I
10.1016/j.jvs.2018.07.065
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The aim of the study was to present the results for patients with atherosclerotic aneurysm of the descending thoracic aorta (DTA) treated with a novel thoracic stent graft. Methods: A single-center retrospective review of prospectively collected data was performed. We extracted demographic variables as well as atherosclerotic comorbidities and operation-related and imaging-related data from patients' medical records. We estimated technical success rate, in-hospital and 30-day mortality, and mortality at the end of follow-up as well as complication and reintervention rate in our study cohort. Follow-up computed tomography angiography was performed after 1 month and 6 months and yearly thereafter. Results: A total of 30 patients (80% male; mean age, 73.7 6 6.33 years) were treated with Ankura Thoracic Stent Graft (Lifetech, Shenzhen, China) for DTA aneurysm from February 2014 until June 2017. Technical success of the thoracic endovascular aortic repair (TEVAR) was 97% (29/30 patients). A surgical conduit was required in one patient; in three patients, we intentionally covered the left subclavian artery because of insufficient proximal landing zone. No aortarelated deaths were recorded during follow-up. During the early postoperative period, two patients (7%) with long DTA coverage developed paralysis or paraparesis, which immediately resolved after lumbar drainage. No renal complications requiring dialysis were observed. One patient (3%) developed postoperative pulmonary infection, whereas access site complications were 7%. Two symptomatic patients treated outside instructions for use (7%) developed early type IA endoleak and one patient (3%) developed type IB endoleak; type II endoleak was recorded in 3% of the study cohort. During the 30-day postoperative period, two patients died of non-TEVAR-related causes, one of gastrointestinal bleeding and the other of pulmonary infection. During amedian follow-up of 31.7 (range, 38.4) months, two more patients also died of non-TEVAR-related causes, one of stroke from carotid artery disease and the other of motor vehicle trauma. In the rest of the cohort, no other adverse events were noted. Conclusions: This novel endograft showed early evidence of a safe, effective, and durable endoprosthesis for the treatment of DTA aneurysms.
引用
收藏
页码:996 / +
页数:10
相关论文
共 50 条
  • [21] The Valiant Thoracic Stent Graft for Endovascular Repair of Thoracic Aortic Aneurysms and Dissections: Looking Good So Far
    Dagenais, Francois
    JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (02) : 151 - 152
  • [22] Outcomes of Endovascular Repair of Ruptured Descending Thoracic Aortic Aneurysms
    Jonker, Frederik H. W.
    Verhagen, Hence J. M.
    Lin, Peter H.
    Heijmen, Robin H.
    Trimarchi, Santi
    Lee, W. Anthony
    Moll, Frans L.
    Athamneh, Husam
    Muhs, Bart E.
    CIRCULATION, 2010, 121 (25) : 2718 - 2723
  • [23] Thoracic Endovascular Aortic Repair for Descending Thoracic Aortic Enlargement Following Repair With the Ascyrus Medical Dissection Stent
    EL-Andari, Ryaan
    Bozso, Sabin J.
    O'Brien, Devin
    Chung, Jennifer
    Ouzounian, Maral
    Moon, Michael C.
    CANADIAN JOURNAL OF CARDIOLOGY, 2023, 39 (11) : 1698 - 1700
  • [24] Strategies to manage paraplegia risk after endovascular stent repair of descending thoracic aortic aneurysms
    Cheung, AT
    Pochettino, A
    McGarvey, ML
    Appoo, JJ
    Fairman, RM
    Carpenter, JP
    Moser, WG
    Woo, EY
    Bavaria, JE
    ANNALS OF THORACIC SURGERY, 2005, 80 (04): : 1280 - 1289
  • [25] OPTIMAL METHODS OF REPAIR OF DESCENDING THORACIC AORTIC TRANSECTIONS AND ANEURYSMS
    STAVENS, B
    HASHIM, SW
    HAMMOND, GL
    STANSEL, HC
    GATEHOUSE, J
    KOPF, GS
    GEHA, AS
    AMERICAN JOURNAL OF SURGERY, 1983, 145 (04): : 508 - 513
  • [26] Open repair of ruptured descending thoracic and thoracoabdominal aortic aneurysms
    Gaudino, Mario
    Lau, Christopher
    Munjal, Monica
    Girardi, Leonard N.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (04): : 814 - 821
  • [27] Aortic debranching for descending thoracic aortic aneurysm repair by stent grafts
    Cherukupalli, Chandra
    Dwivedi, Amit J.
    Dayal, Rajeev
    Krishnasastry, Khambapatty V.
    AMERICAN SURGEON, 2007, 73 (01) : 32 - 36
  • [28] Induction of ventricular fibrillation to facilitate endovascular stent graft repair of thoracic aortic aneurysms
    Kahn, RA
    Marin, ML
    Hollier, L
    Parsons, R
    Griepp, R
    ANESTHESIOLOGY, 1998, 88 (02) : 534 - 536
  • [29] Clinical results of endovascular stent graft repair for fifty cases of thoracic aortic aneurysms
    Kawaguchi S.
    Ishimaru S.
    Shimazaki T.
    Yokoi Y.
    Koizumi N.
    Obitsu Y.
    Ishikawa M.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 1998, 46 (10): : 971 - 975
  • [30] Dislocation of a stent-graft into the aortic arch during endovascular repair of a descending thoracic aortic aneurysm
    Augustin, N
    Bauernschmitt, R
    Hausleiter, J
    Lange, R