Repair of descending thoracic aortic aneurysms with Ankura Thoracic Stent Graft

被引:7
|
作者
Kratimenos, Theodoros [1 ]
Antonopoulos, Constantine N. [2 ]
Tomais, Dimitrios [1 ]
Dedeilias, Panagiotis [2 ]
Patris, Vasileios [2 ]
Samiotis, Ilias [2 ]
Kokotsakis, John [2 ]
Farsaris, Dimosthenis [1 ]
Argiriou, Michalis [2 ]
机构
[1] Evangelismos Gen Hosp Athens, Intervent Radiol Unit, Dept Radiol, Athens, Greece
[2] Evangelismos Gen Hosp Athens, Dept Cardiothorac & Vasc Surg, 45-47 Ipsilantou St, Athens 10551, Greece
关键词
Ankura; Thoracic; Aneurysm; Results; ENDOVASCULAR TREATMENT; TRIAL;
D O I
10.1016/j.jvs.2018.07.065
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The aim of the study was to present the results for patients with atherosclerotic aneurysm of the descending thoracic aorta (DTA) treated with a novel thoracic stent graft. Methods: A single-center retrospective review of prospectively collected data was performed. We extracted demographic variables as well as atherosclerotic comorbidities and operation-related and imaging-related data from patients' medical records. We estimated technical success rate, in-hospital and 30-day mortality, and mortality at the end of follow-up as well as complication and reintervention rate in our study cohort. Follow-up computed tomography angiography was performed after 1 month and 6 months and yearly thereafter. Results: A total of 30 patients (80% male; mean age, 73.7 6 6.33 years) were treated with Ankura Thoracic Stent Graft (Lifetech, Shenzhen, China) for DTA aneurysm from February 2014 until June 2017. Technical success of the thoracic endovascular aortic repair (TEVAR) was 97% (29/30 patients). A surgical conduit was required in one patient; in three patients, we intentionally covered the left subclavian artery because of insufficient proximal landing zone. No aortarelated deaths were recorded during follow-up. During the early postoperative period, two patients (7%) with long DTA coverage developed paralysis or paraparesis, which immediately resolved after lumbar drainage. No renal complications requiring dialysis were observed. One patient (3%) developed postoperative pulmonary infection, whereas access site complications were 7%. Two symptomatic patients treated outside instructions for use (7%) developed early type IA endoleak and one patient (3%) developed type IB endoleak; type II endoleak was recorded in 3% of the study cohort. During the 30-day postoperative period, two patients died of non-TEVAR-related causes, one of gastrointestinal bleeding and the other of pulmonary infection. During amedian follow-up of 31.7 (range, 38.4) months, two more patients also died of non-TEVAR-related causes, one of stroke from carotid artery disease and the other of motor vehicle trauma. In the rest of the cohort, no other adverse events were noted. Conclusions: This novel endograft showed early evidence of a safe, effective, and durable endoprosthesis for the treatment of DTA aneurysms.
引用
收藏
页码:996 / +
页数:10
相关论文
共 50 条
  • [1] Endovascular stent graft repair for aneurysms on the descending thoracic aorta
    Ehrlich, M
    Grabenwoeger, M
    Cartes-Zumelzu, F
    Grimm, M
    Petzl, D
    Lammer, J
    Thurnher, S
    Wolner, E
    Havel, M
    ANNALS OF THORACIC SURGERY, 1998, 66 (01): : 19 - 24
  • [2] Stent-Graft Repair of Thoracic Aortic Aneurysms
    Rousseau, H.
    Bolduc, J. P.
    Dambrin, C.
    Marcheix, B.
    Canevet, G.
    Otal, P.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 8 (01) : 61 - 72
  • [3] Descending thoracic aortic diseases: Stent-graft repair
    Fattori, R
    Napoli, G
    Lovato, L
    Grazia, C
    Piva, T
    Rocchi, G
    Angeli, E
    Di Bartolomeo, R
    Gavelli, G
    RADIOLOGY, 2003, 229 (01) : 176 - 183
  • [4] Stent Graft Repair of Paraanastomotic Aneurysms After Open Descending Thoracic and Thoracoabdominal Aortic Aneurysm Repair
    O'Connor, David J.
    Vouyouka, Ageliki
    Ellozy, Sharif H.
    Sundick, Scott A.
    LeMasters, Patrick
    Marin, Michael L.
    Faries, Peter L.
    ANNALS OF VASCULAR SURGERY, 2013, 27 (06) : 693 - 698
  • [5] Endovascular stent graft repair for aneurysms on the descending thoracic aorta - Discussion
    Miller, DC
    Ehrlich, M
    ANNALS OF THORACIC SURGERY, 1998, 66 (01): : 24 - 25
  • [6] Endovascular stent-graft repair of thoracic aortic aneurysms
    Mitchell, RS
    Dake, MD
    Semba, CP
    Fogarty, TJ
    Zarins, CK
    Liddell, RP
    Miller, DC
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05): : 1054 - 1060
  • [7] Stent graft types for endovascular repair of thoracic aortic aneurysms
    Rolph, Rachel
    Duffy, James M. N.
    Modarai, Bijan
    Clough, Rachel E.
    Taylor, Peter
    Waltham, Matthew
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (03):
  • [8] Stent graft types for endovascular repair of thoracic aortic aneurysms
    Rolph, Rachel
    Duffy, James M. N.
    Waltham, Matthew
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (09):
  • [9] Endovascular treatment of descending thoracic aortic aneurysms with the EndoFit stent-graft
    Saratzis, N.
    Saratzis, Athanasios
    Melas, N.
    Ginis, G.
    Lioupis, A.
    Lykopoulos, D.
    Lazaridis, J.
    Kiskinis, Dimitrios
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) : 177 - 181
  • [10] Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft
    N. Saratzis
    Athanasios Saratzis
    N. Melas
    G. Ginis
    A. Lioupis
    D. Lykopoulos
    J. Lazaridis
    Dimitrios Kiskinis
    CardioVascular and Interventional Radiology, 2007, 30