Cardiac implantable electronic device infections Observational data from a tertiary care center in Lebanon

被引:10
|
作者
Refaat, Marwan [1 ]
Zakka, Patrick [2 ]
Khoury, Maurice [1 ]
Chami, Hassan [2 ]
Mansour, Shareef [1 ]
Harbieh, Bernard [3 ]
Abi-Saleh, Bernard [1 ]
Bizri, Abdul Rahman [4 ]
机构
[1] Amer Univ Beirut, Dept Internal Med, Div Cardiol, Med Ctr, Beirut, Lebanon
[2] Emory Univ Hosp, Dept Internal Med, 1364 Clifton Rd NE, Atlanta, GA 30322 USA
[3] Keserwan Med Ctr, Dept Internal Med, Div Cardiol, Beirut, Lebanon
[4] Amer Univ Beirut, Dept Internal Med, Div Infect Dis, Med Ctr, Beirut, Lebanon
关键词
cardiac implantable electronic device; cardiac implantable electronic device infection; implantable cardioverter defibrillator; pacemaker; RISK-FACTORS; CARDIOVERTER-DEFIBRILLATORS; PERMANENT PACEMAKER; ENDOCARDITIS; MANAGEMENT; DIAGNOSIS; PREVENTION; EXTRACTION; TRENDS;
D O I
10.1097/MD.0000000000014906
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
With increasing rates of device implantation, there is an increased recognition of device infection. We conducted a retrospective observational study in a tertiary care center in Lebanon, with data collected from medical records of patients presenting with cardiac implantable electronic device (CIED) infection from 2000 to 2017 with the purpose of identifying etiologies, risk factors and other parameters, and comparing them to available data from the rest of the world. We identified a total of 22 CIED infections. The most common microbial etiologies, including involvement in polymicrobial infection, were coagulase-negative staphylococci (45.5%) and Staphylococcus aureus (22.7%). Rare cases of Brucella melitensis, Sphingomonas paucimobilis, and Kytococcus schroeteri device infection were seen. Heart failure was seen in 77.3% of patients, hypertension in 68.2%, and chronic kidney disease in 50%. Skin changes were the most common presenting symptoms (86.4%). Antibiotics were given to all patients and all had their devices removed, with 36.4% undergoing new device implantation. This is the first study of CIED infections in Lebanon and the Middle East. Local epidemiology and occupational exposure must be considered while contemplating the microbial etiology of infection. Close monitoring after device implantation is important in preventing device infection that carries high risk of morbidity and mortality.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Prevention, Diagnosis, and Treatment of Cardiac Implantable Electronic Device Infections
    Leung, Steven
    Danik, Stephan
    CURRENT CARDIOLOGY REPORTS, 2016, 18 (06)
  • [22] Prevalence of cardiac implantable electronic device infections in Germany in 2015
    Baldauf, Benito
    Vonthein, Reinhard
    Lau, Ernest W.
    Giaccardi, Marzia
    Assadian, Ojan
    Chevalier, Philippe
    Haddad, Christelle
    Bode, Kerstin
    Kloess, Andreas
    Cemin, Roberto
    Bonnemeier, Hendrik
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] Prevention, Diagnosis, and Treatment of Cardiac Implantable Electronic Device Infections
    Steven Leung
    Stephan Danik
    Current Cardiology Reports, 2016, 18
  • [24] Identification of causative organism in cardiac implantable electronic device infections
    Fukunaga, Masato
    Goya, Masahiko
    Nagashima, Michio
    Hiroshima, Kenichi
    Yamada, Takashi
    An, Yoshimori
    Hayashi, Kentaro
    Makihara, Yu
    Ohe, Masatsugu
    Ichihashi, Kei
    Ohtsuka, Morimasa
    Miyazaki, Hiroaki
    Ando, Kenji
    JOURNAL OF CARDIOLOGY, 2017, 70 (5-6) : 411 - 415
  • [25] Atypical pathogens associated with cardiac implantable electronic device infections
    Kohli, Utkarsh
    Hazra, Aniruddha
    Shahab, Ahmed
    Beaser, Andrew D.
    Aziz, Zaid A.
    Upadhyay, Gaurav A.
    Ozcan, Cevher
    Tung, Roderick
    Nayak, Hemal M.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (09): : 1549 - 1561
  • [26] Clinical and imaging diagnosis of cardiac implantable electronic device infections
    Hernandez-Meneses, Marta
    Perissinotti, Andres
    Vidal, Barbara
    Tolosana, Jose Maria
    Miro, Jose Maria
    CIRUGIA CARDIOVASCULAR, 2023, 30 (04): : 220 - 225
  • [27] Prevention of cardiac implantable electronic device infections: An unresolved issue
    Altunbas, Gokhan
    Vuruskan, Ertan
    Sucu, Murat
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (05): : 564 - 564
  • [28] Microbiology of cardiac implantable electronic device infections in Calgary, Canada
    King, Teagan
    Chew, Derek S.
    Leal, Jenine
    Cannon, Kristine
    Zhang, Zuying
    Rennert-May, Elissa
    ANTIMICROBIAL STEWARDSHIP & HEALTHCARE EPIDEMIOLOGY, 2024, 4 (01):
  • [29] Cardiac implantable electronic device infections: Who is at greatest risk?
    Joy, Parijat Saurav
    Kumar, Gagan
    Poole, Jeanne E.
    London, Barry
    Olshansky, Brian
    HEART RHYTHM, 2017, 14 (06) : 839 - 845
  • [30] Epidemiology of hospital-acquired infections at a tertiary care center in Lebanon
    S Kanj
    G Kamel
    L Alamuddin
    N Zahreddine
    N Sidani
    ZA Kanafani
    BMC Proceedings, 5 (Suppl 6)