Microvascular Imaging Using Compressed Sensing at 7T MRI: A Preliminary Study

被引:6
|
作者
Park, Chan-A [1 ]
Kang, Daehun [2 ,3 ]
Son, Young-Don [4 ,5 ]
Kim, Hang-Keun [4 ,5 ]
Kang, Chang-Ki [4 ,6 ]
机构
[1] Korea Basic Sci Inst, Bioimaging Res Team, Ochang, Chungbuk, South Korea
[2] Tohoku Univ, Grad Sch Informat Sci, Sendai, Miyagi 980, Japan
[3] Tohoku Univ, Kansei Fukushi Res Inst, Sendai, Miyagi 980, Japan
[4] Gachon Univ, Neurosci Res Inst, Inchon, South Korea
[5] Gachon Univ, Coll Hlth Sci, Dept Biomed Engn, Inchon, South Korea
[6] Gachon Univ, Coll Hlth Sci, Dept Radiol Sci, Inchon, South Korea
关键词
HIGH-RESOLUTION MRI;
D O I
10.1007/s00723-015-0713-0
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The aim of this study was to obtain high-resolution images with a short acquisition time using a compressed sensing (CS) technique for microvascular imaging, especially of the lenticulostriate arteries (LSAs), with 7T magnetic resonance imaging (MRI). Initially, two different radio frequency (RF) coils, birdcage and multi-channel phased array, were tested to compare images of micro-vessels acquired using the CS technique with those acquired using conventional magnetic resonance angiography (MRA) at 7T MRI. High-resolution CS MRA as well as low- and high-resolution conventional time-of-flight MRA images obtained with a multi-channel RF coil was compared to evaluate the feasibility of the CS technique for microvascular imaging. Signal intensities were then used to quantitatively estimate vessel sizes. Compared to low-resolution MRA, the CS technique improved the depiction of the LSAs and provided a substantially reduced partial volume effect of the vessels. Despite the short acquisition time of the CS technique, it clearly depicted the LSA morphology almost as well as the high-resolution MRA. The measured size difference between micro-vessels that were analyzed using the CS technique and those analyzed using high-resolution MRA was about 20 %; however, the difference between the high-resolution and the low-resolution MRA was as high as 100 %. This study evaluated the feasibility of the CS technique for microvascular imaging with 7T MRI. A CS technique that combines high-resolution imaging with a short acquisition time would be a very effective method for microvascular imaging in both research and clinical studies.
引用
收藏
页码:1189 / 1197
页数:9
相关论文
共 50 条
  • [41] Compensation for Signal Voids Caused by Turbulent Flow in Stenotic Vessels at 7T MRI: A Preliminary Study
    Kang, Chang-Ki
    Kim, Sang-Hoon
    Kim, Nambeom
    Lee, Yeong-Bae
    APPLIED MAGNETIC RESONANCE, 2016, 47 (04) : 405 - 413
  • [42] Compensation for Signal Voids Caused by Turbulent Flow in Stenotic Vessels at 7T MRI: A Preliminary Study
    Chang-Ki Kang
    Sang-Hoon Kim
    Nambeom Kim
    Yeong-Bae Lee
    Applied Magnetic Resonance, 2016, 47 : 405 - 413
  • [43] Adipose segmentation in small animals at 7T: a preliminary study
    Yang Tang
    Susan Lee
    Marvin D Nelson
    Simerly Richard
    Rex A Moats
    BMC Genomics, 11
  • [44] Emerging Role for 7T MRI and Metabolic Imaging for Pancreatic and Liver Cancer
    Rivera, Debra
    METABOLITES, 2022, 12 (05)
  • [45] Imaging of Brain Metastases of Bronchial Carcinomas with 7T MRI - Initial Results
    Moenninghoff, C.
    Maderwald, S.
    Theysohn, J. M.
    Schuett, P.
    Gauler, T.
    Kraff, O.
    Ladd, M. E.
    Ladd, S. C.
    Wanke, I.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (09): : 764 - 772
  • [46] Measurements of lenticulostriate arteries using 7T MRI: new imaging markers for subcortical vascular dementia
    Seo, Sang Won
    Kang, Chang-Ki
    Kim, Sook Hui
    Yoon, Doo Sang
    Liao, Wei
    Woerz, Stefan
    Rohr, Karl
    Kim, Young-Bo
    Na, Duk L.
    Cho, Zang-Hee
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2012, 322 (1-2) : 200 - 205
  • [47] 7T MRI in focal epilepsy with unrevealing conventional field strength imaging
    De Ciantis, Alessio
    Barba, Carmen
    Tassi, Laura
    Cosottini, Mirco
    Tosetti, Michela
    Costagli, Mauro
    Bramerio, Manuela
    Bartolini, Emanuele
    Biagi, Laura
    Cossu, Massimo
    Pelliccia, Veronica
    Symms, Mark R.
    Guerrini, Renzo
    EPILEPSIA, 2016, 57 (03) : 445 - 454
  • [48] 7T for clinical imaging of benign peripheral nerve tumors: preliminary results
    Kimberly K. Amrami
    Venkata V. Chebrolu
    Joel P. Felmlee
    Matthew A. Frick
    Garret M. Powell
    Tomas Marek
    Benjamin M. Howe
    Andrew J. Fagan
    Peter D. Kollasch
    Robert J. Spinner
    Acta Neurochirurgica, 2023, 165 : 3549 - 3558
  • [49] A new RF transmit coil for foot and ankle imaging at 7T MRI
    Santini, Tales
    Kim, Junghwan
    Wood, Sossena
    Krishnamurthy, Narayanan
    Farhat, Nadim
    Maciel, Carlos
    Raval, Shailesh
    Zhao, Tiejun
    Ibrahim, Tamer S.
    MAGNETIC RESONANCE IMAGING, 2018, 45 : 1 - 6
  • [50] 7T for clinical imaging of benign peripheral nerve tumors: preliminary results
    Amrami, Kimberly K. K.
    Chebrolu, Venkata V. V.
    Felmlee, Joel P. P.
    Frick, Matthew A. A.
    Powell, Garret M. M.
    Marek, Tomas
    Howe, Benjamin M. M.
    Fagan, Andrew J. J.
    Kollasch, Peter D. D.
    Spinner, Robert J. J.
    ACTA NEUROCHIRURGICA, 2023, 165 (11) : 3549 - 3558