Radial artery tonometry: Moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement

被引:32
|
作者
Weiss, BM
Spahn, DR
Rahmig, H
Rohling, R
Pasch, T
机构
[1] Department of Anaesthesiology, University Hospital Zürich
[2] Department of Anaesthesiology, Klinikum Ludwigsburg
关键词
arterial pressure; measurement; measurement technique; measurement techniques; tonometry; oscillometry;
D O I
10.1093/bja/76.3.405
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Radial artery tonometry provides continuous measurement of non-invasive arterial pressure (CNAP) by a sensor positioned above the radial artery. An inflatable upper arm cuff enables intermittent oscillometric calibration. CNAP was compared with invasive radial artery pressure recordings from the opposite wrist in 22 high-risk surgical patients with an inter-arm oscillometric mean arterial pressure difference less than or equal to 10 mm Hg. Oscillometric, tonometric and invasive digital pressure values, and invasive and CNAP waveforms were obtained by the same instrument (Colin BP-508). Correlation coefficients (r) of invasive vs oscillometric values (n = 481 pairs) were 0.83, 0.90 and 0.92, and mean absolute errors of oscillometry were 7.6, 4.7, and 2.6 mm Hg for systolic, diastolic and mean arterial pressures, respectively. Correlation was poor for systolic (r = 0.80), diastolic (r = 0.77) and mean (r = 0.84) invasive vs CNAP values (n = 1375). Compared with oscillometry, mean absolute errors of 15.2, 10.9 and 9.4 mm Hg for systolic, diastolic and mean CNAP, respectively, were significantly (P < 0.001) higher. Mean prediction errors of CNAP, compared with invasive values, were -5.8 (so 14.2) mm Hg for systolic, +7.2 (8.3) mm Hg for diastolic and +3.9 (8.8) mm Hg for mean arterial pressure. Individual patient accuracy of CNAP was assessed as good (individual prediction error less than or equal to 5 (8) mm Hg and individual absolute error less than or equal to 10 mm Hg) in seven patients, as acceptable (less than or equal to 10 (12) and less than or equal to 15 mm Hg) in 11 patients, and as inadequate in four of 22 patients. Individual accuracy of oscillometry was good or acceptable in all 22 patients. The trend in CNAP changes (difference between consecutive measurements) was sufficiently accurate during induction of anaesthesia, as only 47 (7.6%), 14 (2.3%) and 27 (4.4%) of 616 systolic, diastolic and mean CNAP values differed by more than 10 mm Hg of invasive pressure trends. We conclude that: intermittent oscillometry provides accurate arterial pressure monitoring; CNAP measurements offer a reliable trend indicator of pressure changes during induction of anaesthesia and may be considered an alternative to invasive pressure measurements, should arterial cannulation be difficult in an awake patient; and accuracy of absolute CNAP values is only moderate and unpredictable, thus radial artery tonometry should not replace invasive monitoring in high-risk patients during major surgical procedures.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 50 条
  • [21] Photoplethysmography: Towards a Non-Invasive Pressure Measurement Technique
    Njoum, H.
    Kyriacou, P. A.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 611 - 614
  • [22] Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy
    Siebig, Sylvia
    Rockmann, Felix
    Sabel, Karl
    Zuber-Jerger, Ina
    Dierkes, Christine
    Bruennler, Tanja
    Wrede, Christian E.
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2009, 6 (01): : 37 - 42
  • [23] A new continuous and non-invasive monitoring technique for arterial pressure (AP) in chronic hemodialysis (HD).
    Mancini, E
    Mambelli, E
    Canova, C
    Santoro, A
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 488A - 488A
  • [24] Continuous non-invasive arterial pressure measurement: Evaluation of CNAP™ device during vascular surgery
    Biais, M.
    Vidil, L.
    Roullet, S.
    Masson, F.
    Quinart, A.
    Revel, P.
    Sztark, F.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2010, 29 (7-8): : 530 - 535
  • [25] Continuous cuffless and non-invasive measurement of arterial blood pressure-concepts and future perspectives
    Pilz, Niklas
    Patzak, Andreas
    Bothe, Tomas L.
    BLOOD PRESSURE, 2022, 31 (01) : 254 - 269
  • [26] Comparison of non-invasive continuous bloodpressure measured by Nexfin® and invasive radial artery readings
    Hanot, J.
    Delande, M.
    Himpe, D.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 65 - 65
  • [27] Can Currently Available Non-invasive Continuous Blood Pressure Monitors Replace Invasive Measurement With an Arterial Catheter?
    Gore, Payton
    Liu, Hong
    Bohringer, Christian
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [28] Non-invasive measurement of arterial pressure-dependent compliance
    Liu, Changchun
    Xin, Sun
    Liu, Chengyu
    Gu, Jason J.
    Yu, Mengsun
    2007 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-3, 2007, : 590 - 593
  • [29] A new indicator for non-invasive arterial blood pressure measurement
    Regueiro-Gomez, A
    Pallas-Areny, R
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 117 - 118
  • [30] Comparison of non-invasive blood pressure versus radial arterial catheter measurement in an intensive care setting
    R Jackson
    M Jonas
    Critical Care, 9 (Suppl 1):