EARLY PREDICTION OF BLOOD LOSS AND POSTPARTUM HEMORRHAGE AFTER VAGINAL DELIVERY BY ULTRASOUND MEASUREMENT OF INTRAUTERINE CONTENT

被引:1
|
作者
Hcini, Najeh [1 ]
Mchirgui, Ali [1 ]
Pomar, Leo [2 ]
Beneteau, Samuel [3 ]
Lambert, Veronique [1 ]
Carles, Gabriel [1 ]
机构
[1] West French Guiana Hosp Ctr, Dept Obstet & Gynaecol, St Laurent Du Maroni, France
[2] Univ Hosp, Dept Femme Mere Enfant, Obstetr Serv, Maternofoetal & Obstet Res Unit, Lausanne, Switzerland
[3] West French Guiana Hosp Ctr, Univ Med Ctr, Methodol Support Unit, St Laurent Du Maroni, France
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2020年 / 46卷 / 11期
关键词
Ultrasonography; Postpartum hemorrhage; Anemia; DOUBLE-BLIND; OBSTETRICIANS;
D O I
10.1016/j.ultrasmedbio.2020.07.017
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The ability of ultrasound to predict postpartum hemorrhage remains poorly described. The aim of this study was to evaluate whether ultrasound measurement of intrauterine content can predict blood loss and postpartum hemorrhage after vaginal delivery. We used a preliminary prospective monocentric study of 201 women who delivered vaginally after 34 wk of gestation. Measurements were performed 30-45 min after normal vaginal delivery according to strict ultrasonographic criteria. Analysis of the relationship between ultrasound measurements and hemoglobin loss showed a strong linear correlation (R-2 = 0.59 and R-2 = 0.4 for isthmic and fundal measurements). The maximal value between the fundal and isthmic measurements seems to provide the best accuracy to predict loss of hemoglobin higher than 3 g/dL (area under the curve [AUC] of the receiver operating characteristic curve, 0.9; 95% confidence interval [CI], [0.76-0.97]) and post-partum hemorrhage (AUC, 0.99; 95%CI, [0.984-0.99]). In case of intrauterine content >2 cm (135/201), the risks of loss of hemoglobin higher than 3 g/dL (5/135 vs. 0/66) and post-partum hemorrhage (11/135 vs. 0/66) were increased, all the more if the intrauterine content was >4 cm (4/16 and 11/16, respectively). Considering the maximal measurement, the most optimal cut-off value for clinical practice could be 2.4 cm (sensibility 100%, specificity 57%) and 4.1 cm (sensibility 100%, specificity 97%) for loss of hemoglobin higher than 3 g/dL and post-partum hemorrhage, respectively. (E-mail: hcininajeh@gmail.com) (C) 2020 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:3145 / 3153
页数:9
相关论文
共 50 条
  • [21] Postpartum Hemorrhage after Vaginal Delivery is Associated with a Decrease in Immediate Breastfeeding Success
    Roig, Jacqueline
    Rekawek, Patricia
    Doctor, Tahera
    Naert, Mackenzie N.
    Cadet, Julie
    Monro, Johanna
    Stone, Joanne L.
    Liu, Lilly Y.
    AMERICAN JOURNAL OF PERINATOLOGY, 2025, 42 (01) : 14 - 24
  • [22] Diagnostic value of fibrinogen combined with thromboelastogram in postpartum hemorrhage after vaginal delivery
    Zhu, Xiaojuan
    Tang, Jie
    Huang, Xiaohong
    Zhou, Ying
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (03): : 1877 - 1883
  • [23] A need for further investigations on the family risk for postpartum hemorrhage after vaginal delivery
    de Moreuil, Claire
    Anouilh, Francois
    Pan-Petesch, Brigitte
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2023, 5 (09)
  • [24] Effect of Carbetocin on Postpartum Hemorrhage after Vaginal Delivery: A Meta-Analysis
    Huang, Xiaojuan
    Xue, Wanxing
    Zhou, Jin
    Zhou, Cuiyi
    Yang, Feiyan
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [25] An alternative method of Bakri balloon placement for postpartum hemorrhage after vaginal delivery
    Wang, Xiaoyin
    Yan, Mei
    Zhuang, Lin
    Xu, Zhou
    Yi, Hongying
    Zhao, Qingping
    Chen, Xiaoqin
    Chen, Lin
    Wu, Xue
    Li, Xingmei
    Yao, Yanqing
    GINEKOLOGIA POLSKA, 2024, 95 (05) : 384 - 390
  • [26] Distribution and performance of shock index to predict postpartum hemorrhage after vaginal delivery
    Madar, Hugo
    Deneux-Tharaux, Catherine
    Sentilhes, Loic
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S321 - S322
  • [27] A positive association between postpartum electrohysterography parameters and blood loss after vaginal delivery: A prospective study
    Frenken, Maria Wilhelmina Elisabeth
    van der Woude, Daisy Adriana Anne-Jan
    van Willigen, Bettine Geertrude
    Dieleman, Jeanne Petra
    Oei, Swan Gie
    van Laar, Judith Octavia Elisabeth Helena
    PLACENTA, 2025, 160 : 11 - 19
  • [28] Accuracy of blood loss estimation after vaginal delivery
    Toledo, P.
    Wong, C. A.
    Fitzgerald, P.
    McCarthy, R. J.
    ANESTHESIOLOGY, 2007, 106 (05) : B10 - B10
  • [29] The effect of uterine massage after vaginal delivery on the duration of placental delivery and amount of postpartum hemorrhage
    Kadirogullari, Pinar
    Cetin, Berna Aslan
    Goksu, Mustafa
    Arslan, Hale Cetin
    Seckin, Kerem Doga
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2024, 309 (06) : 2689 - 2695
  • [30] Laparoscopic uterine compression suture to control atonic postpartum hemorrhage after vaginal delivery
    Li, Guang-Tai
    Yang, Fang
    Wang, Zhen-Yan
    ASIAN JOURNAL OF SURGERY, 2024, 47 (03) : 1425 - 1426