摘要
Tower-line system of overhead transmission line are sensitive to wind. Therefore, dynamic effect of wind load should be taken into consideration, for instance, wind-induced vibration coefficient. There might be some errors in the calculation of the coefficient in accordance with 'Load code for the design of building structures', for its ignoring the irregular figure, scattered masses and coupling effect of tower-line system. Tower-line system is set up in virtual environment, with tower-line coupling considered, and research wind-induced vibration dynamic responses under Davenport wind speed spectrum. Random vibration theory was applied to calculate the coefficient. Whole tower was divided by hight, and calculated segment's the wind-induced vibration coefficient seprately. Compare the coefficient from Load Code and random vibration theory, the latter with tower-line coupling effect and tower figure considered, is close to the actual.
引用
收藏
页码:284 / 289
页数:6
相关论文
共 50 条
  • [21] Wind-induced response mitigation of transmission tower-line system by using magnetorheological dampers
    Hubei Key Laboratory of Roadway Bridge and Structural Engineering, Wuhan University of Technology, Wuhan 430070, China
    不详
    J Vib Shock, 2008, 3 (71-74):
  • [22] CONTROL OF WIND-INDUCED RESPONSE OF TRANSMISSION TOWER-LINE SYSTEM BY USING MAGNETORHEOLOGICAL DAMPERS
    Chen, Bo
    Zheng, Jin
    Qu, Weilian
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2009, 9 (04) : 661 - 685
  • [23] Semi-active control of wind-induced responses of transmission tower-line system by using magnetorheological dampers
    Chen, B.
    Zheng, J.
    Qu, W. L.
    STRUCTURAL CONDITION ASSESSMENT, MONITORING AND IMPROVEMENT, VOLS 1 AND 2, 2007, : 1019 - +
  • [24] Semi-active control for wind-induced responses of transmission tower-line system using friction dampers
    Chen, Bo
    Qu, Wei-Lian
    Zheng, Jin
    Gongcheng Lixue/Engineering Mechanics, 2009, 26 (01): : 221 - 226
  • [25] Dynamic Characteristics Analysis of Ice-Adhesion Transmission Tower-Line System under Effect of Wind-Induced Ice Shedding
    Yu, Yongping
    Chen, Lihui
    Wang, Juanjuan
    Liu, Guoji
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2020, 125 (02): : 647 - 670
  • [26] Wind-induced Response of UHV Guyed Single-mast Transmission Tower-line System
    Yang, WenGang
    Zhu, BoWen
    Wang, ZhangQi
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 533 - 537
  • [27] Wind-induced Progressive Collapsed Performance of Cup-type Transmission Tower-line System
    Zhang, Zhuoqun
    Lin, Youxin
    Li, Hongnan
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 2392 - +
  • [28] Dynamic analysis of transmission tower-line system subjected to wind and rain loads
    Fu, Xing
    Li, Hong-Nan
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2016, 157 : 95 - 103
  • [29] Parameter Analysis on Wind-Induced Vibration of UHV Cross-Rope Suspension Tower-Line
    Li, Xilai
    Yu, Dengke
    Li, Zhengliang
    ADVANCES IN CIVIL ENGINEERING, 2017, 2017
  • [30] An analysis of wind induced responses for Dashengguan electrical transmission tower-line system across the Yangtze River
    Liang, SG
    Ma, ZX
    Wang, LZ
    WIND ENGINEERING INTO THE 21ST CENTURY, VOLS 1-3, 1999, : 565 - 570