Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation

被引:69
|
作者
Beekman, FJ
Kamphuis, C
Viergever, MA
机构
[1] Department of Radiology and Nuclear Medicine, University Hospital Utrecht, 3584CX Utrecht
关键词
D O I
10.1109/42.511752
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction, In this paper, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter is examined, A three-dimensional (3-D) projector back-projector (proback) has been developed which models both the distance dependent detector point spread function and the object shape-dependent scatter point spread function of single photon emission computed tomography (SPECT), A table occupying only a few megabytes of memory is sufficient to represent this scatter model, The contents of this table are obtained by evaluating an analytical expression for object shape-dependent scatter, The proposed approach avoids the huge memory requirements of storing the full transition matrix needed for 3-D reconstruction including object shape-dependent scatter. In addition, the method avoids the need for lengthy Monte Carlo simulations to generate such a matrix, In order to assess the quantitative accuracy of the method, reconstructions of a water filled cylinder containing regions of different activity levels and of simulated 3-D brain projection data have been evaluated for technetium-99m. It is shown that fully 3-D reconstruction including complete detector response and object shape-dependent scatter modeling clearly outperforms simpler methods that lack a complete detector response and/or a complete scatter response model, Fully 3-D scatter correction yields the best quantitation of volumes of interest and the best contrast-to-noise curves.
引用
收藏
页码:491 / 499
页数:9
相关论文
共 50 条
  • [21] COMPENSATION FOR 3-DIMENSIONAL DETECTOR RESPONSE, ATTENUATION AND SCATTER IN SPECT GRAY-MATTER IMAGING USING AN ITERATIVE RECONSTRUCTION ALGORITHM WHICH INCORPORATES A HIGH-RESOLUTION ANATOMICAL IMAGE
    KIM, HJ
    ZEEBERG, BR
    REBA, RC
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (06) : 1225 - 1234
  • [22] Improved resolution for PET volume imaging through three-dimensional iterative reconstruction
    Liow, JS
    Strother, SC
    Rehm, K
    Rottenberg, DA
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (10) : 1623 - 1631
  • [23] Analytical compensation for spatially variant detector response in SPECT with varying focal-length fan-beam collimators
    Li, TF
    Wen, JH
    Liang, ZR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 398 - 404
  • [24] Three-dimensional bone scintigraphy using volume rendering technique and SPECT
    Ota, T
    Yamamoto, I
    Ohnishi, H
    Yuh, I
    Kigami, Y
    Suzuki, T
    Yamamura, Y
    Murata, K
    Morita, R
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (09) : 1567 - 1570
  • [25] Clinical fusion of three-dimensional images using bremsstrahlung SPECT and CT
    Parsai, EI
    Ayyangar, KM
    Dobelbower, RR
    Siegel, JA
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (02) : 319 - 324
  • [26] Three-dimensional reconstruction of heliospheric structure using iterative tomography: A review
    Jackson, B. V.
    Hick, P. P.
    Buffington, A.
    Bisi, M. M.
    Clover, J. M.
    Tokumaru, M.
    Kojima, M.
    Fujiki, K.
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2011, 73 (10) : 1214 - 1227
  • [27] Three-dimensional cardiac point cloud registration by improved iterative closest point method
    Wang B.
    Liu L.
    Hou Y.-Q.
    He X.-W.
    Hou, Yu-Qing (houyuqin@nwu.edu.cn), 1600, Chinese Academy of Sciences (28): : 474 - 484
  • [28] Quantitation of articular cartilage using magnetic resonance imaging and three-dimensional reconstruction
    Marshall, KW
    Mikulis, DJ
    Guthrie, BM
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (06) : 814 - 823
  • [29] Comparison of defect contrast and myocardial uniformity for Tl-201 SPECT using iterative reconstruction with and without attenuation, scatter and resolution compensation
    Beekman, FJ
    Kamphuis, C
    Ye, J
    Buskard, TT
    Braymer, WK
    RADIOLOGY, 1998, 209P : 327 - 327
  • [30] Compensation for Patient and Detector Scatter and Crosstalk Contamination in 111In SPECT Using Fast Monte Carlo-based Iterative Reconstruction
    Ouyang, Jinsong
    El Fakhri, Georges
    Zimmerman, Robert E.
    Moore, Stephen C.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2851 - 2853