Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation

被引:69
|
作者
Beekman, FJ
Kamphuis, C
Viergever, MA
机构
[1] Department of Radiology and Nuclear Medicine, University Hospital Utrecht, 3584CX Utrecht
关键词
D O I
10.1109/42.511752
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction, In this paper, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter is examined, A three-dimensional (3-D) projector back-projector (proback) has been developed which models both the distance dependent detector point spread function and the object shape-dependent scatter point spread function of single photon emission computed tomography (SPECT), A table occupying only a few megabytes of memory is sufficient to represent this scatter model, The contents of this table are obtained by evaluating an analytical expression for object shape-dependent scatter, The proposed approach avoids the huge memory requirements of storing the full transition matrix needed for 3-D reconstruction including object shape-dependent scatter. In addition, the method avoids the need for lengthy Monte Carlo simulations to generate such a matrix, In order to assess the quantitative accuracy of the method, reconstructions of a water filled cylinder containing regions of different activity levels and of simulated 3-D brain projection data have been evaluated for technetium-99m. It is shown that fully 3-D reconstruction including complete detector response and object shape-dependent scatter modeling clearly outperforms simpler methods that lack a complete detector response and/or a complete scatter response model, Fully 3-D scatter correction yields the best quantitation of volumes of interest and the best contrast-to-noise curves.
引用
收藏
页码:491 / 499
页数:9
相关论文
共 50 条
  • [1] Characteristics of reconstructed point response in three-dimensional spatially variant detector response compensation in SPECT
    Tsu, BMW
    Zhao, XD
    Frey, EC
    Ju, ZW
    Gullberg, GT
    THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 149 - 161
  • [2] COMPENSATION FOR ATTENUATION, SCATTER, AND DETECTOR RESPONSE IN SPECT RECONSTRUCTION VIA ITERATIVE FBP METHODS
    LIANG, ZR
    MEDICAL PHYSICS, 1993, 20 (04) : 1097 - 1106
  • [3] Evaluation of fully 3D iterative scatter compensation and post-reconstruction filtering in SPECT
    Beekman, FJ
    Viergever, MA
    THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 163 - 175
  • [4] Three-dimensional SPECT reconstruction with transmission-dependent scatter correction
    Antti Sohlberg
    Hiroshi Watabe
    Hidehiro Iida
    Annals of Nuclear Medicine, 2008, 22 : 549 - 556
  • [5] Three-dimensional SPECT reconstruction with transmission-dependent scatter correction
    Sohlberg, Antti
    Watabe, Hiroshi
    Iida, Hidehiro
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (07) : 549 - 556
  • [6] Fully 3D iterative scatter compensation in non-uniform attenuating media for SPECT.
    Beekman, FJ
    denHarder, JM
    Viergever, MA
    vanRijk, PP
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 979 - 979
  • [7] Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation
    Beekman, FJ
    de Jong, HWAM
    van Geloven, S
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) : 867 - 877
  • [8] A FAST PROJECTOR-BACKPROJECTOR PAIR MODELING THE ASYMMETRIC, SPATIALLY VARYING SCATTER RESPONSE FUNCTION FOR SCATTER COMPENSATION IN SPECT IMAGING
    FREY, EC
    JU, ZW
    TSUI, BMW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1192 - 1197
  • [9] Improved iterative pose estimation algorithm using three-dimensional feature points
    Zhang, Zhiyong
    Zhu, Dayong
    Peng, Zhenming
    Zhang, Jing
    OPTICAL ENGINEERING, 2007, 46 (12)
  • [10] A new method for modeling the spatially-variant, object-dependent scatter response function in SPECT
    Frey, EC
    Tsui, BMW
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1082 - 1086