Frequency noise measurements of 1.5 μm erbium lasers against molecular and Fabry-Perot reference lines

被引:0
|
作者
Svelto, C [1 ]
Galzerano, G [1 ]
Taccheo, S [1 ]
Laporta, P [1 ]
Bava, E [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron & Informaz, INFM, I-20133 Milan, Italy
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency stability measurements, by using a molecular absorption as a frequency discriminator, have been performed on a diode-pumped Er-Yb:glass microlaser locked to different acetylene absorption lines between 1.53 mu m and 1.54 mu m wavelengths. From the measured residual frequency fluctuations, a long-term (24-hour) rms frequency stability of 160 kHz under locking conditions for the 195 THz optical oscillator have been obtained. The Allan standard deviation of the beat frequency between two independently stabilized lasers was also measured showing a fractional frequency stability below 10(-9) for integration times between 100 mu s and 100 s. To investigate the spectral density of the frequency noise of this laser source, we are now using a very sensitive optical frequency discriminator based on a Fabry-Perot interferometer used as the reference in a Pound-Drever servo loop. The calculated sensitivity of this frequency noise detector is at the 0.3 Hz/Hz(1/2) level with the measured electronic noise floor of 300 nV/Hz(1/2). Results of the laser frequency noise under both free-running and frequency-stabilized conditions will be reported at the conference and particular emphasis will be given to the precise measurement of the flicker noise components at low and very-low Fourier frequencies.
引用
收藏
页码:2 / 5
页数:4
相关论文
共 50 条
  • [1] Frequency stability measurements of 1.5 μm erbium lasers locked to acetylene absorption lines
    Svelto, C
    Bava, E
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 537 - 539
  • [2] Frequency stability measurements of 1.5 μm erbium lasers locked to acetylene absorption lines
    Svelto, C
    Bava, E
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 189 - 190
  • [3] Miniature erbium:ytterbium fiber Fabry-Perot multiwavelength lasers
    Yamashita, Shinji
    Hsu, Kevin
    Loh, Wei H.
    IEEE Journal on Selected Topics in Quantum Electronics, 1997, 3 (04): : 1058 - 1064
  • [4] Miniature erbium:ytterbium fiber Fabry-Perot multiwavelength lasers
    Yamashita, S
    Hsu, K
    Loh, WH
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1997, 3 (04) : 1058 - 1064
  • [5] Evaluation of intensity noise in semiconductor Fabry-Perot lasers
    Sato, K
    IEICE TRANSACTIONS ON ELECTRONICS, 2004, E87C (09) : 1510 - 1516
  • [6] Reliability tests and failure analysis for quality improvement in 1.5 mu m Fabry-Perot lasers
    Montangero, P
    Azzini, GA
    Crovato, R
    Ricci, L
    Serra, L
    1996 IEEE INTERNATIONAL RELIABILITY PHYSICS PROCEEDINGS, 34TH ANNUAL, 1996, : 199 - 202
  • [7] Discretely tunable and multiwavelength erbium doped fibre lasers with Fabry-Perot etalon
    Stryjak, M.
    Budnicki, A.
    Kaczmarek, P.
    Abramski, K. M.
    2007 INTERNATIONAL STUDENTS AND YOUNG SCIENTISTS WORKSHOP PHOTONICS AND MICROSYSTEMS, PROCEEDINGS, 2007, : 74 - 77
  • [8] Discretely tunable and multiwavelength erbium doped fibre lasers with Fabry-Perot etalon
    Stryjak, M.
    Budnicki, A.
    Lewicki, R.
    Kaczmarek, P. R.
    Abramski, K. M.
    OPTO-ELECTRONICS REVIEW, 2008, 16 (02) : 179 - 184
  • [9] Calibrated Fabry-Perot etalon as 1.5-μm wavelength region absolute frequency reference based on double acetylene absorption
    Gao, HB
    Zhao, HF
    Ma, XH
    Zhou, KJ
    Optoelectronic Materials and Devices for Optical Communications, 2005, 6020 : G202 - G202
  • [10] NOISE PERFORMANCE OF A 72 m SUSPENDED FABRY-PEROT CAVITY
    Dumas, Jean-Charles
    Ju, Li
    Barriga, Pablo
    Zhao, Chunnong
    Woolley, Andrew A.
    Blair, David G.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS D, 2011, 20 (10): : 2063 - 2067