Calibrated Fabry-Perot etalon as 1.5-μm wavelength region absolute frequency reference based on double acetylene absorption

被引:0
|
作者
Gao, HB [1 ]
Zhao, HF [1 ]
Ma, XH [1 ]
Zhou, KJ [1 ]
机构
[1] Tsing Hua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
关键词
frequency stabilization; frequency standard; frequency reference; Fabry-Perot; fiber bragg grating external cavity laser diode; acetylene absorption;
D O I
10.1117/12.635374
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Absolute frequency reference in 1.5-mu m wavelength region is very useful for DWDM system. We have studied on producing artificial 1.5-mu m wavelength region absolute frequency reference by calibrating the F-P etalon. Double acetylene absorption line calibrating technique was adopted. An experiment of calibrating the Fabry-Perot etalon using double acetylene absorption lines has been demonstrated. In the experiment, Mode 1996 of the F-P etalon was locked to acetylene absorption line 1533.4621 nm. The frequency stability of the calibrated F-P etalon was about 7 X 10(-8). After calibrating, a series of artificial absolute frequency references in 1.5- mu m wavelength region was obtained. To reduce the complexity of calibrating, a novel frequency difference measurement method was introduced.
引用
收藏
页码:G202 / G202
页数:6
相关论文
共 45 条
  • [1] CALIBRATED FABRY-PEROT ETALON AS AN ABSOLUTE FREQUENCY REFERENCE FOR OFDM COMMUNICATIONS
    BOUCHER, R
    VILLENEUVE, B
    BRETON, M
    TETU, M
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1992, 4 (07) : 801 - 804
  • [2] Absolute line intensities in acetylene:: The 1.5-μm region
    El Hachtouki, R
    Vander Auwera, J
    JOURNAL OF MOLECULAR SPECTROSCOPY, 2002, 216 (02) : 355 - 362
  • [3] Multi-Wavelength Narrow-Spacing Laser Frequency Stabilization Technology Based on Fabry-Perot Etalon
    Wang, Ju
    Gao, Ye
    Yu, Jinlong
    Luo, Hao
    Su, Xuemin
    Zhang, Shiyu
    Zhang, Ruize
    Ma, Chuang
    MICROMACHINES, 2024, 15 (10)
  • [4] Frequency noise measurements of 1.5 μm erbium lasers against molecular and Fabry-Perot reference lines
    Svelto, C
    Galzerano, G
    Taccheo, S
    Laporta, P
    Bava, E
    IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 2 - 5
  • [5] Absolute distance measurement based on spectral interferometer using the effect of the FSR of a Fabry-Perot etalon
    Chen, Meiyun
    Xie, Shengli
    Zhou, Guoxu
    Wei, Dong
    Wu, Heng
    Takahashi, Satoru
    Matsumoto, Hirokazu
    Takamasu, Kiyoshi
    OPTICS AND LASERS IN ENGINEERING, 2019, 123 : 20 - 27
  • [6] Tunable Fabry-Perot etalon-based long-wavelength infrared imaging spectroradiometer
    Marinelli, WJ
    Gittins, CM
    Gelb, AH
    Green, BD
    APPLIED OPTICS, 1999, 38 (12) : 2594 - 2604
  • [8] Evaluation of Fabry-Perot cavity length by the stabilized optical frequency comb and acetylene absorption
    Smid, Radek
    Cizek, Martin
    Buchta, Zdenek
    Lazar, Josef
    Cip, Ondrej
    2011 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM/EUROPEAN FREQUENCY AND TIME FORUM PROCEEDINGS, 2011, : 345 - 348
  • [9] Tunable laser frequency lock based on a temperature-dependent Fabry-Perot etalon
    Jiang, Yuan
    Qin, Xiateng
    Su, Dianqiang
    Ji, Zhonghua
    Peng, Wenxin
    Zhao, YanTing
    APPLIED OPTICS, 2022, 61 (18) : 5381 - 5385
  • [10] Tunable Optoelectronic Oscillator with 105 Finesse Fabry-Perot Etalon as a Photonic Filter and Optical Frequency Reference
    Bagnell, Marcus
    Davila-Rodriguez, Josue
    Delfyett, Peter J.
    2012 IEEE PHOTONICS CONFERENCE (IPC), 2012, : 12 - 13