Implementation of GEC-ESTRO recommendations on 3-D based image brachytherapy

被引:6
|
作者
Haie-Meder, C. [1 ]
Dumas, I. [2 ]
Paumier, A. [1 ]
Lessard, N. [1 ]
Kanoun, S. [1 ]
Morice, P. [3 ]
Lhomme, C. [4 ]
机构
[1] Inst Gustave Roussy, Serv Curietherapie, F-94800 Villejuif, France
[2] Inst Gustave Roussy, Serv Phys, F-94800 Villejuif, France
[3] Inst Gustave Roussy, Serv Chirurg Oncol, F-94800 Villejuif, France
[4] Inst Gustave Roussy, Serv Oncol Gynecol, F-94800 Villejuif, France
来源
CANCER RADIOTHERAPIE | 2008年 / 12卷 / 6-7期
关键词
Cervix cancer; Brachytherapy; PDR; Three-dimensional dosimetry; Optimization;
D O I
10.1016/j.canrad.2008.08.277
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Even if the prognosis of patients with cervical cancer has been dramatically improved with concomitant chemoradiation, brachytherapy still plays fundamental role in the therapeutic approach of patients with Figo stage I-IV cervical carcinoma. The development of imaging with three-dimensional dosimetry has contributed to the improvement in target and organs at risk knowledge. In 2005 and 2006, GEC-ESTRO recommendations on 3-D based image brachytherapy have defined the different volumes of interest. These recommendations have been validated with intercomparison delineation studies. Data on dose to normal tissues are better known with dose volume-histograms analysis. Dose limits to the bladder are high in the range of 90 Gy to the 2 cm(3) while 2 cm(3) limits to the rectum do not differ front ICRU point. The sigmoid is currently under Study as this organ was not extensively studied before the era of imaging. Doses to the tumour (HR-CTV or IR-CTV) are not clearly stated and will likely depend on tumour extension. (C) 2008 Elsevier Masson SAS. Tous droits reserves.
引用
收藏
页码:522 / 526
页数:5
相关论文
共 50 条
  • [21] Cervical cancer treated whit HDR-brachytherapy MRI-based according to the recommendations GEC-ESTRO
    Ropero Carmona, M. F.
    Quiros Rivero, J.
    Munoz Garcia, J. L.
    Cabrera Rodriguez, J. J.
    Rios Kavadoy, Y.
    Vera Barragan, V.
    Simon Silva, P.
    Banos Perez, B.
    Corral Fernandez, C.
    Gonzalez de Duenas, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1604 - S1604
  • [22] CT IMAGE BASED DOSIMETRIC EVALUATION OF GYN GEC-ESTRO DVH PARAMETERS FOR HDR BRACHYTHERAPY IN CERVICAL CANCERS
    Jagtap, V.
    Mawlong, A.
    Mahantshetty, U.
    Jamema, S.
    Engineer, R.
    Chopra, S.
    Deshpande, D.
    Shrivastava, S. K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S258 - S258
  • [23] Equivalence of Gyn GEC-ESTRO guidelines for image guided cervical brachytherapy with EUD-based dose prescription
    William Shaw
    William ID Rae
    Markus L Alber
    [J]. Radiation Oncology, 8
  • [24] SELECTION CRITERIA FOR BRACHYTHERAPY IN PARTIAL BREAST IRRADIATION - RECOMMENDATIONS OF THE GEC-ESTRO BREAST CANCER WORKING GROUP
    Polgar, C.
    Van Limbergen, E.
    Poetter, R.
    Kovacs, G.
    Polo Rubi, J. A.
    Lyczek, J.
    Hildebrandt, G.
    Niehoff, P.
    Guinot, J. L.
    Guedea, F.
    Johansson, B.
    Ott, O. J.
    Major, T.
    Strnad, V.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S134 - S134
  • [25] Review of clinical brachytherapy uncertainties: Analysis guidelines of GEC-ESTRO and the AAPM
    Kirisits, Christian
    Rivard, Mark J.
    Baltas, Dimos
    Ballester, Facundo
    De Brabandere, Marisol
    van der Laarse, Rob
    Niatsetski, Yury
    Papagiannis, Panagiotis
    Hellebust, Taran Paulsen
    Perez-Calatayud, Jose
    Tanderup, Kari
    Venselaar, Jack L. M.
    Siebert, Frank-Andre
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 110 (01) : 199 - 212
  • [26] Equivalence of Gyn GEC-ESTRO guidelines for image guided cervical brachytherapy with EUD-based dose prescription
    Shaw, William
    Rae, William I. D.
    Alber, Markus L.
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [27] Quantification of interobserver variation in delineation of target volumes using the GEC-ESTRO recommendations for MRI based brachytherapy of the cervix.
    Kelly, C.
    Thirion, P.
    Grimley, S.
    Dimopoulos, J.
    Potter, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S272 - S272
  • [28] Magnetic Resonance Image-based Dose Volume Parameters and Clinical Outcome with High Dose Rate Brachytherapy in Cervical Cancers - A Validation of GYN GEC-ESTRO Brachytherapy Recommendations
    Mahantshetty, U.
    Swamidas, J.
    Khanna, N.
    Engineer, R.
    Merchant, N. H.
    Shrivastava, S.
    [J]. CLINICAL ONCOLOGY, 2011, 23 (05) : 376 - 377
  • [29] Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group: Considerations and pitfalls in commissioning and applicator reconstruction in 3D image-based treatment planning of cervix cancer brachytherapy
    Hellebust, Taran Paulsen
    Kirisits, Christian
    Berger, Daniel
    Perez-Calatayud, Jose
    De Brabandere, Marisol
    De Leeuw, Astrid
    Dumas, Isabelle
    Hudej, Robert
    Lowe, Gerry
    Wills, Rachel
    Tanderup, Kari
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 (02) : 153 - 160
  • [30] AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: Report of Task Group 192
    Podder, Tarun K.
    Beaulieu, Luc
    Caldwell, Barrett
    Cormack, Robert A.
    Crass, Jostin B.
    Dicker, Adam P.
    Fenster, Aaron
    Fichtinger, Gabor
    Meltsner, Michael A.
    Moerland, Marinus A.
    Nath, Ravinder
    Rivard, Mark J.
    Salcudean, Tim
    Song, Danny Y.
    Thomadsen, Bruce R.
    Yu, Yan
    [J]. MEDICAL PHYSICS, 2014, 41 (10)