Stability of miniplates and miniscrews used for orthodontic anchorage: experience with 492 temporary anchorage devices

被引:93
|
作者
Chen, Yi-Jane [1 ]
Chang, Hao-Hueng [2 ]
Lin, Hsing-Yi [3 ]
Lai, Eddie Hsian-Hua [1 ]
Hung, Hsin-Chia [4 ,5 ]
Yao, Chung-Chen Jane [1 ]
机构
[1] Natl Taiwan Univ, Dept Dent, Natl Taiwan Univ Hosp, Dept Orthodont,Sch Dent, Taipei, Taiwan
[2] Natl Taiwan Univ, Natl Taiwan Univ Hosp, Dept Dent, Dept Oral & Maxillofacial Surg,Sch Dent, Taipei, Taiwan
[3] Natl Taiwan Univ, Natl Taiwan Univ Hosp, Dept Dent, Dept Prosthodont,Sch Dent, Taipei, Taiwan
[4] Meiho Inst Technol, Grad Inst Hlth Care, Ping Dong, Taiwan
[5] Dept Food Sci & Nutr, Ping Dong, Taiwan
关键词
failure rate; orthodontic anchorage; stability; temporary anchorage device (TAD);
D O I
10.1111/j.1600-0501.2008.01571.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this retrospective study was to evaluate systematically the potential factors that influence failure rates of temporary anchorage devices (TADs) used for orthodontic anchorage. Materials and methods: Data on 492 TADs (miniplates, pre-drilling miniscrews, and self-drilling miniscrews) in 194 patients were collected. The factors related to TAD failure were evaluated using univariate analysis and multivariate forward stepwise logistic regression analysis. Results: There were no significant differences in failure rates among the TADs for the following variables: gender, type of malocclusion, facial divergency, implantation site (buccal, lingual, or crestal/midpalatal), location (anterior or posterior), method of force application (power chain or Ni-Ti coil spring), arch (upper or lower), type of soft tissue (attached gingiva or removable mucosa), and most of the cephalometric measurements that reflect dento-cranio-facial characteristics. An increased failure rate was noted for the self-drilling miniscrew type of TAD, TADs used for tooth uprighting, those inserted on bone with lower density, those associated with local inflammation of the surrounding soft tissue, those loaded within 3 weeks after insertion, and those placed in patients with greater mandibular retrusion. Failure rates of the self-drilling miniscrews installed by an oral surgeon and by an orthodontist did not differ significantly. Conclusions: Inflammation of soft tissue surrounding a TAD and early loading within 3 weeks after insertion were the most significant factors predicting TAD failure. Both orthodontists and oral surgeons who install orthodontic TADs must undergo sufficient training to achieve clinical excellence.
引用
收藏
页码:1188 / 1196
页数:9
相关论文
共 50 条
  • [31] Oral microbiome contributes to the failure of orthodontic temporary anchorage devices (TADs)
    Ningrui Zhao
    Qian Zhang
    Yanning Guo
    Shengjie Cui
    Yajing Tian
    Yidan Zhang
    Yanheng Zhou
    Xuedong Wang
    BMC Oral Health, 23
  • [32] Temporary Anchorage Devices: An Insight
    Rao, Aravindaksha
    Deepak, C.
    Kritika, A.
    Deenadayalan, P.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (12): : 206 - 211
  • [33] Temporary anchorage devices -: Response
    Akyalcin, Sercan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (05) : 575 - 575
  • [34] Esthetic orthodontic treatment with a double J retractor and temporary anchorage devices
    Park, Jae Hyun
    Tai, Kiyoshi
    Takagi, Masato
    Miyajima, Kuniaki
    Kojima, Yukio
    Joo, Bo-Hoon
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 141 (06) : 796 - 805
  • [35] Midpalatal miniscrews for orthodontic anchorage: Factors affecting clinical success
    Kim, Young Ho
    Yang, Seung-Min
    Kim, Seonwoo
    Lee, Joo Yong
    Kim, Kyu Eok
    Gianelly, Anthony A.
    Kyung, Seung-Hyun
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (01) : 66 - 72
  • [36] Tissue reaction surrounding miniscrews for orthodontic anchorage: An animal experiment
    Chen, Stephanie Shih-Hsuan
    Chang, Hao-Hueng
    Chen, Yuan-Hou
    Wang, Yi-Ping
    Chen, Yunn-Jy
    Chen, Yi-Jane
    Lai, Hsiang-Hua Eddie
    Yao, Chung-Chen Jane
    JOURNAL OF DENTAL SCIENCES, 2012, 7 (01) : 57 - 64
  • [37] Revisiting the stability of mini-implants used for orthodontic anchorage
    Yao, Chung-Chen Jane
    Chang, Hao-Hueng
    Chang, Jenny Zwei-Chieng
    Lai, Hsiang-Hua
    Lu, Shao-Chun
    Chen, Yi-Jane
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2015, 114 (11) : 1122 - 1128
  • [38] Assessment of stiffness and load deflection of orthodontic miniscrews used for palatal anchorage: An in vitro biomechanical study
    Colonna, Anna
    Drudi, Margherita
    Spedicato, Giorgio Alfredo
    Mollica, Francesco
    Mazzanti, Valentina
    Paoletto, Emanuele
    Maino, Giuliano
    Siciliani, Giuseppe
    Lombardo, Luca
    INTERNATIONAL ORTHODONTICS, 2020, 18 (04) : 809 - 819
  • [39] Dynamics of alveolar bone healing after the removal of orthodontic temporary anchorage devices
    Kim, Sung-Jin
    Ha, Young Don
    Kim, Eunji
    Jang, Woowon
    Hwang, Soonshin
    Tung Nguyen
    Ko, Ching-Chang
    Choi, Yoon Jeong
    Kim, Kyung-Ho
    Chung, Chooryung J.
    JOURNAL OF PERIODONTAL RESEARCH, 2019, 54 (04) : 388 - 395
  • [40] Soft bone primary stability of 3 different miniscrews for orthodontic anchorage: A resonance frequency investigation
    Veltri, Mario
    Balleri, Beatrice
    Goracci, Cecilia
    Giorgetti, Roberto
    Balleri, Piero
    Ferrari, Marco
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (05) : 642 - 648