Qualitative determination of inorganic anions in incendiary device residues by capillary electrophoresis

被引:14
|
作者
Martin-Alberca, Carlos [1 ,2 ]
Saiz, Jorge [1 ,2 ]
Luis Ferrando, Jose [1 ,3 ]
Garcia-Ruiz, Carmen [1 ,2 ]
机构
[1] Univ Alcala Ctra, Univ Inst Res Police Sci IUICP, Alcala De Henares 28871, Madrid, Spain
[2] Univ Alcala Ctra, Dept Analyt Chem, Alcala De Henares 28871, Madrid, Spain
[3] Criminalist Serv Guardia Civil, Madrid 28003, Spain
关键词
CONTACTLESS CONDUCTIVITY DETECTION; IMPROVISED EXPLOSIVE DEVICES; ION CHROMATOGRAPHY; POSTBLAST RESIDUES; THERMAL-DECOMPOSITION; POTASSIUM CHLORATE; IDENTIFICATION; INSTRUMENTATION; PERCHLORATE; SEPARATION;
D O I
10.1039/c2ay25628b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of the inorganic anions present in residues from improvised incendiary devices (IIDs) is of interest to the police to obtain information about the type of device employed, and to determine its composition. The Chemical Ignition Molotov Cocktail (CIMC) is an IID of increasing use. In this paper, an analytical procedure for sample treatment and qualitative analysis by CE is applied to determine the anionic composition of CIMC residues. First, a comparison of two CE methods for the separation of three target anions present in CIMCs (sulfate, chlorate, and chloride) was made by considering chromate- and pyromellitic acid (PMA)-based buffers. After the analysis of CIMC samples prepared in the laboratory under controlled conditions (Lab-CIMC samples) perchlorate was found to be a novel target anion useful for the identification of CIMCs. This result allowed recommendation of the PMA-based buffer to police forces for the separation of target anions in CIMC samples, even if chloride and sulfate may be partially overlapped under these conditions. Finally, the analytical procedure was applied to the analysis of real CIMC residues and soil samples. Chlorate and perchlorate are the target anions making possible the identification of CIMC since the other studied anions may have originated from other sources.
引用
收藏
页码:2680 / 2686
页数:7
相关论文
共 50 条
  • [21] Analysis of inorganic anions by capillary zone electrophoresis
    Park, SW
    Jin, KH
    You, JH
    Kim, TJ
    Paeng, KJ
    Kong, KH
    ANALYTICAL SCIENCES, 1997, 13 : 243 - 246
  • [22] Quantitative capillary zone electrophoresis of inorganic anions
    Paull, B
    King, M
    ELECTROPHORESIS, 2003, 24 (12-13) : 1892 - 1934
  • [23] Capillary zone electrophoresis method for the determination of inorganic anions and formic acid in honey
    Suarez-Luque, Silvia
    Mato, Ines
    Huidobro, Jose F.
    Simal-Lozano, Jesus
    Sancho, M. Teresa
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (25) : 9292 - 9296
  • [24] Determination of inorganic cations and anions in single plant cells by capillary zone electrophoresis
    Bazzanella, A
    Lochmann, H
    Tomos, AD
    Bächmann, K
    JOURNAL OF CHROMATOGRAPHY A, 1998, 809 (1-2) : 231 - 239
  • [25] On-column preconcentration and determination of inorganic anions in cigarette samples with capillary electrophoresis
    Zhang, ZX
    He, YZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (11) : 1531 - 1534
  • [26] Simultaneous determination of inorganic anions and cations by capillary electrophoresis with indirect UV detection
    Haumann, I
    Boden, J
    Mainka, A
    Jegle, U
    JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) : 269 - 277
  • [27] Simultaneous determination of inorganic anions, organic acids and metal cations by capillary electrophoresis
    Tomoyoshi, S
    Ross, GA
    JOURNAL OF CHROMATOGRAPHY A, 1999, 834 (1-2) : 65 - 71
  • [28] Application of capillary electrophoresis for the determination of inorganic ions in trace explosives and explosive residues
    Kishi, T
    Nakamura, J
    Arai, H
    ELECTROPHORESIS, 1998, 19 (01) : 3 - 5
  • [29] Determination of inorganic anions by capillary electrochromatography
    Breadmore, MC
    Hilder, EF
    Macka, M
    Haddad, PR
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (6-7) : 355 - 364
  • [30] OPTIMIZATION OF DETECTION SENSITIVITY IN THE CAPILLARY ELECTROPHORESIS OF INORGANIC ANIONS
    JANDIK, P
    JONES, WR
    JOURNAL OF CHROMATOGRAPHY, 1991, 546 (1-2): : 431 - 443