Active compensation of unbalanced supply voltages for two-stage direct power converters using the clamp capacitor

被引:1
|
作者
Klumpner, C [1 ]
Wijekoon, T [1 ]
Wheeler, P [1 ]
机构
[1] Univ Nottingham, Sch Elect & Elect Engn, Nottingham NG7 2RD, England
关键词
D O I
10.1109/PESC.2005.1581965
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Unbalanced supply voltages can be fully compensated in boost type power converters with active front end if sufficient energy storage is provided by the DC-link capacitor. In converters that have no energy storage, for example in a matrix converter, the maximum voltage transfer ratio will be reduced if one or more input lines is at a reduced voltage. Control techniques to compensate the effect of unbalanced voltage supply for matrix converters allow for a limited output voltage and power capabilities, which depends on the level of unbalance. This paper proposes the utilization of the clamp capacitor, which is normally needed only to protect a Direct Power Converter (DPC), to extend the operating range of a Two-Stage DPC during unbalanced supply conditions preserving its theoretic maximum voltage transfer ratio capability. This solution is validated through simulations.
引用
收藏
页码:2376 / 2382
页数:7
相关论文
共 50 条
  • [21] Modeling of two-stage continuous co-phase traction power supply system with different compensation schemes
    Wang, Hui
    Xie, Shaofeng
    Li, Weilan
    Li, Qunzhan
    Ci, Kaixuan
    Zhong, Fan
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 245
  • [22] On the power efficiency of cascode compensation over Miller compensation in two-stage operational amplifiers
    Aminzadeh, Hamed
    Lotfi, Reza
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2008, 17 (01) : 1 - 13
  • [23] Current Control for Third-Harmonic Injection Two-stage Matrix Converter Under Unbalanced Input Voltages
    Tang, Zhongting
    Han, Hua
    Su, Mei
    Li, Xin
    Guo, Bin
    Wang, Hui
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017,
  • [24] TWO-STAGE ADAPTIVE COMPENSATION OF ACTIVE NOISE INTERFERENCE WITH SIGNALS ORTHOGONALIZATION OF A PART OF COMPENSATION CHANNELS
    Zhuk, S. Ya
    Semibalamut, K. M.
    VISNYK NTUU KPI SERIIA-RADIOTEKHNIKA RADIOAPARATOBUDUVANNIA, 2016, (64): : 61 - 74
  • [25] Invariant Modulation Strategy for Two-stage Direct Power Converter
    Bekbudov, Radiy
    2008 13TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-5, 2008, : 337 - 344
  • [26] Active-RC filters using two-stage OTAs with and without feed-forward compensation
    Kamat, D. V.
    Mohan, P. V. Ananda
    Prabhu, K. Gopalakrishna
    IET CIRCUITS DEVICES & SYSTEMS, 2011, 5 (06) : 527 - 535
  • [27] Maximum Efficiency Point Tracking for Two-Stage Server Power Supply
    Lai, Yen-Shin
    Yu, Min-Hsiang
    2019 IEEE 4TH INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE (IFEEC), 2019,
  • [28] Table-Based Direct Power Control for Three-Phase AC/DC Converters Under Unbalanced Grid Voltages
    Zhang, Yongchang
    Qu, Changqi
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (12) : 7090 - 7099
  • [29] An Optimized Active Power Control Method of Two-Stage Grid-Connected Photovoltaic Inverter under Unbalanced Grid Faults
    Xiong, Hao
    Du, Xiong
    Sun, Pengju
    Ji, Yongliang
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 817 - 822
  • [30] Two-stage optimal configuration of DESS for an unbalanced distribution network considering four-quadrant operation of converters
    Li Y.
    Cai H.
    Wang D.
    Bai B.
    Wu X.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (14): : 106 - 117