A comparison on radiation tolerance of ⟨100⟩ and ⟨111⟩ silicon substrates of microstrip detectors

被引:6
|
作者
Calefato, G
Creanza, D
de Palma, M
Fiore, L
My, S
Radicci, V
Selvaggi, G
Tempesta, P
Angarano, MM
Bilei, GM
Biasini, M
Giorgi, M
Militaru, O
Servoli, L
机构
[1] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
[2] Univ Bari, Dipartimento Interateneo Fis, I-70126 Bari, Italy
[3] Ist Nazl Fis Nucl, Sez Perugia, I-06100 Perugia, Italy
[4] Dipartimento Interateneo Fis, Perugia, Italy
关键词
silicon detector; substrate resistivity; crystal orientation; neutron irradiation;
D O I
10.1016/S0168-9002(01)01667-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison between silicon microstrip detectors with the same geometry built on < 1 0 0 > and < 1 1 1 > substrates have been carried out. Three sets of structures- < 1 0 0 > low resistivity, < 1 1 1 > low resistivity and < 1 1 1 > high resistivity-have been electrically characterized. Leakage current, depletion voltage, interstrip capacitance and resistance have been measured before and after neutron irradiation. The samples have been irradiated at five different fluences, up to similar or equal to 1.5 x 10(14) n/cm(2). The measurements show that the leakage current does not depend, at a given fluence, on crystal orientation and on silicon resistivity. At high irradiation fluences the interstrip resistance decreases for all structures to few tens MOmega. The low resistivity substrates, after type inversion, have a lower depletion voltage than the high resistivity ones. The interstrip capacitance is much less sensitive to radiation effects in < 1 0 0 > than in < 1 1 1 > structures. We conclude that < 1 0 0 > low resistivity sensors show, after irradiation, better performances with respect to standard < 1 1 1 > high resistivity devices. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:744 / 750
页数:7
相关论文
共 50 条
  • [21] High statistics study of radiation damage on silicon microstrip detectors
    Dutta, S
    Borrello, L
    Dell'Orso, R
    Giassi, A
    Messineo, A
    Segneri, G
    Starodumov, A
    Teodorescu, L
    Tonelli, G
    Verdini, PG
    Xie, Z
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2303 - 2306
  • [22] Radiation hardness of the HERA-B silicon microstrip detectors
    Pugatch, V
    Abt, I
    Bauer, C
    Bräuer, M
    Dressel, M
    Glebe, T
    Hofmann, W
    Knöpfle, KT
    Masciocchi, S
    Moshous, B
    Perschke, T
    Riechmann, K
    Schaller, S
    Schmelling, M
    Schwingenheuer, B
    Sexauer, E
    Trunk, U
    Wanke, R
    Wagner, W
    Zurheide, F
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1999, 112 (11): : 1383 - 1389
  • [23] RADIATION EFFECTS ON AC-COUPLED MICROSTRIP SILICON DETECTORS
    BACCHETTA, N
    BISELLO, D
    BOLLA, G
    CANALI, C
    FUOCHI, PG
    PACCAGNELLA, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2): : 381 - 385
  • [24] Investigation of design parameters for radiation hard silicon microstrip detectors
    Braibant, S
    Demaria, N
    Feld, L
    Frey, A
    Fürtjes, A
    Glessing, W
    Hammarström, R
    Honma, A
    Mannelli, M
    Mariotti, C
    Mättig, P
    Migliore, E
    Piperov, S
    Runolfsson, O
    Schmitt, B
    Söldner-Rembold, A
    Surrow, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (03): : 343 - 361
  • [25] Comparison of CDMS [100] and [111] Oriented Germanium Detectors
    Leman, S. W.
    Hertel, S. A.
    Kim, P.
    Cabrera, B.
    Do Couto E Silva, E.
    Figueroa-Feliciano, E.
    McCarthy, K. A.
    Resch, R.
    Sadoulet, B.
    Sundqvist, K. M.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (5-6) : 1106 - 1111
  • [26] Comparison of CDMS [100] and [111] Oriented Germanium Detectors
    S. W. Leman
    S. A. Hertel
    P. Kim
    B. Cabrera
    E. Do Couto E Silva
    E. Figueroa-Feliciano
    K. A. McCarthy
    R. Resch
    B. Sadoulet
    K. M. Sundqvist
    Journal of Low Temperature Physics, 2012, 167 : 1106 - 1111
  • [27] Superior radiation tolerance of thin epitaxial silicon detectors
    Kramberger, G
    Contarato, D
    Fretwurst, E
    Hönniger, F
    Lindström, G
    Pintilie, I
    Röder, R
    Schramm, A
    Stahl, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 515 (03): : 665 - 670
  • [28] Studies of radiation damage in silicon microstrip detectors for the D empty set silicon tracker
    Gomez, R
    Bischoff, A
    Boswell, C
    Dionson, J
    Ellison, J
    Heinson, AP
    JoffeMinor, T
    Gutierrez, P
    Guglielmo, G
    Gu, W
    Cooper, W
    Johnson, M
    Lipton, R
    Mishra, S
    Rapidis, PA
    Spiegel, L
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 867 - 871
  • [30] Radiation-induced surface leakage currents in silicon microstrip detectors
    Foland, AD
    Alexander, JP
    Hopman, PI
    Kim, PC
    Ward, CW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1746 - 1750