Role of free radicals in aseptic loosening of hip arthroplasty

被引:56
|
作者
Kinov, P
Leithner, A
Radl, R
Bodo, K
Khoschsorur, GA
Schauenstein, K
Windhager, R
机构
[1] Med Univ Graz, Dept Orthopaed Surg, A-8036 Graz, Austria
[2] Med Univ Sofia, Dept Orthopaed & Traumatol, Sofia 1527, Bulgaria
[3] Med Univ Graz, Inst Pathol, A-8036 Graz, Austria
[4] Med Univ Graz, Inst Clin Med, A-8036 Graz, Austria
[5] Med Univ Graz, Chem Lab Diagnost, A-8036 Graz, Austria
[6] Med Univ Graz, Inst Pathophysiol, A-8010 Graz, Austria
关键词
free radicals; aseptic loosening; oxidative stress; hip arthroplasty; periprosthetic fibrosis;
D O I
10.1002/jor.20013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fibrous pseudocapsule around hip implants is an invariable finding at revision operations and is believed to release inflammatory mediators that stimulate bone resorption. Reactive oxygen species have been proposed to be causative factors in various disorders with tissue fibrosis. We were interested in investigating whether aseptic loosening is connected with high oxidative stress, and in showing the underlying mechanism of periprosthetic fibrosis and its role in loosening. Levels of oxidative stress markers reduced (GSH) and oxidized (GSSG) gluthatione and malondialdehyde (MDA) were assayed in 28 loose hips and in 12 stable hips revised for high rate of wear and osteolysis. Collagen in the periprosthetic tissues was measured as hydroxyproline content. Osteolysis and polyethylene wear were graded. Increased oxidative stress measured by low GSH/GSSG ratio as well as by increased MDA level was established in patients compared to controls. Oxidative stress markers intercorrelated significantly. MDA and both GSH and GSSG levels correlated significantly with hydroxyproline level. Levels of GSSG and MDA were higher in hips with greater polyethylene wear. The results suggest that high oxidative stress may play a role in formation of a fibrous membrane observed at revision of loose hips. The fibrous pseudocapsule is probably related to high intraarticular pressure and expansion of the effective joint space. This study may elicit some aspects of the pathogenesis of aseptic hip loosening and aid in future investigations aiming at prevention of this complication. (c) 2005 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 50 条
  • [31] Granulocyte-macrophage colony stimulating factor in the aseptic loosening of total hip arthroplasty
    Xu, JW
    Konttinen, YT
    Waris, V
    GomezBarrena, E
    Sorsa, T
    Santavirta, S
    JOURNAL OF ORTHOPAEDIC RHEUMATOLOGY, 1996, 9 (03): : 128 - 134
  • [32] Bisphosphonates' use and risk of aseptic loosening following total hip arthroplasty: a systematic review
    Pegios, Vasileios F.
    Kenanidis, Eustathios
    Tsotsolis, Stavros
    Potoupnis, Michael
    Tsiridis, Eleftherios
    EFORT OPEN REVIEWS, 2023, 8 (11) : 798 - 808
  • [33] Local and Systemic Activation of the Mononuclear Phagocyte System in Aseptic Loosening of Total Hip Arthroplasty
    Flecher, Xavier
    Rolland, Christelle
    Rixrath, Emmanuel
    Argenson, Jean-Noel
    Robert, Philippe
    Bongrand, Pierre
    Wendling, Sylvie
    Vitte, Joana
    JOURNAL OF CLINICAL IMMUNOLOGY, 2009, 29 (05) : 681 - 690
  • [34] Diabetes mellitus is a potential risk factor for aseptic loosening around hip and knee arthroplasty
    Deng, Yi
    Smith, Paul N.
    Li, Rachel W.
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [35] Local and Systemic Activation of the Mononuclear Phagocyte System in Aseptic Loosening of Total Hip Arthroplasty
    Xavier Flecher
    Christelle Rolland
    Emmanuel Rixrath
    Jean-Noel Argenson
    Philippe Robert
    Pierre Bongrand
    Sylvie Wendling
    Joana Vitte
    Journal of Clinical Immunology, 2009, 29 : 681 - 690
  • [36] The relationship between cup design and the radiological signs of aseptic loosening in total hip arthroplasty
    Müller, U
    Gautier, E
    Roeder, C
    Busato, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (01): : 31 - 36
  • [37] ASEPTIC LOOSENING IN TOTAL HIP IMPLANTS - THE ROLE OF POLYETHYLENE WEAR DEBRIS
    BOYNTON, E
    WADDELL, JP
    MORTON, J
    GARDINER, GW
    CANADIAN JOURNAL OF SURGERY, 1991, 34 (06) : 599 - 605
  • [38] Revision resurfacing knee arthroplasty for aseptic loosening
    A. Karbowski
    A. Eckardt
    M. Schwitalle
    J. Heine
    Archives of Orthopaedic and Trauma Surgery, 1998, 117 : 256 - 258
  • [39] "Unexpected" Infections in Revision Arthroplasty for Aseptic Loosening
    Nikolaev, Nikolay S.
    Pchelova, Nadezhda N.
    Preobrazhenskaya, Elena, V
    Nazarova, Valentina V.
    Dobrovol'skaya, Natal'ya Yu
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2021, 27 (03): : 56 - 70
  • [40] THE PROBLEM IN TOTAL JOINT ARTHROPLASTY - ASEPTIC LOOSENING
    GOLDRING, SR
    CLARK, CR
    WRIGHT, TM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (06): : 799 - 801