Innovative telemonitoring system for cardiology: from science to routine operation

被引:31
|
作者
Kastner, P. [1 ]
Morak, J. [1 ]
Modre, R. [1 ]
Kollmann, A. [1 ]
Ebner, C. [2 ]
Fruhwald, F. M. [3 ]
Schreier, G. [1 ]
机构
[1] AIT Austrian Inst Technol GmbH, Safety & Secur Dept, A-8020 Graz, Austria
[2] Allgemeines Offentl Krankenhaus Elisabethine Linz, Linz, Austria
[3] Med Univ Graz, Dept Cardiol, Graz, Austria
来源
APPLIED CLINICAL INFORMATICS | 2010年 / 1卷 / 02期
关键词
Heart failure; telemedicine; mobile phone; eHealth; near field communication technology; HEART-FAILURE; PROGNOSIS;
D O I
10.4338/ACI-2009-12-RA-0021
中图分类号
R-058 [];
学科分类号
摘要
Objective: Results of the Austrian MOBITEL (MOBIle phone based TELemonitoring for heart failure patients) trial indicate that home-based telemonitoring improves outcome of chronic heart failure (CHF) patients and reduces both frequency and duration of hospitalizations. Based on lessons learned, we assessed the weak points to clear the way for routine operations. Methods: We analyzed the system with respect to recommendations of the ESC Guidelines and experiences gained throughout the trial to identify potential improvements. The following components have been identified: a patient terminal with highest usability, integrated way to document drug-intake and well-being, and automated event detection for worsening of CHF. As a consequence the system was extended by Near Field Communication (NFC) technology and by an event management tool. Results: Usability evaluation with 30 adults (14f, median 51y. IQR[45-65]) showed that 21 (8f) were able to immediately operate the system after reading a step-by-step manual. Eight (6f) needed one time demonstration and one man (80y) failed to operate the blood pressure meter. Routine operation of the revised system started in March 2009. Within 9 months, 15 patients (4f, median 74y. IQR[71-83], all NYHA-III) transmitted 17,149 items. 43 events were detected because of body weight gain of more then 2kg within 2 days. 49 therapy adjustments were documented. Three patients stopped using the system, two (1f) because of non-compliance and one (m, 82y) because of death. Overall, the rate of adherence to daily data transfer was 78%. Conclusion: First results confirm the applicability of the revised telemonitoring system in routine operation.
引用
收藏
页码:165 / 176
页数:12
相关论文
共 50 条
  • [31] Telemonitoring in-home complex chronic patients from primary care in routine clinical practice: Impact on healthcare resources use
    Martin-Lesendea, Inaki
    Orruno, Estibalitz
    Mateos, Maider
    Recalde, Elizabete
    Asua, Jose
    Reviriego, Eva
    Carlos Bayon, Juan
    EUROPEAN JOURNAL OF GENERAL PRACTICE, 2017, 23 (01) : 136 - 143
  • [32] Function Reorientation of Government in the Process of Science & Technology System Operation in China
    Neng, Shen
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON INNOVATION & MANAGEMENT, VOLS I AND II, 2008, : 1752 - 1757
  • [33] Subaru Laser Guide Adaptive Optics System: Performance and Science Operation
    Minowa, Yosuke
    Hayano, Yutaka
    Terada, Hiroshi
    Pyo, Tae-Soo
    Oya, Shin
    Hattori, Masayuki
    Shirahata, Mai
    Takami, Hideki
    Guyon, Olivier
    Garrel, Vincent
    Colley, Stephen
    Weber, Mark
    Golota, Taras
    Watanabe, Makota
    Saito, Yoshihiko
    Ito, Meguru
    Iye, Masanori
    ADAPTIVE OPTICS SYSTEMS III, 2012, 8447
  • [34] Translation of genomics into routine cardiological practice: insights from a European Society of Cardiology Cardiovascular Round Table
    Dimmeler, Stefanie
    Ferri, Leticia
    Nioi, Paul
    O'Donnell, Christopher J.
    Damy, Thibaud
    Gomez-Outes, Antonio
    Giacca, Mauro
    Guo, Weinong
    Kavousi, Maryam
    Kupatt, Christian
    Landmesser, Ulf
    Schunkert, Heribert
    Zouridakis, Emmanouil
    Elliott, Perry M.
    EUROPEAN HEART JOURNAL, 2025,
  • [35] Development of stereo endoscope system with its innovative master interface for continuous surgical operation
    Myungjoon Kim
    Chiwon Lee
    Nhayoung Hong
    Yoon Jae Kim
    Sungwan Kim
    BioMedical Engineering OnLine, 16
  • [36] Innovative reverse osmosis system simplifies operation, saves costs for auto parts manufacturer
    Siemens Water Technologies, Colorado Springs, CO, United States
    不详
    Met. Finish., 2008, 11 (46):
  • [37] Development of stereo endoscope system with its innovative master interface for continuous surgical operation
    Kim, Myungjoon
    Lee, Chiwon
    Hong, Nhayoung
    Kim, Yoon Jae
    Kim, Sungwan
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [38] System studies of innovative development in the business sector of chemical science (1990–2014)
    A. M. Bessarabov
    N. N. Kulov
    A. V. Kvasyuk
    G. A. Zaremba
    Theoretical Foundations of Chemical Engineering, 2016, 50 : 1001 - 1014
  • [39] Towards an Innovative Computer Science & Technology Curriculum in UAE Public Schools System
    Al-Karaki, Jamal
    Harous, Saad
    Al-Muhairi, Hassan
    AlHammadi, Yousuf
    Ayyoub, Shadi
    AlShabi, Ammar
    AlZaabi, Hessa
    AlSalhi, Moza
    Salem, Sendyya
    AlAmiri, Amel
    PROCEEDINGS OF 2016 IEEE GLOBAL ENGINEERING EDUCATION CONFERENCE (EDUCON2016), 2016, : 883 - 891
  • [40] Special Issue: Innovative Solar System Science with the James Webb Space Telescope
    Mangum, Jeff
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2016, 128 (959)