[1] AIT Austrian Inst Technol GmbH, Safety & Secur Dept, A-8020 Graz, Austria
[2] Allgemeines Offentl Krankenhaus Elisabethine Linz, Linz, Austria
[3] Med Univ Graz, Dept Cardiol, Graz, Austria
来源
APPLIED CLINICAL INFORMATICS | 2010年 / 1卷 / 02期
关键词
Heart failure; telemedicine; mobile phone; eHealth; near field communication technology; HEART-FAILURE; PROGNOSIS;
D O I
10.4338/ACI-2009-12-RA-0021
中图分类号
R-058 [];
学科分类号
摘要
Objective: Results of the Austrian MOBITEL (MOBIle phone based TELemonitoring for heart failure patients) trial indicate that home-based telemonitoring improves outcome of chronic heart failure (CHF) patients and reduces both frequency and duration of hospitalizations. Based on lessons learned, we assessed the weak points to clear the way for routine operations. Methods: We analyzed the system with respect to recommendations of the ESC Guidelines and experiences gained throughout the trial to identify potential improvements. The following components have been identified: a patient terminal with highest usability, integrated way to document drug-intake and well-being, and automated event detection for worsening of CHF. As a consequence the system was extended by Near Field Communication (NFC) technology and by an event management tool. Results: Usability evaluation with 30 adults (14f, median 51y. IQR[45-65]) showed that 21 (8f) were able to immediately operate the system after reading a step-by-step manual. Eight (6f) needed one time demonstration and one man (80y) failed to operate the blood pressure meter. Routine operation of the revised system started in March 2009. Within 9 months, 15 patients (4f, median 74y. IQR[71-83], all NYHA-III) transmitted 17,149 items. 43 events were detected because of body weight gain of more then 2kg within 2 days. 49 therapy adjustments were documented. Three patients stopped using the system, two (1f) because of non-compliance and one (m, 82y) because of death. Overall, the rate of adherence to daily data transfer was 78%. Conclusion: First results confirm the applicability of the revised telemonitoring system in routine operation.
引用
收藏
页码:165 / 176
页数:12
相关论文
共 50 条
  • [1] Biosensor in cardiology. T-care project: a preliminary study on innovative wearable non-invasive telemonitoring system
    Amati, Francesca
    Santobuono, Vincenzo Ezio
    Bozza, Nicola
    Latorre, Maria
    Memeo, Riccardo
    Favale, Stefano
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0G)
  • [2] Biosensor in cardiology. T-care project: a preliminary study on innovative wearable non-invasive telemonitoring system
    Amati, Francesca
    Santobuono, Vincenzo Ezio
    Bozza, Nicola
    Latorre, Maria
    Memeo, Riccardo
    Favale, Stefano
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (SUPPL G)
  • [3] Improvement Science Increases Routine Lipid Screening in General Pediatric Cardiology
    Flyer, Jonathan N.
    Congdon, Elizabeth
    Yeager, Scott B.
    Drucker, Nancy
    Giddins, Niels G.
    Haxel, Caitlin S.
    Burstein, Danielle S.
    O'Connor, Kelsey H. C.
    Remy, Heather H.
    Terrien, Hannah E.
    Robinson, Keith J.
    JOURNAL OF PEDIATRICS, 2024, 273
  • [4] Innovative technologies in cardiology: from surprise to habit or forgetfulness
    Gilyarevskiy, S. R.
    Golshmid, M. V.
    Kuz'mina, I. M.
    RATIONAL PHARMACOTHERAPY IN CARDIOLOGY, 2015, 11 (04) : 404 - 412
  • [5] Telemonitoring system of television's operation state for elderly people living alone
    Nakajima, Kazuki
    Kamiya, Akinori
    Matsui, Hiroyuki
    Oikawa, Daisuke
    Fujita, Kentaro
    Higashi, Yuji
    Tamura, Toshiyo
    Fujimoto, Toshiro
    Sasaki, Kazuo
    PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-8, 2007, : 302 - +
  • [6] Monitoring System of the AMS Science Operation
    Zhang, Wenchao
    Shan, Baosong
    Choutko, Vitali
    Egorov, Alexander
    Eline, Alexandre
    23RD INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2018), 2019, 214
  • [7] Innovative bioventing system construction/operation in cold regions
    Stricklan, KK
    Mattzela, RL
    COLD REGIONS ENGINEERING: THE COLD REGIONS INFRASTRUCTURE: AN INTERNATIONAL IMPERATIVE FOR THE 21ST CENTURY, 1996, : 351 - 359
  • [8] Absorbed dose from daily routine practice in a nuclear cardiology laboratory
    Tosi, G.
    Marzo, K.
    Leonardi, L.
    Chiti, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S363 - S364
  • [9] ON COORDINATION OF SCIENCE AND BUSINESS INTERACTION IN REGIONAL INNOVATIVE SYSTEM
    Tatyana, Sannikova D.
    Zhanna, Aksenova N.
    TOMSK STATE UNIVERSITY JOURNAL, 2011, (345): : 162 - +
  • [10] Safe airport operation based on innovative magnetic detector system
    Gao, H.
    Heuer, Th.
    Dimitropoulos, K.
    Grammalidis, N.
    Weinmann, M.
    Huhnold, M.
    Astheimer, Th.
    Kirrane, P.
    Stockhammer, C.
    Kurz, A.
    Pfister, J.
    Hartmann, U.
    IET INTELLIGENT TRANSPORT SYSTEMS, 2009, 3 (02) : 236 - 244