Wind loading on tilted roof-top solar arrays: The parapet effect

被引:41
|
作者
Browne, Matthew T. L. [1 ]
Gibbons, Michael P. M. [1 ]
Gamble, Scott [1 ]
Galsworthy, Jon [1 ]
机构
[1] Rowan Williams Davies & Irwin Inc, Guelph, ON N1K 1B8, Canada
关键词
Wind loads; Solar arrays; Parapets; Low-rise buildings; Corner vortices; LOW BUILDINGS; PART;
D O I
10.1016/j.jweia.2013.08.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Scale model wind tunnel testing was used to investigate the effect of parapets on the wind loading of a roof-top solar array with a tilt angle of 10 degrees. Previous studies have indicated a correlation between parapet height and uplift wind loads acting on roof membranes and roof-top equipment. This relationship was reproduced in the current study for wind loads acting on roof-top solar arrays and is shown to be caused by building-induced aerodynamics, namely corner vortices. Increasing parapet height was shown to increase the peak wind loads acting on the array. These increases were found to be dependent on location on the roof, in the array, and geometry of the array itself. The parapet effect results in peak wind load increases for much of the array for typical parapet heights when all wind directions are considered. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:202 / 213
页数:12
相关论文
共 50 条
  • [41] Suitable Choice of Capacitor for a Self-excited Switched Reluctance Generator Driven by a Roof-Top Wind Turbine at Varying Wind Speeds
    Swagata Mapa
    G. Bhuvaneswari
    Transactions of the Indian National Academy of Engineering, 2022, 7 (1) : 259 - 267
  • [42] Roof-top solar energy potential under performance-based building energy codes: The case of Spain
    Izquierdo, Salvador
    Montanes, Carlos
    Dopazo, Cesar
    Fueyo, Norberto
    SOLAR ENERGY, 2011, 85 (01) : 208 - 213
  • [43] Wind loads on industrial solar panel arrays and supporting roof structure
    Wood, GS
    Denoon, RO
    Kwok, KCS
    WIND AND STRUCTURES, 2001, 4 (06) : 481 - 494
  • [44] Experimental Investigation of Wind Loads on Roof-Mounted Solar Arrays
    Yao, Jianfeng
    Tu, Zhibin
    Wang, Dong
    Shen, Guohui
    Lou, Wenjuan
    SUSTAINABILITY, 2022, 14 (14)
  • [45] Investigation into the effect of rounded building corner on wind loads of flat-roof-mounted solar arrays
    Dai, S. F.
    Liu, H. J.
    Peng, H. Y.
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [46] Influence of solar panel arrays on the wind loading of industrial roofs
    Wood, GS
    Denoon, RO
    Kwok, KCS
    Eddy, BJ
    Worrall, SJ
    FIRST INTERNATIONAL SYMPOSIUM ON WIND AND STRUCTURES FOR THE 21ST CENTURY, 2000, : 195 - 204
  • [47] Wind loading characteristics of solar arrays mounted on flat roofs
    Cao, Jinxin
    Yoshida, Akihito
    Saha, Proshit Kumar
    Tamura, Yukio
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2013, 123 : 214 - 225
  • [48] Techno-economic feasibility of grid-independent residential roof-top solar PV systems in Muscat, Oman
    Al-Saqlawi, Juman
    Madani, Kaveh
    Mac Dowell, Niall
    ENERGY CONVERSION AND MANAGEMENT, 2018, 178 : 322 - 334
  • [49] Networked microgrids with roof-top solar PV and battery energy storage to improve distribution grids resilience to natural disasters
    Galvan, Eric
    Mandal, Paras
    Sang, Yuanrui
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 123
  • [50] A Novel Active Anti-Islanding Protection Scheme for Grid-Interactive Roof-Top Solar PV System
    Varier, Rohith
    Pindoriya, Naran M.
    2014 EIGHTEENTH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2014,