Image Quality Comparison between Digital and Synthetic 2D Mammograms: A Qualitative and Quantitative Phantom Study

被引:2
|
作者
Barca, P. [1 ,2 ]
Lamastra, R. [1 ]
Caramella, D. [3 ]
Traino, A. C. [4 ]
Tucciariello, R. M. [1 ]
Fantacci, M. E. [1 ,2 ]
机构
[1] Univ Pisa, Dept Phys, Pisa, Italy
[2] Ist Nazl Fis Nucl, Pisa Sect, Pisa, Italy
[3] Univ Pisa, Dept Translat Res New Technol Med & Surg, Pisa, Italy
[4] Pisa Univ Hosp, Unit Med Phys, Azienda Osped Univ Pisana, Pisa, Italy
关键词
Synthesized Mammography; Digital Mammography; Image Quality; Modulation Transfer Function; Noise Power Spectrum; Contrast to Noise Ratio; ACR Phantom; BREAST TOMOSYNTHESIS; DIAGNOSTIC-ACCURACY; DBT;
D O I
10.5220/0007472401290136
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The recent introduction of digital breast tomosynthesis (DBT) have lead to improvements in sensitivity and specificity of breast cancer detection, especially in cases of tumors developed in dense breasts. Since DBT provides tomographic slices of an entire tissue volume, it reduces the inherent tissue overlapping limitation of digital mammography (DM). In addition, DBT combined with DM has been proven to decrease recall and increase invasive cancer detection rates in breast cancer screening. However, the employment of DBT+DM implies a not negligible increment of patients absorbed dose. Therefore, Synthesized mammograms (SMs) generated from the DBT data have been recently introduced to eliminate the need of an additional DM. However, several studies showed differences between DM and SM images and some studies found contrasting results in terms of image quality when DM and SM images were compared. In our phantom study, we objectively compare image quality of SM and DM images in terms of noise, spatial resolution and contrast properties. Additionally, a qualitative analysis of the ACR mammographic phantom was performed in both modalities to assess the detectability of different features. SM images were characterized by different texture with respect to DM images, showing lower overall performances in terms of contrast-to-noise ratio and modulation transfer function. However, the goal of SM images is to provide a useful two-dimensional guide complementary to the DBT dataset and the performances in terms of high-contrast features detectability were satisfactory in comparison to those obtained in DM.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 50 条
  • [1] Image Quality Comparison between Synthetic 2D Mammograms Obtained with 15° and 40° X-ray Tube Angular Range: A Quantitative Phantom Study
    Lamastra, R.
    Barca, P.
    Bisogni, M. G.
    Caramella, D.
    Rosso, V
    Tucciariello, R. M.
    Traino, A. C.
    Fantacci, M. E.
    PROCEEDINGS OF THE 13TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 2: BIOIMAGING, 2020, : 184 - 191
  • [2] Comparison Between Digital and Synthetic 2D Mammograms in Breast Density Interpretation
    Alshafeiy, Taghreed I.
    Wadih, Antoine
    Nicholson, Brandi T.
    Rochman, Carrie M.
    Peppard, Heather R.
    Patrie, James T.
    Harvey, Jennifer A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (01) : W36 - W41
  • [3] Evaluation of a computer-aided detection (CAD)-enhanced 2D synthetic mammogram: comparison with standard synthetic 2D mammograms and conventional 2D digital mammography
    James, J. J.
    Giannotti, E.
    Chen, Y.
    CLINICAL RADIOLOGY, 2018, 73 (10) : 886 - 892
  • [4] Ultrasound grayscale image quality comparison between a 2D intracavitary transducer and a 3D intracavitary transducer used in 2D mode: A phantom study
    Zhou, Wei
    Long, Zaiyang
    Tradup, Donald J.
    Stekel, Scott F.
    Browne, Jacinth E.
    Brown, Douglas L.
    Hangiandreou, Nicholas J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 134 - 140
  • [5] A qualitative and quantitative assessment of cardiac cine Phase contrast MRI: comparison of image quality between 2D and 3D acquisition
    Munemura Suzuki
    Takahiko Nakazono
    Ken Yamaguchi
    Kiyoshi Dogomori
    Yoshiaki Komori
    Norihiko Kotooka
    Koichi Node
    Hiroyuki Irie
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [6] 3D mammograms: Are they superior to 2D digital mammograms?
    Cox, Drew
    Nakonechnaya, Kristina
    Otondi, Chrispin
    Wright, Alene
    ANNALS OF SURGICAL ONCOLOGY, 2022, 29 (SUPPL 1) : 156 - 157
  • [7] Comprehensive assessment of image quality in synthetic and digital mammography: a quantitative comparison
    Patrizio Barca
    Rocco Lamastra
    Giacomo Aringhieri
    Raffaele Maria Tucciariello
    Antonio Traino
    Maria Evelina Fantacci
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 1141 - 1152
  • [8] Comprehensive assessment of image quality in synthetic and digital mammography: a quantitative comparison
    Barca, Patrizio
    Lamastra, Rocco
    Aringhieri, Giacomo
    Tucciariello, Raffaele Maria
    Traino, Antonio
    Fantacci, Maria Evelina
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 1141 - 1152
  • [9] Technical evaluation of image quality in synthetic mammograms obtained from 15° and 40° digital breast tomosynthesis in a commercial system: a quantitative comparison
    Patrizio Barca
    Rocco Lamastra
    Raffaele Maria Tucciariello
    Antonio Traino
    Carolina Marini
    Giacomo Aringhieri
    Davide Caramella
    Maria Evelina Fantacci
    Physical and Engineering Sciences in Medicine, 2021, 44 : 23 - 35
  • [10] Technical evaluation of image quality in synthetic mammograms obtained from 15° and 40° digital breast tomosynthesis in a commercial system: a quantitative comparison
    Barca, Patrizio
    Lamastra, Rocco
    Tucciariello, Raffaele Maria
    Traino, Antonio
    Marini, Carolina
    Aringhieri, Giacomo
    Caramella, Davide
    Fantacci, Maria Evelina