Detection of high-intensity focused ultrasound liver lesions using dynamic elastometry

被引:43
|
作者
Shi, XG
Martin, RW
Rouseff, D
Vaezy, S
Crum, LA
机构
[1] Univ Washington, Bioengn Lab, Seattle, WA 98195 USA
[2] Univ Washington, Anesthesiol Lab, Seattle, WA 98195 USA
[3] Univ Washington, Appl Phys Lab, Seattle, WA 98195 USA
关键词
Doppler; dynamic elastometry; HIFU; lesion detection; liver; stiffness; strain; stress; ultrasound; vibration; Young's modulus;
D O I
10.1177/016173469902100203
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A novel ultrasound technique was developed for detecting the distribution of stiffness in biological tissue. The method, which we call 'dynamic elastometry,' involves applying a low-frequency vibration (less than or equal to 5 Hz) to the tissue and measuring the resulting velocity pattern within the sample using Doppler spectral analysis. Based upon the velocity differences, an elastically stiff region can be differentiated from surrounding soft tissue. Dynamic elastometry was used to both detect and quantify lesions produced by high-intensity focused ultrasound (HIFU) in porcine livers. Measurements of the lesion position and length agreed well with independent geometric measurements. The mean and standard deviation of the differences between the two types of measurement were -0.01 cm and 0.10 cm for lesion position, and -0.05 cm and 0.12 cm for lesion length, respectively. The relative stiffness between lesions and normal liver tissue was estimated by the velocity gradient ratio. Results were compared with the Young's modulus ratios between lesion and normal liver tissue obtained from mechanical measurement. The dynamic elastometric estimates had a strong linear correlation with the mechanical measurements (r = 0.93) but were smaller than the latter by 26%.
引用
收藏
页码:107 / 126
页数:20
相关论文
共 50 条
  • [41] EFFECT OF BLOOD PERFUSION ON THE ABLATION OF LIVER PARENCHYMA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    CHEN, L
    TERHAAR, G
    HILL, CR
    DWORKIN, M
    CARNOCHAN, P
    YOUNG, H
    BENSTED, JPM
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (11): : 1661 - 1673
  • [42] Modeling for Quantitative Analysis of Nakagami Imaging in Accurate Detection and Monitoring of Therapeutic Lesions by High-Intensity Focused Ultrasound
    Han, Meng
    Song, Weidong
    Zhang, Fengshou
    Li, Zhenwei
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (07): : 1575 - 1585
  • [44] High-intensity focused ultrasound as a treatment for colorectal liver metastasis in difficult position
    Tan To Cheung
    Ronnie Tung Ping Poon
    Thomas Yau
    Dickson Sing Fung Tsang
    Chung Mau Lo
    Sheung Tat Fan
    International Journal of Colorectal Disease, 2012, 27 : 987 - 988
  • [45] High-intensity focused ultrasound as a treatment for colorectal liver metastasis in difficult position
    Cheung, Tan To
    Poon, Ronnie Tung Ping
    Yau, Thomas
    Tsang, Dickson Sing Fung
    Lo, Chung Mau
    Fan, Sheung Tat
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2012, 27 (07) : 987 - 988
  • [46] Treatment of localized prostate cancer using high-intensity focused ultrasound
    Uchida, T
    Ohkusa, H
    Nagata, Y
    Hyodo, T
    Satoh, T
    Irie, A
    BJU INTERNATIONAL, 2006, 97 (01) : 56 - 61
  • [47] EXTRACARDIAC ABLATION OF VENTRICULAR MYOCARDIUM USING HIGH-INTENSITY FOCUSED ULTRASOUND
    STRICKBERGER, SA
    SEIP, R
    BOGUN, F
    EBBINI, E
    MORADY, F
    CAIN, C
    CIRCULATION, 1995, 92 (08) : 3274 - 3274
  • [48] Noninvasive Lipoma Size Reduction Using High-Intensity Focused Ultrasound
    Shemer, Avner
    Brawer, Solli
    Amichi, Boaz
    Azhari, Haim
    DERMATOLOGIC SURGERY, 2013, 39 (10) : 1446 - 1451
  • [50] In vitro ablation of cardiac valves using high-intensity focused ultrasound
    Otsuka, R
    Fujikura, K
    Hirata, K
    Pulerwitz, T
    Oe, Y
    Suzuki, T
    Sciacca, R
    Marboe, C
    Wang, J
    Burkhoff, D
    Muratore, R
    Lizzi, FL
    Homma, S
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (01): : 109 - 114