Stator Flux Active Damping Methods for Field-Oriented Doubly Fed Induction Generator

被引:33
|
作者
Marques, G. D. [1 ]
Sousa, Duarte M. [1 ]
机构
[1] Univ Tecn Lisboa, Dept Elect & Comp Engn, P-1049001 Lisbon, Portugal
关键词
Doubly fed induction generator (DFIG); flux stabilization; induction generator;
D O I
10.1109/TEC.2012.2204887
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The doubly fed induction generator is characterized by natural stator flux oscillations with small damping. It has an unstable region when it is controlled with stator flux orientation with impressed rotor currents. Several techniques can be used for the stabilization and damping of this system. This paper describes, analyses, and compares three methods. The first method consists in lowering the bandwidth of the rotor current controllers. It has the disadvantage of allowing high rotor-disturbance currents during stator flux disturbances. The second method, the back-ims method, uses higher bandwidth control loops and corrects the direct rotor current reference proportionally to the derivative of the flux. It has good performances in steady state but uses considerable additional rotor currents to damp the system when transients occur. The third method, the two-axes damping system, is based on the correction of the dq rotor current references proportionally to the variations of the system variables, i.e., the stator flux and the so-called a angle. When compared with the back-ims method, the two-axes damping method uses smaller additional damping currents. Experimental verification based on a small laboratory prototype is presented.
引用
收藏
页码:799 / 806
页数:8
相关论文
共 50 条
  • [21] Field-oriented controlled induction generator with loss minimization
    Leidhold, R
    Garcia, G
    Valla, MI
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2002, 49 (01) : 147 - 156
  • [22] Stator-Flux-Linkage-Referenced Control and Online Optimization of a Doubly-Fed Induction Generator
    Kastelan, David
    Rudolph, Joachim
    Gensior, Albrecht
    2016 IEEE 7TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2016,
  • [23] Stator flux observing and speed estimation of a doubly fed induction generator based on least-order
    Cui, X.
    Ying, L. A.
    Liu, H. J.
    Liao, Q. F.
    Le, L. C.
    DYNAMICS OF CONTINUOUS DISCRETE AND IMPULSIVE SYSTEMS-SERIES B-APPLICATIONS & ALGORITHMS, 2006, 13E : 2757 - 2761
  • [24] Variable speed field-oriented controlled induction generator
    Leidhold, R
    Garcia, G
    CONFERENCE RECORD OF THE 1998 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3, 1998, : 540 - 546
  • [25] Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder
    Hopfensperger, B
    Atkinson, DJ
    Lakin, RA
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2000, 147 (04): : 241 - 250
  • [26] Grid-Flux-Oriented Control and Synchronization for a Doubly-Fed Induction Generator System
    Mueangngoen, Sutthimat
    Kumsuwan, Yuttana
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 1257 - 1262
  • [27] Harmonic damping based improvement strategy for suppressing stator harmonic current of doubly-fed induction generator
    Xie Z.
    Li H.
    Zhang X.
    Yang S.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2016, 40 (16): : 118 - 124
  • [28] Stator current harmonics analysis of doubly-fed induction generator
    Wang, Zhong
    Sun, Yuanzhang
    Li, Guojie
    Li, Zhiguo
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (06): : 1 - 5
  • [29] Steady state analysis of stator cascaded doubly fed induction generator
    Adarnowicz, Marek
    Strzelecki, Ryszard
    Wojciechowski, Daniel
    2007 COMPATIBILITY IN POWER ELECTRONICS, 2007, : 263 - 267
  • [30] Performance analysis of a doubly fed twin stator cage induction generator
    Runcos, F.
    Carlson, R.
    Sadowski, N.
    Kuo-Peng, P.
    RECENT DEVELOPMENTS OF ELECTRICAL DRIVES, 2006, : 361 - +