When one examines reviews regarding diagnostic allergy testing, it generally is noted that the advantage of skin testing is that it uses testing to an end organ, is less expensive, is more sensitive, and provides immediate results, which are easily visualized by the patient. In the case of in vitro testing, it is thought to be more helpful for patients with dermographia or widespread dermatitis, is not affected by H-1 or H-2 antagonists, and is thought to be safer than skin testing. This may not be entirely correct because studies actually demonstrated phlebotomy to be associated with more morbidity than skin-prick testing. Other concerns regarding both tests include allergen quality, the need from proficiency testing, and the fact that these tests should be used for corroborating a diagnosis as opposed to a screening test for allergy.
引用
收藏
页码:362 / 364
页数:3
相关论文
共 50 条
  • [1] The Great Debate-Testing
    Khatua, Sandeep
    Rich, Elliot
    Lane, Charles Chuck
    [J]. AATCC REVIEW, 2009, 9 (07) : 4 - 5
  • [2] Diagnosis of pyrazolone drug sensitivity: Clinical history versus skin testing and in vitro testing
    Kowalski, ML
    Bienkiewicz, B
    Woszczek, G
    Iwaszkiewicz, J
    Poniatowska, M
    [J]. ALLERGY AND ASTHMA PROCEEDINGS, 1999, 20 (06) : 347 - 352
  • [3] In vitro permeation testing for the evaluation of drug delivery to the skin
    Lane, Majella E.
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2024, 201
  • [4] Skin testing versus radioallergosorbent testing for indoor allergens
    Chinoy B.
    Yee E.
    Bahna S.L.
    [J]. Clinical and Molecular Allergy, 3 (1)
  • [5] Selection of Chemicals for the Development and Evaluation of In Vitro Methods for Skin Sensitisation Testing
    Casati, Silvia
    Aeby, Pierre
    Kimber, Ian
    Maxwell, Gavin
    Ovigne, Jean Marc
    Roggen, Erwin
    Rovida, Costanza
    Tosti, Luca
    Basketter, David
    [J]. ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2009, 37 (03): : 305 - 312
  • [6] Selection of chemicals for the development and evaluation of in vitro methods for skin sensitisation testing
    Rovida, Costanza
    Aeby, Pierre
    Basketter, David
    Kimber, Ian
    Maxwell, Gavin
    Roggen, Erwin
    Casati, Silvia
    [J]. TOXICOLOGY LETTERS, 2007, 172 : S92 - S93
  • [7] Skin constructs for replacement of skin tissues for in vitro testing
    Ponec, M
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 2002, 54 : S19 - S30
  • [8] EVALUATION OF ELECTROPHORETIC METHOD OF SKIN TESTING
    WALZER, A
    GOLAN, H
    [J]. JOURNAL OF ALLERGY, 1949, 20 (01): : 77 - 77
  • [9] Evaluation of a Tuberculosis Skin Testing Program
    Kahn, Pamela
    [J]. JOURNAL OF SCHOOL NURSING, 2009, 25 (01): : 48 - 54
  • [10] Evaluation of devices for skin prick testing
    Nelson, HS
    Lahr, J
    Buchmeier, A
    McCormick, D
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1998, 101 (02) : 153 - 156