Determining early adhesion of cells on polysaccharides/PCL surfaces by a quartz crystal microbalance

被引:5
|
作者
Chung, Tze-Wen [1 ]
Tyan, Yu-Chang [2 ,3 ]
Lee, Rong-Ho [4 ]
Ho, Chia-Wei [1 ]
机构
[1] Natl Yunlin Univ Sci & Technol, Dept Chem & Mat Engn, Touliu 64002, Yunlin, Taiwan
[2] Kaohsiung Med Univ, Dept Med Imaging & Radiol Sci, Kaohsiung, Taiwan
[3] Natl Sun Yat Sen Univ Kaohsiung Med Univ Joint Re, Kaohsiung, Taiwan
[4] Natl Chung Hsin Univ, Dept Chem Engn, Taichung, Taiwan
关键词
HYALURONAN; CARTILAGE;
D O I
10.1007/s10856-012-4764-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The early adhesions of cells to various biopolymers are important to their growths and proliferations. Here, the adhesion of cells (e.g., fibroblasts) on the electrode of a quartz crystal microbalance (QCM) that was coated by PCL or PEG/PCL and further adsorbed by chitosan (CS) or CS/hyaluronic acid (HA) layers, was examined by cell-counting technique, QCM method and MTS assay under a serum-free condition for 3 h. The surfaces on electrodes of the QCM were confirmed to have been modified by measuring their contact angles, FT-IR spectra and the weights of biopolymers affected the frequency shifts of the QCM. Among tested surfaces on electrodes, the adhesion of fibroblasts on a HA/CS/PCL surface was the most (e.g., 3.08 x 10(5) cells/cm(2)) while that on a PEG/PCL surface was the least (e.g., 0.7 x 10(5) cells/cm(2)), as determined by cell-counting technique. The frequency shift and the mass of adhering fibroblasts on HA/CS/PCL electrodes were -3,537 +/- A 770 Hz and 3.78 +/- A 0.22 mu g (n = 3), respectively, that were significantly exceeded those on other electrodes (-393 +/- A 58 Hz and 0.32 +/- A 0.06 mu g, n = 3, respectively, for PEG/PCL electrodes). These results were consistent with cell-counting technique. Although MTS assay yielded similar results, it was less sensitive than the two aforementioned methods. In conclusion, modified electrodes of a QCM provide a convenient and sensitive method for examining the early adhesion of cells (e.g., 3 h) to biopolymer surfaces.
引用
收藏
页码:3067 / 3073
页数:7
相关论文
共 50 条
  • [21] Characterization of heparin surfaces using photoelectron spectroscopy and quartz crystal microbalance
    Kristensen, EME
    Rensmo, H
    Larsson, R
    Siegbahn, H
    BIOMATERIALS, 2003, 24 (23) : 4153 - 4159
  • [22] MEASUREMENT OF INTERFACIAL PROCESSES AT ELECTRODE SURFACES WITH THE ELECTROCHEMICAL QUARTZ CRYSTAL MICROBALANCE
    BUTTRY, DA
    WARD, MD
    CHEMICAL REVIEWS, 1992, 92 (06) : 1355 - 1379
  • [23] Quartz crystal microbalance with rigid mass partially attached on electrode surfaces
    Lu, F
    Lee, HP
    Lim, SP
    SENSORS AND ACTUATORS A-PHYSICAL, 2004, 112 (2-3) : 203 - 210
  • [24] Quartz crystal microbalance expanded capability for studying CuCl crystal formation on copper surfaces
    Soares, DM
    Wasle, S
    Doblhofer, K
    Tenan, MA
    CHEMPHYSCHEM, 2002, 3 (09) : 817 - +
  • [25] Application of the Quartz Crystal Microbalance to the Study of Multivalent Carbohydrate-Carbohydrate Adhesion
    Rodriguez-Segui, S. A.
    Bucior, I.
    Burger, M. M.
    Errachid, A.
    Fernandez-Busquets, X.
    SENSOR LETTERS, 2009, 7 (05) : 782 - 787
  • [26] Monosacchride arrays for the detection of bacterial adhesion by use of Quartz Crystal microbalance technique
    Huang, Mingchuan
    Zhang, Yun
    Wang, Peng George
    Zeng, Xiangqun
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [27] Specific adhesion of vesicles monitored by scanning force microscopy and quartz crystal microbalance
    Pignataro, B
    Steinem, C
    Galla, HJ
    Fuchs, H
    Janshoff, A
    BIOPHYSICAL JOURNAL, 2000, 78 (01) : 487 - 498
  • [28] Extracellular matrix remodelling during cell adhesion monitored by the quartz crystal microbalance
    Lord, Megan S.
    Modin, Charlotte
    Foss, Morten
    Duch, Mogens
    Simmons, Anne
    Pedersen, Finn S.
    Besenbacher, Flemming
    Milthorpe, Bruce K.
    BIOMATERIALS, 2008, 29 (17) : 2581 - 2587
  • [29] DETECTION OF CELL-ADHESION BEHAVIORS BY USING A QUARTZ-CRYSTAL MICROBALANCE
    EBATO, H
    OKAHATA, Y
    MATSUDA, T
    KOBUNSHI RONBUNSHU, 1993, 50 (06) : 463 - 469
  • [30] Probing interparticle adhesion of dry and wet granular materials with the quartz crystal microbalance
    Johannsmann, Diethelm
    d'Amour, Nelson J.
    Kanazawa, Kay K.
    Stalgren, Johan J. R.
    Frank, Curt. W.
    Rodahl, M.
    PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND EXPOSITION, VOLS 1 AND 2, 2006, : 550 - +