Determining early adhesion of cells on polysaccharides/PCL surfaces by a quartz crystal microbalance

被引:5
|
作者
Chung, Tze-Wen [1 ]
Tyan, Yu-Chang [2 ,3 ]
Lee, Rong-Ho [4 ]
Ho, Chia-Wei [1 ]
机构
[1] Natl Yunlin Univ Sci & Technol, Dept Chem & Mat Engn, Touliu 64002, Yunlin, Taiwan
[2] Kaohsiung Med Univ, Dept Med Imaging & Radiol Sci, Kaohsiung, Taiwan
[3] Natl Sun Yat Sen Univ Kaohsiung Med Univ Joint Re, Kaohsiung, Taiwan
[4] Natl Chung Hsin Univ, Dept Chem Engn, Taichung, Taiwan
关键词
HYALURONAN; CARTILAGE;
D O I
10.1007/s10856-012-4764-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The early adhesions of cells to various biopolymers are important to their growths and proliferations. Here, the adhesion of cells (e.g., fibroblasts) on the electrode of a quartz crystal microbalance (QCM) that was coated by PCL or PEG/PCL and further adsorbed by chitosan (CS) or CS/hyaluronic acid (HA) layers, was examined by cell-counting technique, QCM method and MTS assay under a serum-free condition for 3 h. The surfaces on electrodes of the QCM were confirmed to have been modified by measuring their contact angles, FT-IR spectra and the weights of biopolymers affected the frequency shifts of the QCM. Among tested surfaces on electrodes, the adhesion of fibroblasts on a HA/CS/PCL surface was the most (e.g., 3.08 x 10(5) cells/cm(2)) while that on a PEG/PCL surface was the least (e.g., 0.7 x 10(5) cells/cm(2)), as determined by cell-counting technique. The frequency shift and the mass of adhering fibroblasts on HA/CS/PCL electrodes were -3,537 +/- A 770 Hz and 3.78 +/- A 0.22 mu g (n = 3), respectively, that were significantly exceeded those on other electrodes (-393 +/- A 58 Hz and 0.32 +/- A 0.06 mu g, n = 3, respectively, for PEG/PCL electrodes). These results were consistent with cell-counting technique. Although MTS assay yielded similar results, it was less sensitive than the two aforementioned methods. In conclusion, modified electrodes of a QCM provide a convenient and sensitive method for examining the early adhesion of cells (e.g., 3 h) to biopolymer surfaces.
引用
收藏
页码:3067 / 3073
页数:7
相关论文
共 50 条
  • [1] Determining early adhesion of cells on polysaccharides/PCL surfaces by a quartz crystal microbalance
    Tze-Wen Chung
    Yu-Chang Tyan
    Rong-Ho Lee
    Chia-Wei Ho
    Journal of Materials Science: Materials in Medicine, 2012, 23 : 3067 - 3073
  • [2] Study of Bacterial Adhesion on Different Glycopolymer Surfaces by Quartz Crystal Microbalance with Dissipation
    Wang, Yinan
    Narain, Ravin
    Liu, Yang
    LANGMUIR, 2014, 30 (25) : 7377 - 7387
  • [3] Adhesion of liposomes:: a quartz crystal microbalance study
    Lüthgens, E
    Herrig, A
    Kastl, K
    Steinem, C
    Reiss, B
    Wegener, J
    Pignataro, B
    Janshoff, A
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (11) : 1865 - 1875
  • [4] Using adhesion to probe viscoelasticity of polymer film surfaces: A quartz crystal microbalance study
    J.A. Forrest
    J. Mattsson
    L. Börjesson
    The European Physical Journal E, 2002, 8 : 129 - 136
  • [5] Using adhesion to probe viscoelasticity of polymer film surfaces:: A quartz crystal microbalance study
    Forrest, JA
    Mattsson, J
    Börjesson, L
    EUROPEAN PHYSICAL JOURNAL E, 2002, 8 (02): : 129 - 136
  • [6] Quartz crystal microbalance study of protein adsorption on natural polysaccharides
    Engineering Center of Artificial Organ and Materials, Department of Material Science and Engineering, Jinan University, Guangzhou 510632, China
    Gongneng Cailiao, 2009, 2 (287-290):
  • [7] Acoustic detection of cell adhesion on a quartz crystal microbalance
    Da-Silva, Ana-Carina
    Rodrigues, Rogerio
    Rosa, Luis F. M.
    de-Carvalho, Jorge
    Tome, Brigitte
    Ferreira, Guilherme N. M.
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2012, 59 (06) : 411 - 419
  • [8] SPECTROELECTROCHEMICAL QUARTZ CRYSTAL MICROBALANCE STUDIES OF ELECTRODE SURFACES
    ARBUCKLE, GA
    CHENG, RR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 163 - COLL
  • [9] BACTERIAL IMMOBILIZATION AT GOLD SURFACES - DETECTION WITH THE QUARTZ CRYSTAL MICROBALANCE
    FAXON, AR
    BUTTRY, DA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 324 - COLL
  • [10] Chiral Recognition on Bare Gold Surfaces by Quartz Crystal Microbalance
    Xiao, Xiangyun
    Chen, Chao
    Zhang, Yehao
    Kong, Huihui
    An, Rong
    Li, Shuang
    Liu, Wei
    Ji, Qingmin
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2021, 60 (47) : 25028 - 25033