Evaluation of erosion risk at the base of an electric power transmission line

被引:0
|
作者
deCarvalho, JC
Pereira, JHF
Guimaraes, RC
dosSantos, RMM
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Brazilian Federal District is covered by a porous, collapsible tropical soil layer with thickness that can reach 30 meters. Below this layer it can usually be found a stratum of saprolite over slate or metarrythymites strata. Commonly the water table is found at the contact between the porous soil and the saprolite. It is common in this region for the occurrence of gullies and piping. In many cases the piping mechanism is triggered by an increase in surficial water hydraulic gradient in regions of gullies due to the combined action of gradient increase and water table lowering. In view of the regional aspects presented above, this work describes the evaluation of the possibility of a gully reaching an electric power transmission line in its final stage of construction. Studies on the possibility of the gully to move towards the transmission line ii were carried out as well as a surveying on the water table in the area and the direction of the groundwater flow. Laboratory tests were also performed to study the soils in the region, such as soil classification tests and erodibility tests (double-sedimentation, pinhole and Inderbitzen tests). This study indicates that there are no risks for the transmission electric power line being affected by the piping mechanism in the existing erosion process (i.e., gully).
引用
下载
收藏
页码:29 / 44
页数:16
相关论文
共 50 条
  • [21] Lightning Activity Analysis and Risk Evaluation of Transmission Line
    Hu, Min
    Huang, Xuwei
    2011 INTERNATIONAL CONFERENCE ON QUALITY, RELIABILITY, RISK, MAINTENANCE, AND SAFETY ENGINEERING (ICQR2MSE), 2011, : 158 - 161
  • [22] Evaluation method of performance index for on-line control of high voltage electric power system of generation and transmission
    Cuccia, P.
    Giangualano, M.
    Energia Elettrica, 1991, 68 (02):
  • [23] Electric Power Transmission
    不详
    LIBRARY JOURNAL, 1948, 73 (10) : 823 - 823
  • [24] The Efficiency Evaluation of Electric Power Market Considering Transmission Congestion
    Liu Wei
    Zhang Jing
    Zeng Ming
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 2258 - 2261
  • [25] Comprehensive Evaluation Research on Electric Power Transmission and Transformation Project
    Wen, Lei
    Bai, Lu
    Liu, Yan-Jun
    2015 2ND INTERNATIONAL CONFERENCE ON SOCIAL SCIENCE (ICSS 2015), 2015, : 409 - 414
  • [26] Overload Risk Assessment of Power Transmission Line Considering Dynamic Line Rating
    Ding Z.
    Yu K.
    Wang C.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (09): : 146 - 152
  • [27] Cascading structural failures of towers in an electric power transmission line due to straight line winds
    Dikshit, Saransh
    Dobson, Ian
    Alipour, Alice
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2024, 250
  • [28] Channel evaluation for power line communication in plug - in electric vehicles
    Barmada, S.
    Raugi, M.
    Rizzo, R.
    Tucci, M.
    IET ELECTRICAL SYSTEMS IN TRANSPORTATION, 2012, 2 (04) : 195 - 201
  • [29] Experimental Evaluation of Power Differential Relay for Transmission Line Protection
    Darwish, H. A.
    Taalab, A. -M.
    Ahmed, E. S.
    Malik, O. P.
    2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 1279 - +
  • [30] Risk Evaluation Method of Electric Power Communication Network
    Jiang, Kangming
    Zeng, Ying
    Deng, Boren
    Tang, Liangrui
    2013 NINTH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION (ICNC), 2013, : 1595 - 1599