Reduced Optical Path Length in the Vastus Lateralis During Ramp Cycling Exercise

被引:2
|
作者
Endo, Tasuki [1 ]
Kime, Ryotaro [1 ]
Watanabe, Tsubasa [1 ]
Fuse, Sayuri [1 ]
Murase, Norio [1 ]
Kurosawa, Yuko [1 ]
Hamaoka, Takafumi [1 ]
机构
[1] Tokyo Med Univ, Dept Sports Med Hlth Promot, Shinjuku Ku, Tokyo, Japan
来源
关键词
Optical path length; Ramp cycling exercise; Muscle deoxygenation; Near-infrared time-resolved spectroscopy; Endurance trained athlete; MUSCLE; SPECTROSCOPY; PATHLENGTH; TISSUE;
D O I
10.1007/978-3-030-34461-0_30
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Near-infrared time-resolved spectroscopy (NIRTRS) can quantitatively evaluate mean optical path length (MPL). Since an increase in optical absorbers in the NIR region (e.g. an increase in deoxygenated hemoglobin during exercise) would shorten the MPL, the NIRS measurement area may vary depending on physical and physiological characteristics of the measurement region and/or the exercise intensity. The aim of this study was to examine the changes in MPL measured by NIRTRS during ramp cycling exercise between fat layer thickness-matched subjects with different aerobic capacities. Healthy control (CON, n = 8) and endurance-trained males (TR, n = 8) performed ramp cycling exercise until exhaustion. Deoxygenated hemoglobin concentration (Deoxy-Hb), total hemoglobin concentration (Total-Hb) and oxygenated hemoglobin concentration (Oxy-Hb) were evaluated by a three-wavelength NIRTRS system. MPL in each wavelength (MPL760, MPL800 and MPL830) was monitored continuously. With increasing exercise intensity, Total- and Deoxy-Hb significantly increased and Oxy-Hb decreased in both groups. Total- and Oxy-Hb during exercise were significantly higher in TR than CON (P < 0.05, P < 0.01, respectively). Furthermore, Deoxy-Hb also tended to be higher in TR than CON (P = 0.07). In addition, MPL at all wavelengths significantly shortened with an increase in exercise intensity, with no differences between CON and TR. In particular, MPL760 at peak exercise shortened more than 10% compared to the start of exercise in both groups, even though MPL830 decreased only a few per cent. These findings suggest that the NIRS measurement area may be reduced during ramp cycling exercise due to shortened MPL. Additionally, the changes in MPL may be especially greater at 760 nm than at the other wavelengths due to greater changes in Deoxy-Hb during exercise. Furthermore, this study indicates that the measurements of muscle deoxygenation using continuous-wave NIRS can be less accurate since they are significantly affected by changes in the optical path length.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 50 条
  • [21] In vivo operational fascicle lengths of vastus lateralis during sub-maximal and maximal cycling
    Austin, Neal
    Nilwik, Rachel
    Herzog, Walter
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (12) : 2394 - 2399
  • [22] Effect of arm cranking on oxygenation of vastus lateralis and lateral gastrocnemius muscles during leg cycling
    Ogata, H
    Yano, T
    [J]. JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2005, 45 (03): : 257 - 263
  • [23] Gastrocnemius medialis and vastus lateralis oxygenation during whole-body vibration exercise
    Cardinale, Marco
    Ferrari, Marco
    Quaresima, Valentina
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (04): : 694 - 700
  • [24] Reliability Of Vastus Lateralis Oxygenation Measured By Near Infrared Spectroscopy During Resistance Exercise
    Pereira, Marta
    Gomes, Paulo Sergio C.
    Bhambhani, Yagesh
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S265 - S265
  • [25] ELECTRICAL-ACTIVITY OF VASTUS-LATERALIS DURING PEDALING EXERCISE ON A STATIONARY BICYCLE
    CAMUS, G
    MICHEL, P
    THYS, H
    LHERMEROUT, C
    MIHALY, MC
    [J]. JOURNAL DE PHYSIOLOGIE, 1987, 82 (03): : A2 - A2
  • [26] Comparative Bilateral Measurements of Vastus Lateralis Muscle Oxygen Desaturation Kinetics during 30 S Sprint Cycling Exercise: Effects of Age and Performance
    Reinpold, Karmen
    Rannama, Indrek
    Port, Kristjan
    [J]. JOURNAL OF FUNCTIONAL MORPHOLOGY AND KINESIOLOGY, 2024, 9 (02)
  • [27] Analysis of vastus lateralis and vastus medialis oblique muscle activation during squat exercise with and without a variety of tools in normal adults
    Lee, Tae-kyung
    Park, So-mi
    Yun, Sae-bom
    Lee, Ae-ran
    Lee, Yun-seob
    Yong, Min-sik
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2016, 28 (03) : 1071 - 1073
  • [28] Muscle activation of vastus medialis obliquus and vastus lateralis during a dynamic leg press exercise with and without isometric hip adduction
    Peng, Hsien-Te
    Kernozek, Thomas W.
    Song, Chen-Yi
    [J]. PHYSICAL THERAPY IN SPORT, 2013, 14 (01) : 44 - 49
  • [29] Operating length and velocity of human M. vastus lateralis fascicles during vertical jumping
    Nikolaidou, Maria Elissavet
    Marzilger, Robert
    Bohm, Sebastian
    Mersmann, Falk
    Arampatzis, Adamantios
    [J]. ROYAL SOCIETY OPEN SCIENCE, 2017, 4 (05): : 1 - 15
  • [30] Reduced oxygen desaturation in the vastus lateralis of chronic stroke survivors during graded muscle contractions
    Hyngstrom, Allison S.
    Nguyen, Jennifer N.
    Murphy, Spencer A.
    Raab, Stephanie C.
    Schmit, Brian D.
    Gutterman, David D.
    Durand, Matthew J.
    [J]. TOPICS IN STROKE REHABILITATION, 2024, 31 (05) : 513 - 526