Temperatures in unprotected joints between steel beams and concrete-filled tubular columns in fire

被引:29
|
作者
Ding, J. [1 ]
Wang, Y. C. [1 ]
机构
[1] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester M13 9PL, Lancs, England
关键词
Joints; Temperature calculation; Concrete-filled tubes; Fire tests; Section factor; Eurocode;
D O I
10.1016/j.firesaf.2008.02.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents experimental, numerical and analytical results of temperatures in different components of unprotected joints between steel beams and concrete-filled tubular columns in fire, which forms part of a research project to investigate joint behaviour under fire conditions and robustness of steel structures under accidental fire attack. Accurate calculation of connection temperatures is an essential first step of this process. The joint types include fin plate, endplate, reverse channel and T-stub. The results of the experiments indicate that the different components that are in the same region of a joint may be considered to have the same temperature. This suggests that the lumped mass temperature calculation equation in EN 1993-1-2 for unprotected steelwork may be used to calculate joint temperatures, by using an equivalent section factor for all the joint components in the same region of the joint. Therefore, the main objective of this study is to derive suitable expressions to calculate the section factors for the different components of the joints tested in this study. The experimental results have also been used to assess the simple temperature calculation method in Annex D of EN 1993-1-2, which relates the joint temperatures to the temperature of the connected beam. It has been found that this method generates grossly inaccurate results. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:16 / 32
页数:17
相关论文
共 50 条
  • [21] Analysis on the stress patterns of the joint between concrete-filled rectangular steel tubular columns and steel beams
    Department of Civil Engineering, Nanjing Institute of Technology, Nanjing 210009, China
    Gongcheng Lixue, 2006, 6 (114-119): : 114 - 119
  • [22] Seismic Performance of Reinforced Concrete Beam to Concrete-filled Steel Tubular Columns Joints
    Qu, Hui
    Han, Lin-Hai
    Tao, Zhong
    ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 685 - +
  • [23] Fire protection thickness of concrete-filled fire-resistant steel tubular columns
    Liu, Yi-Xiang
    Tong, Gen-Shu
    Zhang, Lei
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2015, 49 (12): : 2387 - 2396
  • [25] APPLICATION OF OPENSEES ON SIMULATING OF STEEL BEAM TO CONCRETE-FILLED STEEL TUBULAR COLUMNS JOINTS
    Qu, H.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON INSPECTION APPRAISAL REPAIRS AND MAINTENANCE OF STRUCTURES, VOLS 1 AND 2, 2010, : 921 - 924
  • [26] Experimental study on seismic performance of joints between concrete-filled square steel tubular special-shaped columns and steel beams
    Xue, Jian-Yang
    Chen, Xi
    Ge, Guang-Quan
    Hou, Wen-Long
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2011, 43 (SUPPL. 2): : 255 - 259
  • [27] Behaviour of flush end plate joints to concrete-filled steel tubular columns
    Wang, Jing-Feng
    Han, Lin-Hai
    Uy, Brian
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (04) : 925 - 939
  • [28] Behaviour of hybrid fibre reinforced concrete-filled steel tubular beams and columns
    Karuppanan, Kathiresan
    Govindasamy, Vennila
    MATERIA-RIO DE JANEIRO, 2020, 25 (01):
  • [29] Development of a Calculation Method for the Fire Design of Concrete-Filled Steel Tubular Columns
    Espinos, Ana
    Romero, Manuel L.
    Albert, Vicente
    Hospitaler, Antonio
    Bihina, Gisels
    Renaud, Christophe
    STRUCTURES IN FIRE, 2016, : 535 - 543
  • [30] Fire behavior and performance of concrete-filled steel tubular columns: Review and discussion
    Wang, J. H.
    He, J.
    Xiao, Y.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 157 : 19 - 31