It is a retrospective analytic study of 1,009 transpedicular screws (689 thoracic and 320 lumbosacral), inserted with free-hand technique in neuromuscular scoliosis using postoperative CT scan. The aim of paper was to determine the accuracy and safety of transpedicular screw placement with free-hand technique in neuromuscular scoliosis and to compare the accuracy at different levels in such population. All studies regarding accuracy and safety of pedicle screw in scoliosis represent idiopathic scoliosis using various techniques such as free-hand, navigation, image intensifier, etc., for screw insertion. Anatomies of vertebrae and pedicle are distorted in scoliosis, hence accurate and safe placement of pedicle screw is prerequisite for surgery. Between 2004 and 2006, 37 consecutive patients, average age 20 years (9-44 years), of neuromuscular scoliosis were operated with posterior pedicle screw fixation using free-hand technique. Accuracy of pedicle screws was studied on postoperative CT scan. Placement up to 2 mm medial side and 4 mm lateral side was considered within-safe zone. Of the 1,009 screws, 273 screws were displaced medially, laterally or on the anterior side showing that 73% screws (68% in thoracic and 82.5% in lumbar spine) were accurately placed within pedicle. Considering the safe zone, 93.3% (942/1009, 92.4% in thoracic and 95.3% in lumbar spine) of the screws were within the safe zone. Comparing accuracy according to severity of curve, accuracy was 75% in group 1 (curve < 90) and 69% in group 2 (curve > 90) with a safety of 94.8 and 91.2%, respectively (P = 0.35). Comparing the accuracy at different thoracic levels, it showed 67, 64 and 72% accuracy in upper, middle and lower thoracic levels with safety of 96.6, 89.2 and 93.1%, respectively, exhibiting no statistical significant difference (P = 0.17). Pedicle screw placement in neuromuscular scoliosis with free-hand technique is accurate and safe as other conditions.
引用
收藏
页码:1686 / 1696
页数:11
相关论文
共 50 条
  • [41] Free hand pedicle screw placement in the thoracic spine: Is it safe?
    Kim, YJ
    Lenke, LG
    Bridwell, KH
    Cho, YSS
    Riew, KD
    SPINE, 2004, 29 (03) : 333 - 342
  • [42] Accuracy and safety of thoracic pedicle screw placement in spinal deformities
    Smorgick, Y
    Millgram, MA
    Anekstein, Y
    Floman, Y
    Mirovsky, Y
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (06): : 522 - 526
  • [43] Accuracy of cervical pedicle screw placement using the funnel technique
    Karaikovic, EE
    Yingsakmongkol, W
    Gaines, RW
    SPINE, 2001, 26 (22) : 2456 - 2462
  • [44] Free-Hand Pedicle Screw Insertion of Thoracic Spine Using Fennell Technique: Initial Results and Review of Literature
    Satapathy, Ayusman
    Dash, Chinmaya
    Sharma, Arunav
    Sahu, Rabi Narayan
    INDIAN JOURNAL OF NEUROTRAUMA, 2019, 16 (01): : 10 - 13
  • [45] The Child's Age and the Size of the Curvature Do Not Affect the Accuracy of Screw Placement with the Free-Hand Technique in Spinal Deformities in Children and Adolescents
    Grabala, Pawel
    Helenius, Ilkka J.
    Kowalski, Piotr
    Grabala, Michal
    Zacha, Slawomir
    Deszczynski, Jaroslaw M.
    Albrewczynski, Tomasz
    Galgano, Michael A.
    Buchowski, Jacob M.
    Chamberlin, Kelly
    Shah, Suken A.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (12)
  • [46] Accuracy of "Free-Hand Technique" for Instrumentation of Thoracolumbar Spine
    Mattei, Tobias Alecio
    Milano, Jeronimo Buzetti
    NEUROSURGERY, 2011, 69 (01) : E265 - E266
  • [47] Accuracy of the Free-hand Placement of Pedicle Screws in the Lumbosacral Spine Using a Universal Entry Point Clinical Validation
    Miekisiak, Grzegorz
    Kornas, Piotr
    Lekan, Maciej
    Dacko, Wladyslaw
    Latka, Dariusz
    Kaczmarczyk, Jacek
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (04): : E194 - E198
  • [48] Accuracy and Safety of Pedicle Screw Placement for Treating Adolescent Idiopathic Scoliosis: A Narrative Review Comparing Available Techniques
    Ansorge, Alexandre
    Sarwahi, Vishal
    Bazin, Ludmilla
    Vazquez, Oscar
    De Marco, Giacomo
    Dayer, Romain
    DIAGNOSTICS, 2023, 13 (14)
  • [49] Usefulness and Radiological Evaluation of Accuracy of the Innovative "Smart" Hand Technique for Pedicle Screw Placement: An Anatomical Study
    Comert, Ayhan
    Dogan, Ihsan
    Caglar, Y. Sukru
    TURKISH NEUROSURGERY, 2018, 28 (06) : 866 - 876
  • [50] Pedicle screw piercer with warning device - A technique to increase accuracy of pedicle screw placement A cadaveric study
    Lin Bin
    He Yong
    Xu Yang
    Zhang Bi
    Sha Mo
    Guo Zhi-Min
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (06) : 545 - 549