Targeted microbubbles for imaging tumor angiogenesis: Assessment of whole-body biodistribution with dynamic micro-PET in mice

被引:145
|
作者
Willmann, Juergen K. [1 ,2 ]
Cheng, Zhen [1 ,2 ]
Davis, Corrine [3 ]
Lutz, Amelie M. [1 ,2 ]
Schipper, Meike L. [1 ,2 ]
Nielsen, Carsten H. [1 ,2 ]
Gambhir, Sanjiv S. [1 ,2 ,4 ]
机构
[1] Stanford Univ, Sch Med, Mol Imaging Program, Dept Radiol,James H Clark Ctr, Stanford, CA 94305 USA
[2] Stanford Univ, Sch Med, James H Clark Ctr, Bio X Program, Stanford, CA 94305 USA
[3] Stanford Univ, Sch Med, James H Clark Ctr, Dept Comparat Med, Stanford, CA 94305 USA
[4] Stanford Univ, Sch Med, James H Clark Ctr, Dept Bioengn, Stanford, CA 94305 USA
关键词
D O I
10.1148/radiol.2491072050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate in vivo whole-body biodistribution of microbubbles (MBs) targeted to tumor angiogenesis-related vascular endothelial growth factor (VEGF) receptor 2 (VEGFR2) by using dynamic micro-positron emission tomography (PET) in living mice. Materials and Methods: Animal protocols were approved by the Institutional Administrative Panel on Laboratory Animal Care. Lipid-shell perfluorocarbon-filled MBs, targeted to VEGFR2 via anti-VEGFR2 antibodies, were radiolabeled by conjugating the radiofluorination agent N-succinimidyl-4-[F-18]fluorobenzoate (SFB) to the anti-VEGFR2 antibodies. These MBs were then injected intravenously into nude mice (n = 4) bearing angiosarcomas, and the whole-body biodistribution of these probes was assessed for 60 minutes by using dynamic micro-PET. Results were compared with ex vivo gamma counting (n = 6) and immunofluorescence staining (n = 6). Control studies in angiosarcoma-bearing mice were performed with injection of the radiolabeled antibodies alone (n = 3) or free SFB (n = 3). A mixed-effects regression of MB accumulation on fixed effects of time and tissue type (tumor or muscle) and random effect of animal was performed. Results: VEGFR2-targeted MBs rapidly cleared from the blood circulation (50% blood clearance after approximately 3.5 minutes) and accumulated in the liver (mean, 33.4% injected dose [ID]/g +/- 13.7 [standard deviation] at 60 minutes) and spleen (mean, 9.3% ID/g +/- 6.5 at 60 minutes) on the basis of micro-PET imaging. These findings were confirmed with ex vivo gamma counting. Uptake of targeted MBs was significantly higher (P < .0001) in tumor than in adjacent skeletal muscle tissue. Immunofluorescence staining demonstrated accumulation of the targeted MBs within hepatic Kupffer cells and splenic macrophages. Biodistribution of the radiolabeled antibodies and free SFB differed from the distribution of the targeted MBs. Conclusion: Dynamic micro-PET allows assessment of in vivo biodistribution of VEGFR2-targeted MBs. (C) RSNA, 2008.
引用
收藏
页码:212 / 219
页数:8
相关论文
共 50 条
  • [21] Evaluation of [18F]Mefway biodistribution based on whole-body microPET imaging of mice
    Constantinescu, Cristian
    Garcia, Adriana
    Sevrioukov, Evegueni
    Pan, Min-Liang
    Mukherjee, Jogeshwar
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [22] Evaluation of [18F]Nifene biodistribution based on whole-body microPET imaging of mice
    Constantinescu, Cristian
    Garcia, Adriana
    Sevrioukov, Evegueni
    Pan, Min-Liang
    Mukherjee, Jogeshwar
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [23] Biodistribution and Radiation Dosimetry of 11C-Nicotine from Whole-Body PET Imaging in Humans
    Garg, Pradeep K.
    Lokitz, Stephen J.
    Nazih, Rachid
    Garg, Sudha
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (03) : 473 - 478
  • [24] Biodistribution and radiation dosimetry of [18F]-tetrafluoroborate as determined by whole-body PET imaging in primates
    Marti-Climent, J. M.
    Collantes, M.
    Jauregui-Osoro, M.
    Quincoces, G.
    Prieto, E.
    Bilbao, I.
    Ecay, M.
    Arbizu, J.
    Richter, J. A.
    Penuelas, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S328 - S329
  • [25] Design and Bio.evaluation of 64Cu-NOTA-Herceptin for Tumor Targeted Micro-PET Imaging
    Zhu Hua
    Li Yilin
    Zhao Chuanke
    Xie Qinghua
    Liu Fei
    Han Xuedi
    Gao Jing
    Xia Chuanqin
    Shen Lin
    Yang Zhi
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2016, 37 (12): : 2132 - 2137
  • [26] Clinical assessment of lesion detectability in dynamic whole-body PET imaging using compartmental and Patlak parametric mapping
    Zaker, Neda
    Kotasidis, Fotis
    Garibotto, Valentina
    Zaidi, Habib
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [27] Assessment of the biodistribution of an [18F]FDG-loaded perfluorocarbon double emulsion using dynamic micro-PET in rats
    Fabiilli, Mario L.
    Piert, Morand R.
    Koeppe, Robert A.
    Sherman, Phillip S.
    Quesada, Carole A.
    Kripfgans, Oliver D.
    CONTRAST MEDIA & MOLECULAR IMAGING, 2013, 8 (04) : 366 - 374
  • [28] High-throughput multiple-mouse imaging with micro-PET/CT for whole-skeleton assessment
    Yagi, Masashi
    Arentsen, Luke
    Shanley, Ryan M.
    Hui, Susanta K.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (07): : 849 - 853
  • [29] An analytic study of the effects of attenuation on tumor detection in whole-body PET oncology imaging
    Bai, CY
    Kinahan, PE
    Brasse, D
    Cormat, C
    Townsend, DW
    Meltzer, CC
    Villemagne, V
    Charron, M
    Defrise, M
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (11) : 1855 - 1861
  • [30] ECAT-III - A NEW PET SYSTEM FOR HEART AND WHOLE-BODY DYNAMIC IMAGING
    HOFFMAN, EJ
    PHELPS, ME
    HUANG, SC
    COLLARD, PE
    BIDAUT, LM
    SCHWAB, RL
    SCHWAIGER, M
    SCHELBERT, HR
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P28 - P28