Reproducibility of Quantitative Assessment of Altered Hepatic Hemodynamics With Dynamic Contrast-Enhanced Ultrasound

被引:9
|
作者
Gauthier, Thomas P. [1 ,2 ]
Muhammad, Aun [1 ]
Wasan, Harpreet S. [1 ]
Abel, Paul D. [1 ]
Leen, Edward L. S. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, London, England
[2] Philips Healthcare, Bothell, WA USA
关键词
blood flow quantification; contrast agents; liver malignancy; therapy response assessment; ultrasound; DOPPLER PERFUSION INDEX; QUANTIFICATION; METASTASES; AGREEMENT; THERAPY; US;
D O I
10.7863/jum.2012.31.9.1413
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The aim of this clinical study was to evaluate the reproducibility of quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound. Methods-Fifteen patients with colorectal liver metastases and 5 volunteers were studied. The hepatic artery proper and the portal vein were imaged simultaneously with dynamic contrast-enhanced ultrasound. The examination was repeated with 2 different contrast bolus volumes (1.2 and 2.4 mL), and time-intensity curves were formed from dynamic contrast-enhanced ultrasound image loops. The rise time, peak intensity, and wash-in slope were derived from hepatic artery and portal vein time-intensity curves. Inter-reader, intra-reader, and inter-scan agreement was assessed by 2 independent readers. Quantitative (intraclass correlation coefficients and coefficients of variation [CVs]) and qualitative (Landis and Koch classification) analyses were performed. Results-Intra-reader and inter-reader agreement was "almost perfect" for the hepatic artery (CV, 10%-15% and 8%-9%, respectively), portal vein (CV, 5%-8% and 6%-12%), and hepatic artery/portal vein ratio (CV, 8%-14% and 10%-15%) measurements of 3 all studied parameters. In contrast, inter-scan agreement was only "slight" to "moderate" (CV, 25%-27%) and "fair" to "moderate" (CV, 19%-24%) for rise time and peak intensity measurements in the hepatic artery and portal vein, respectively. Conclusions-Quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound is reproducible provided that measurements in the hepatic artery are normalized by those in the portal vein.
引用
收藏
页码:1413 / 1420
页数:8
相关论文
共 50 条
  • [21] Reproducibility of Dynamic Contrast-enhanced MR Imaging Response
    Heye, Tobias J.
    Boll, Daniel T.
    RADIOLOGY, 2013, 269 (02) : 621 - 621
  • [22] Dynamic contrast-enhanced ultrasound characteristics of renal tumors: VueBox™ quantitative analysis
    Li, Ning
    Hu, Ziyue
    Liu, Yang
    Ding, Jianmin
    Han, Pengcheng
    Jing, Xiang
    Kan, Yanmin
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2023, 85 (04) : 341 - 354
  • [23] METHOD FELL THE QUANTITATIVE ASSESSMENT OF CONTRAST AGENT UPTAKE IN DYNAMIC CONTRAST-ENHANCED MRT
    HITTMAIR, K
    GOMISCEK, G
    LANGENBERGER, K
    RECHT, M
    IMHOF, H
    KRAMER, J
    MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) : 567 - 571
  • [24] Contrast-enhanced ultrasound for quantitative assessment of portal pressure in canine liver fibrosis
    Zhai, Lin
    Qiu, Lan-Yan
    Zu, Yuan
    Yan, Yan
    Ren, Xiao-Zhuan
    Zhao, Jun-Feng
    Liu, Yu-Jiang
    Liu, Ji-Bin
    Qian, Lin-Xue
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (15) : 4509 - 4516
  • [25] Acute Outflow Obstruction of Hepatic Veins in Rabbits: Quantitative Analysis of Hepatic Perfusion on Contrast-Enhanced Ultrasound
    Kim, Kyoung Won
    Kim, Pyo Nyun
    Shin, Ji Hoon
    Shin, Dong Ho
    Jeong, Woo Kyoung
    Won, Hyung Jin
    Shin, Yong Moon
    Lee, Won Jae
    Lee, Moon Gyu
    Song, Gi-Won
    Hwang, Shin
    Lee, Sung-Gyu
    LIVER TRANSPLANTATION, 2010, 16 (06) : S157 - S157
  • [26] Quantitative assessment of placental perfusion by contrast-enhanced ultrasound in macaques and human subjects
    Roberts, Victoria H. J.
    Lo, Jamie O.
    Salati, Jennifer A.
    Lewandowski, Katherine S.
    Lindner, Jonathan R.
    Morgan, Terry K.
    Frias, Antonio E.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 214 (03) : 369.e1 - 369.e8
  • [27] Contrast-enhanced ultrasound for quantitative assessment of portal pressure in canine liver fibrosis
    Lin Zhai
    Lan-Yan Qiu
    Yuan Zu
    Yan Yan
    Xiao-Zhuan Ren
    Jun-Feng Zhao
    Yu-Jiang Liu
    Ji-Bin Liu
    Lin-Xue Qian
    World Journal of Gastroenterology, 2015, 21 (15) : 4509 - 4516
  • [28] Diagnosis of Hepatic Hydatid Cysts by Contrast-Enhanced Ultrasound
    dos Santos, Vitorino Modesto
    Modesto dos Santos, Lister Arruda
    ULTRASCHALL IN DER MEDIZIN, 2020, 41 (06): : 699 - +
  • [29] Contrast-enhanced ultrasound (CEUS) appearance of hepatic myelolipoma
    Menozzi G.
    Maccabruni V.
    Marini G.
    Froio E.
    Garlassi E.
    Journal of Ultrasound, 2016, 19 (1) : 61 - 65
  • [30] Contrast-enhanced ultrasound in diagnosis of primary hepatic angiosarcoma
    Wenwu Ling
    Tingting Qiu
    Lin Ma
    Chuanfen Lei
    Yan Luo
    Journal of Medical Ultrasonics, 2017, 44 : 267 - 270