Detection of gadolinium deposition in cortical bone with ultrashort echo time T1mapping: an ex vivo study in a rabbit model

被引:2
|
作者
Zhao, Kaixuan [1 ,2 ]
Li, Shisi [3 ]
Yi, Peiwei [1 ,2 ]
Guo, Yihao [1 ,2 ]
Yu, Qinqin [3 ]
Zhu, Cuiling [3 ]
Feng, Qianjin [1 ,2 ]
Du, Jiang [4 ]
Zhang, Xiaodong [3 ]
Feng, Yanqiu [1 ,2 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou 510515, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou, Peoples R China
[3] Southern Med Univ, Affiliated Hosp 3, Dept Med Imaging, Guangzhou 510515, Peoples R China
[4] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
基金
中国国家自然科学基金;
关键词
Gadolinium; Contrast media; Cortical bone; Magnetic resonance imaging; DEEP CEREBELLAR NUCLEI; MAGNETIC-RESONANCE; CONTRAST AGENTS; DENTATE NUCLEUS; IN-VIVO; RETENTION; BRAIN; MRI; TISSUE; RELAXOMETRY;
D O I
10.1007/s00330-020-07258-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To investigate the capacity of ultrashort echo time (UTE) T(1)mapping to non-invasively assess gadolinium deposition in cortical bone after gadolinium-based contrast agent (GBCA) administration. Methods Twenty-eight New Zealand rabbits (male, 3.0-3.5 kg) were randomly allocated into control, macrocyclic, high-dose macrocyclic, and linear GBCA groups (n= 7 for each group), and respectively given daily doses of 0.9 ml/kg bodyweight saline, 0.3 mmol/kg bodyweight gadobutrol, 0.9 mmol/kg bodyweight gadobutrol, and 0.3 mmol/kg bodyweight gadopentetate dimeglumine for five consecutive days per week over a period of 4 weeks. After a subsequent 4 weeks of recovery, the rabbits were sacrificed and their tibiae harvested. T(1)value of cortical bone was measured using a combination of UTE actual flip angle imaging and variable repetition time on a 7T animal scanner. Gadolinium concentration in cortical bone was measured using inductively coupled plasma mass spectrometry (ICP-MS). Pearson's correlation between R(1)value (R-1= 1/T-1) and gadolinium concentration in cortical bone was assessed. Results Bone T(1)values were significantly lower in the lower-dose macrocyclic (329.2 +/- 21.0 ms,p< 0.05), higher-dose macrocyclic (316.8 +/- 21.7 ms,p< 0.01), and linear (296.8 +/- 24.1 ms,p< 0.001) GBCA groups compared with the control group (356.3 +/- 19.4 ms). Gadolinium concentrations measured by ICP-MS in the control, lower-dose macrocyclic, higher-dose macrocyclic, and linear GBCA groups were 0.04 +/- 0.02 mu g/g, 2.60 +/- 0.48 mu g/g, 4.95 +/- 1.17 mu g/g, and 13.62 +/- 1.55 mu g/g, respectively. There was a strong positive correlation between R(1)values and gadolinium concentrations in cortical bone (r= 0.73,p< 0.001). Conclusions These results suggest that UTE T(1)mapping has the potential to provide a non-invasive assessment of gadolinium deposition in cortical bone following GBCA administration.
引用
收藏
页码:1569 / 1577
页数:9
相关论文
共 50 条
  • [11] Quantification of Human Cortical Bone Bound and Free Water in Vivo with Ultrashort Echo Time MR Imaging: A Model-based Approach
    Abbasi-Rad, Shahrokh
    Rad, Hamidreza Saligheh
    RADIOLOGY, 2017, 283 (03) : 861 - 871
  • [12] Quantifying Temperature-Dependent T1 Changes in Cortical Bone Using Ultrashort Echo-Time MRI
    Han, Misung
    Rieke, Viola
    Scott, Serena J.
    Ozhinsky, Eugene
    Salgaonkar, Vasant A.
    Jones, Peter D.
    Larson, Peder E. Z.
    Diederich, Chris J.
    Krug, Roland
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (06) : 1548 - 1555
  • [13] Quantitative ultrashort echo time MR imaging of knee osteochondral junction: An ex vivo feasibility study
    Athertya, Jiyo S.
    Suprana, Arya
    Lo, James
    Lombardi, Alecio F.
    Moazamian, Dina
    Chang, Eric Y.
    Du, Jiang
    Ma, Yajun
    NMR IN BIOMEDICINE, 2024,
  • [14] Ultrashort echo time quantitative susceptibility mapping (UTE-QSM) for detection of hemosiderin deposition in hemophilic arthropathy: A feasibility study
    Jang, Hyungseok
    von Drygalski, Annette
    Wong, Jonathan
    Zhou, Jenny Y.
    Aguero, Peter
    Lu, Xing
    Cheng, Xin
    Ball, Scott T.
    Ma, Yajun
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3246 - 3255
  • [15] Ultrashort Echo Time Bi-Component Analysis of Cortical Bone-A Field Dependence Study
    Li, Shihong
    Chang, Eric Y.
    Bae, Won C.
    Chung, Christine B.
    Gao, Song
    Bao, Shanglian
    Bydder, Graeme M.
    Hua, Yanqing
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1075 - 1081
  • [16] Detection of different kidney stone types: an ex vivo comparison of ultrashort echo time MRI to reference standard CT
    Ibrahim, El-Sayed H.
    Cemigliaro, Joseph G.
    Pooley, Robert A.
    Bridges, Mellena D.
    Giesbrandt, Jamie G.
    Williams, James C.
    Haley, William E.
    CLINICAL IMAGING, 2016, 40 (01) : 90 - 95
  • [17] Simultaneous Quantitative Susceptibility Mapping of Articular Cartilage and Cortical Bone of Human Knee Joint Using Ultrashort Echo Time Sequences
    Zhang, Ming
    Li, Zhihui
    Wang, Hanqi
    Chen, Tongtong
    Lu, Yong
    Yan, Fuhua
    Zhang, Yuyao
    Wei, Hongjiang
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [18] Science to practice: In vivo quantification of cortical bone water with ultrashort echo-time MR imaging: A new parameter to measure bone quality?
    Link, Thomas M.
    RADIOLOGY, 2008, 248 (03) : 705 - 706
  • [19] Evaluation of cortical bone perfusion using dynamic contrast enhanced ultrashort echo time imaging: a feasibility study
    Wan, Lidi
    Wu, Mei
    Sheth, Vipul
    Shao, Hongda
    Jang, Hyungseok
    Bydder, Graeme
    Du, Jiang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (08) : 1383 - 1393
  • [20] A Pilot Study on Feasibility of Ultrashort Echo Time T2*Cartilage Mapping in the Sacroiliac Joints
    Wong, Tony T.
    Quarterman, Patrick
    Phuong Duong
    Rasiej, Michael J.
    Wang, Runsheng
    Jaramillo, Diego
    Jambawalikar, Sachin R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (05) : 717 - 721