Detection of gadolinium deposition in cortical bone with ultrashort echo time T1mapping: an ex vivo study in a rabbit model

被引:2
|
作者
Zhao, Kaixuan [1 ,2 ]
Li, Shisi [3 ]
Yi, Peiwei [1 ,2 ]
Guo, Yihao [1 ,2 ]
Yu, Qinqin [3 ]
Zhu, Cuiling [3 ]
Feng, Qianjin [1 ,2 ]
Du, Jiang [4 ]
Zhang, Xiaodong [3 ]
Feng, Yanqiu [1 ,2 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou 510515, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou, Peoples R China
[3] Southern Med Univ, Affiliated Hosp 3, Dept Med Imaging, Guangzhou 510515, Peoples R China
[4] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
基金
中国国家自然科学基金;
关键词
Gadolinium; Contrast media; Cortical bone; Magnetic resonance imaging; DEEP CEREBELLAR NUCLEI; MAGNETIC-RESONANCE; CONTRAST AGENTS; DENTATE NUCLEUS; IN-VIVO; RETENTION; BRAIN; MRI; TISSUE; RELAXOMETRY;
D O I
10.1007/s00330-020-07258-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To investigate the capacity of ultrashort echo time (UTE) T(1)mapping to non-invasively assess gadolinium deposition in cortical bone after gadolinium-based contrast agent (GBCA) administration. Methods Twenty-eight New Zealand rabbits (male, 3.0-3.5 kg) were randomly allocated into control, macrocyclic, high-dose macrocyclic, and linear GBCA groups (n= 7 for each group), and respectively given daily doses of 0.9 ml/kg bodyweight saline, 0.3 mmol/kg bodyweight gadobutrol, 0.9 mmol/kg bodyweight gadobutrol, and 0.3 mmol/kg bodyweight gadopentetate dimeglumine for five consecutive days per week over a period of 4 weeks. After a subsequent 4 weeks of recovery, the rabbits were sacrificed and their tibiae harvested. T(1)value of cortical bone was measured using a combination of UTE actual flip angle imaging and variable repetition time on a 7T animal scanner. Gadolinium concentration in cortical bone was measured using inductively coupled plasma mass spectrometry (ICP-MS). Pearson's correlation between R(1)value (R-1= 1/T-1) and gadolinium concentration in cortical bone was assessed. Results Bone T(1)values were significantly lower in the lower-dose macrocyclic (329.2 +/- 21.0 ms,p< 0.05), higher-dose macrocyclic (316.8 +/- 21.7 ms,p< 0.01), and linear (296.8 +/- 24.1 ms,p< 0.001) GBCA groups compared with the control group (356.3 +/- 19.4 ms). Gadolinium concentrations measured by ICP-MS in the control, lower-dose macrocyclic, higher-dose macrocyclic, and linear GBCA groups were 0.04 +/- 0.02 mu g/g, 2.60 +/- 0.48 mu g/g, 4.95 +/- 1.17 mu g/g, and 13.62 +/- 1.55 mu g/g, respectively. There was a strong positive correlation between R(1)values and gadolinium concentrations in cortical bone (r= 0.73,p< 0.001). Conclusions These results suggest that UTE T(1)mapping has the potential to provide a non-invasive assessment of gadolinium deposition in cortical bone following GBCA administration.
引用
收藏
页码:1569 / 1577
页数:9
相关论文
共 50 条
  • [1] Detection of gadolinium deposition in cortical bone with ultrashort echo time T1 mapping: an ex vivo study in a rabbit model
    Kaixuan Zhao
    Shisi Li
    Peiwei Yi
    Yihao Guo
    Qinqin Yu
    Cuiling Zhu
    Qianjin Feng
    Jiang Du
    Xiaodong Zhang
    Yanqiu Feng
    European Radiology, 2021, 31 : 1569 - 1577
  • [2] Evaluation of gadolinium deposition in cortical bone using three-dimensional ultrashort echo time quantitative susceptibility mapping: A preliminary study
    Zhang, Xiaodong
    Zhou, Beibei
    Chen, Yanjun
    Cai, Zhenyu
    Guo, Yihao
    Wei, Zhao
    Li, Shisi
    Feng, Yanqiu
    Sedaghat, Sam
    Jang, Hyungseok
    NMR IN BIOMEDICINE, 2024, 37 (01)
  • [3] A Feasibility Study of Ultrashort Echo Time Imaging of Cortical Bone at 0.35 T
    Huang, Yuli
    Du, Yiping P.
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (07) : 1409 - 1414
  • [5] Cortical bone water: In vivo quantification with ultrashort echo-time MR imaging
    Techawiboonwong, Aranee
    Song, Hee Kwon
    Leonard, Mary B.
    Wehrli, Felix W.
    RADIOLOGY, 2008, 248 (03) : 824 - 833
  • [6] Classification of Coronary Atherosclerotic Plaques Ex Vivo With T1, T2, and Ultrashort Echo Time CMR
    Karolyi, Mihaly
    Seifarth, Harald
    Liew, Gary
    Schlett, Christopher L.
    Maurovich-Horvat, Pal
    Stolzmann, Paul
    Dai, Guangping
    Huang, Shuning
    Goergen, Craig J.
    Nakano, Masataka
    Otsuka, Fumiyuki
    Virmani, Renu
    Hoffmann, Udo
    Sosnovik, David E.
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (04) : 466 - 474
  • [7] Ultrashort Echo Time (UTE) MRI porosity index (PI) and suppression ratio (SR) correlate with the cortical bone microstructural and mechanical properties: Ex vivo study
    Jerban, Saeed
    Ma, Yajun
    Alenezi, Salem
    Moazamian, Dina
    Athertya, Jiyo
    Jang, Hyungseok
    Dorthe, Erik
    Dlima, Darryl
    Woods, Gina
    Chung, Christine B.
    Chang, Eric Y.
    Du, Jiang
    BONE, 2023, 169
  • [8] Towards assessing and improving the reliability of ultrashort echo time quantitative magnetization transfer (UTE-qMT) MRI of cortical bone: In silico and ex vivo study
    Shin, Soo Hyun
    Moazamian, Dina
    Tang, Qingbo
    Jerban, Saeed
    Ma, Yajun
    Du, Jiang
    Chang, Eric Y.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, : 983 - 992
  • [9] Ultrashort Echo Time MRI of Cortical Bone at 7 Tesla Field Strength: A Feasibility Study
    Krug, Roland
    Larson, Peder Eric Zufall
    Wang, Chunsheng
    Burghardt, Andrew J.
    Kelley, Douglas A. C.
    Link, Thomas M.
    Zhang, Xiaoliang
    Vigneron, Daniel B.
    Majumdar, Sharmila
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (03) : 691 - 695
  • [10] Detecting stress injury (fatigue fracture) in fibular cortical bone using quantitative ultrashort echo time-magnetization transfer (UTE-MT): An ex vivo study
    Jerban, Saeed
    Ma, Yajun
    Nazaran, Amin
    Dorthe, Erik W.
    Cory, Esther
    Carl, Michael
    D'Lima, Darryl
    Sah, Robert L.
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2018, 31 (11)