Solid phase extraction of halogenated, organophosphorus and nitrogen-containing pesticides from river water samples. Analytical quality parameters.

被引:0
|
作者
Baez, ME [1 ]
Navarro, S [1 ]
Solar, A [1 ]
机构
[1] Univ Chile, Fac Ciencias Quim & Farmaceut, Dept Quim Inorgan & Analit, Santiago, Chile
来源
关键词
solid phase extraction; pesticide residue analysis; river water; matrix effects; performance characteristics;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A study of matrix effects arising from river water samples using C18 SPE columns in the determination of 38 pesticides having different chemical properties is presented. Recoveries from river water samples of different origin and the influence of prefiltration step, pH and ionic strength were tested. A calibration equation for the extraction method was calculated by using the statistical method of linear regression, the independent variable being the amount of analyte added and the dependent variable, the amount of recovered analyte. Extractions were carried out in waters spiked with 65 to 1600 ng L-1 of organophosphorus and nitrogen-containing pesticides, and with 12.5 to 320 ng L-1 of halogenated pesticides. Only trifluralin, captan, aldrin, tri-allate, alpha-BHC, gamma-BHC, and azinphos-methyl behavior could not be described through a linear relationship due to low precision and, possibly, to interferences caused by the matrix sample. Linearity, analytical sensitivity, precision and limit of detection were established for 31 compounds. Slope values in the regression equation ranged from 0.68 to 0.98, the exception being amitraz (0.43), dieldrin (0.51), and 4,4' DDT (0.58), which accounted for losses produced in the extraction process. Systematic errors were detected for most of the compounds and they could be corrected by using the calibration data obtained for the whole analytical process. The detection limits established through the model in most of the cases were lower than the maximum allowed limit for waters by the European Union (100 ng L-1), ranging from 7 to 21 ng L-1 for pesticides determined by GC-ECD, and from 20 to 102 ng L-1 (except triadimefon, 220), for those determined by GC-NPD.
引用
收藏
页码:217 / 226
页数:10
相关论文
共 50 条
  • [41] Sequential solid-phase extraction with cyanopropyl bonded-phase cartridges for trace enrichment of PCBs and chlorinated pesticides from water samples
    Russo, MV
    Goretti, G
    Nevigato, T
    CHROMATOGRAPHIA, 1999, 50 (7-8) : 446 - 452
  • [42] Sequential solid-phase extraction with cyanopropyl bonded-phase cartridges for trace enrichment of PCBs and chlorinated pesticides from water samples
    M. V. Russo
    G. Goretti
    T. Nevigato
    Chromatographia, 1999, 50 : 446 - 452
  • [43] Enhancing the efficiency of polypyrrole-dodecylbenzene sulfonic acid in-tube solid-phase microextraction coating for analysis of nitrogen-containing pesticides in water environments
    Ma, Rong
    Yu, Shuangshuang
    Li, Yafang
    Lin, Yan
    Ma, Xiaodong
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2024, 12
  • [44] Determination of six organophosphorus pesticides in water samples by three-dimensional graphene aerogel-based solid-phase extraction combined with gas chromatography/mass spectrometry
    Sun, P.
    Gao, Y. L.
    Xu, C.
    Lian, Y. F.
    RSC ADVANCES, 2018, 8 (19): : 10277 - 10283
  • [45] Synthesis of a zinc-based metal-organic framework with histamine as an organic linker for the dispersive solid-phase extraction of organophosphorus pesticides in water and fruit juice samples
    Amiri, Amirhassan
    Tayebee, Reza
    Abdar, Abbas
    Sani, Fatemeh Narenji
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1597 : 39 - 45
  • [46] MWCNTs-solid phase extraction combined with ultra-high performance liquid chromatography-tandem mass spectrometry for the determination of eleven organophosphorus pesticides in river water
    Liu, Lin
    Jiang, Yang
    Yong, Li
    Hu, Bin
    Zhu, Lan
    Wang, Yan
    Li, Chaojun
    Feng, Zinan
    Zhou, Dingyou
    Sun, Chengjun
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (08) : 743 - 757
  • [47] Selective solid-phase extraction of organophosphorus pesticides and their oxon-derivatives from water samples using molecularly imprinted polymer followed by high-performance liquid chromatography with UV detection
    Godoy Arias, Paulina
    Martinez-Perez-Cejuela, Hector
    Combes, Audrey
    Pichon, Valerie
    Pereira, Eduardo
    Manuel Herrero-Martinez, Jose
    Bravo, Manuel
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1626
  • [48] Electrosynthesis of a new selective chelating agent for solid phase extraction of Ni(II) from water samples: characterisation and analytical applications
    Aliakbar, Alireza
    Jalali, Mehdi
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (06) : 562 - 578
  • [49] DETERMINATION OF ORGANOPHOSPHORUS AND TRIAZINE PESTICIDES IN GROUND AND DRINKING-WATER BY SOLID-PHASE EXTRACTION AND GAS-CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS OR MASS-SPECTROMETRIC DETECTION
    PSATHAKI, M
    MANOUSSARIDOU, E
    STEPHANOU, EG
    JOURNAL OF CHROMATOGRAPHY A, 1994, 667 (1-2) : 241 - 248
  • [50] 3D graphene-carbon nanotubes-based solid-phase extraction technique combined with GC-MS for the determination of organophosphorus pesticides in water samples
    Sun, Peng
    Liu, Mengyao
    Zhang, Xiaolin
    Yan, Rui
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (09) : 2275 - 2282