The isometry of two different paths for remnant-preserving posterior cruciate ligament reconstruction

被引:14
|
作者
Jung, Ho-Joong [1 ]
Kim, Jin Hong [1 ]
Lee, Han Jun [1 ]
Koo, Seungbum [2 ]
Chang, Seung-Hwan [2 ]
Jung, Young Bok [3 ]
Lee, Sang Hak [4 ]
机构
[1] Chung Ang Univ, Coll Med, Dept Orthoped Surg, Seoul 156756, South Korea
[2] Chung Ang Univ, Sch Mech Engn, Seoul 156756, South Korea
[3] Hyundae Gen Hosp, Namyangju Si, Gyeonggi Do, South Korea
[4] Kyung Hee Univ Hosp Gangdong, Dept Orthoped Surg, Sch Med, Ctr Joint Dis & Rheumatism, Seoul 134727, South Korea
基金
新加坡国家研究基金会;
关键词
Posterior cruciate ligament; Reconstruction; Passage; Isometry; Curvature; POSTEROLATERAL CORNER RECONSTRUCTION; KNEE FLEXION; GRAFT; REPLACEMENT; BUNDLES; TENSION;
D O I
10.1007/s00167-012-2111-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
It is reported that the length of the posterior cruciate ligament (PCL) fibres increases as the knee flexes, and the magnitude of the length change reaches up to 9.8 mm throughout the range of motion, which exceeds the range of failure strain. Therefore, we postulated that a compensatory mechanism must be recruited to overcome this large strain in order to maintain physiologic function as a key component of joint kinematics. Our main objective was to compare the length change pattern for the linear distance between the femoral and tibial tunnels with the length change patterns derived from a real isometer test of different curvatures. We utilized ten intact cadaveric knees and created a vertical femoral tunnel (5 mm medial to the roof of the intercondylar notch and 5 mm proximal from the articular margin) and lateral tibial tunnels (5 mm proximal to the posterior bony ridge on the lateral side of the PCL fibre) and performed a 3D-CT scan at 0A(0), 30A(0), 60A(0), 90A(0), and 120A(0). The distances between the femoral and tibial tunnels were calculated from the 3D coordinates. Real isometry was checked both (1) over the PCL and (2) under the PCL using an isometer with an accuracy of 0.1 mm. The path over the PCL had the longest intra-articular length, followed by the path under the PCL, and the lengths measured by CT, respectively. The path over the PCL had a more curved path compared with the path under the PCL and the lengths measured by CT. The lengths measured by CT showed significantly larger excursion than the real isometer test. The path over the PCL showed the least excursion through the range of motion, followed by the path under the PCL, and the lengths measured by CT, respectively. Our findings suggested that a more curved PCL path has better isometry because the curvature of the PCL compensates for the length change between 0A(0) and 60A(0) flexion. In remnant preservation PCL reconstruction, the passage of graft over the PCL would have increased intra-articular length and better isometry compared with straight under the PCL path. Basic science study.
引用
收藏
页码:1029 / 1035
页数:7
相关论文
共 50 条
  • [41] Evaluation of a behind-remnant approach for femoral tunnel creation in remnant-preserving double-bundle anterior cruciate ligament reconstruction - Comparison with a standard approach
    Koga, Hideyuki
    Muneta, Takeshi
    Yagishita, Kazuyoshi
    Watanabe, Toshifumi
    Mochizuki, Tomoyuki
    Horie, Masafumi
    Nakamura, Tomomasa
    Otabe, Koji
    Sekiya, Ichiro
    KNEE, 2015, 22 (03): : 249 - 255
  • [42] Comparative Study of Graft Healing in 2 Years after "Tension Suspension" Remnant-Preserving and Non-Remnant-Preserving Anatomical Reconstruction for Sherman Type II Anterior Cruciate Ligament Injury
    Sun, Yijia
    Huang, Zirong
    Zhang, Pingquan
    Xie, Huanyu
    Wang, Chen
    Deng, Zhenhan
    Chen, Kang
    Zhu, Weimin
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (03):
  • [43] Analysis of Isometry of the Anterior Cruciate Ligament for Optimal Ligament Reconstruction
    Park, Jung Hong
    Son, Kwon
    Suh, Jeung Tak
    Moon, Byung Young
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2006, 30 (04) : 457 - 464
  • [44] Knee Stability in Remnant-Preserving ACL Reconstruction: Letter to the Editor
    Wang, Ruijia
    Chen, Lingxiao
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2025, 53 (02): : NP3 - NP4
  • [45] Posterior cruciate ligament reconstruction using a septum-preserving technique
    Konrads, Christian
    Doebele, Stefan
    Ateschrang, Atesch
    Hofmann, Valeska
    Ahmad, Sufian S.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2021, 33 (05): : 445 - 455
  • [46] Single-Bundle Anatomical Posterior Cruciate Ligament Reconstruction With Remnant Preservation
    Zhao, Jinzhong
    ARTHROSCOPY TECHNIQUES, 2021, 10 (10): : E2303 - E2310
  • [47] Posterior cruciate ligament tendon graft with reconstruction using hamstring remnant augmentation
    Wang, CJ
    Chan, YS
    Weng, LH
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (11):
  • [48] RECONSTRUCTION OF THE POSTERIOR CRUCIATE LIGAMENT
    MARSHALL, DJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01): : 162 - 162
  • [49] RECONSTRUCTION OF THE POSTERIOR CRUCIATE LIGAMENT
    ERIKSSON, E
    HAGGMARK, T
    JOHNSON, RJ
    ORTHOPEDICS, 1986, 9 (02) : 217 - 220
  • [50] Reconstruction of the posterior cruciate ligament
    Raisbeck, CC
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06): : 885 - 885