High frequency ultrasound tissue characterization and acoustic microscopy of intracellular changes

被引:40
|
作者
Brand, Sebastian [1 ,2 ,5 ]
Weiss, Eike C. [3 ]
Lemor, Robert M. [3 ]
Kolios, Michael C. [1 ,2 ,4 ]
机构
[1] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[2] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M4X 1K9, Canada
[3] Fraunhofer Inst Biomed Tech, St Ingbert, Germany
[4] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[5] Univ Halle Wittenberg, Dept Orthopaed, Q BAM Lab, D-06112 Halle, Germany
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2008年 / 34卷 / 09期
基金
加拿大自然科学与工程研究理事会;
关键词
high frequency ultrasound; acoustic microscopy; viable cells; quantitative ultrasound;
D O I
10.1016/j.ultrasmedbio.2008.01.017
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective of this work is to investigate changes in the acoustic properties of cells when exposed to chemotherapy for monitoring treatment response. High frequency ultrasound spectroscopy (10-60 MHz) and scanning acoustic microscopy (0.9 GHz) were performed on HeLa cells (Ackermann et al. 1954, Masters 2002) that were exposed to the chemotherapeutic agent cisplatin. Ultrasonic radio-frequency data were acquired from pellets containing HeLa cells after exposure to cisplatin to induce apoptosis. Scanning acoustic and laser fluorescence microscopy images were recorded from single HeLa cells exposed to the same drug. Data acquisition in both cases was performed at several time points throughout the chemotherapeutic treatment for up to 27 h. In the high frequency ultrasound investigation, normalized power spectra were calculated within a region-of-interest. A 20 MHz transducer (f-number 2.35) and a 40 MHz transducer (f-number 3) were used for the data collection in the high frequency ultrasound experiments. The backscatter coefficients, integrated backscatter coefficients, mid-band fit and spectral slope were computed as a function of treatment time to monitor acoustical property changes during apoptosis. Acoustic attenuation was measured using the spectral substitution technique at all time points. Spectral parameter changes were detected after 12 h of exposure and coincided with the initiation of cell damage as assessed by optical microscopy. Integrated backscatter coefficients increased by over 100% between 0 h and 24 h of treatment, with small changes in the associated attenuation (similar to 0.1 dB/[MHz cm]). Acoustic microscopy was performed at 0.9 GHz frequency. The cell structure was imaged using staining in laser fluorescence microscopy. All cells showed excellent correspondence between the locations of apoptotic nuclear condensation observed in optical imaging and changes in attenuation contrast in acoustic microscopy images. The time after drug exposure at which such changes occurred in the optical images were coincident with the time of changes detected in the acoustic microscopy images and the high frequency ultrasound experiments.
引用
收藏
页码:1396 / 1407
页数:12
相关论文
共 50 条
  • [41] High-Frequency Acoustic Microscopy Studies of Buried Interfaces in Silicon
    Ramanathan, Shriram
    Semmens, Janet E.
    Kessler, Lawrence W.
    56TH ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE 2006, VOL 1 AND 2, PROCEEDINGS, 2006, : 1865 - +
  • [42] HIGH-FREQUENCY ACOUSTIC MICROSCOPY USING PULSE-COMPRESSION
    NIKOONAHAD, M
    YUE, GQ
    ASH, EA
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (01): : 111 - 111
  • [43] ACOUSTIC MICROSCOPY OF NORMAL AND MYOPATHIC HUMAN MYOCARDIUM - IMPLICATIONS FOR ULTRASONIC TISSUE CHARACTERIZATION
    LINKER, DT
    ANGELSEN, BAJ
    POPP, RL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A211 - A211
  • [44] Multilayer analysis: Quantitative scanning acoustic microscopy for tissue characterization at a microscopic scale
    Raum, K
    Jenderka, KV
    Klemenz, A
    Brandt, J
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (05) : 507 - 516
  • [45] ACOUSTIC AND KINETIC BEHAVIOUR OF DEFINITY IN MICE EXPOSED TO HIGH FREQUENCY ULTRASOUND
    Stapleton, Shawn
    Goodman, Heather
    Zhou, Yu-Qing
    Cherin, Emmanuel
    Henkelman, R. Mark
    Burns, Peter N.
    Foster, F. Stuart
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (02): : 296 - 307
  • [46] Acoustic Characterisation of Individual Targeted Microbubbles with High-Frequency Ultrasound
    Sprague, Michael R.
    Goertz, David E.
    Cherin, Emmanuel
    Karshafian, Raffi
    Foster, F. Stuart
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1092 - 1095
  • [47] Acoustic microscopy for bone characterization
    Kundu, Tribikram
    Jorgensen, Claus
    American Society of Mechanical Engineers, Applied Mechanics Division, AMD, 2000, 240 : 13 - 30
  • [48] Acoustic microscopy for imaging and characterization
    Briggs, GAD
    Kolosov, O
    MRS BULLETIN, 1996, 21 (10) : 30 - 35
  • [49] High-frequency ultrasound miniature transducers for tissue imaging
    Yokosawa, K
    Ito, Y
    Sano, S
    Shinomura, R
    Sato, Y
    ULTRASONIC TRANSDUCER ENGINEERING: MEDICAL IMAGING 1997, 1997, 3037 : 13 - 21
  • [50] Viscoelastic tissue property measurement using high frequency ultrasound
    Liu, Dalong
    Ebbini, Emad S.
    2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 892 - 895